My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5901 23RD DR W 2022 BRIDGEWAYS Plans 2024-03-08
>
Address Records
>
23RD DR W
>
5901
>
BRIDGEWAYS
>
Plans
>
5901 23RD DR W 2022 BRIDGEWAYS Plans 2024-03-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2024 1:49:32 PM
Creation date
3/7/2024 2:19:45 PM
Metadata
Fields
Template:
Address Document
Street Name
23RD DR W
Street Number
5901
Tenant Name
BRIDGEWAYS
Permit
M2205-073
Year
2022
Notes
RTU REPLACEMENTS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MicroMetl Date: I Weight: 88Ibs (US) 39.92kg (Metric) I Part Number: ECD-PRCOBCB-DYDB <br /> RTU: <br /> Submitted to: I Approved by: I Notes: <br /> Economizer-Economizer-Genesis Ultra Low Leak Economizer,Vertical Orientation, Belimo Zip-Single/Multiple Speed Electromechanical,Adjustable Dry Bulb <br /> Sensor, Belimo Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief,All Necessary Panels And Hardware Included. For Differential Return Air Dry <br /> Bulb Sensor Please Order 9901-1619. <br /> Compliant Economizer: <br /> 1. Title 24:Economizers meet California Energy Commission Title 24-2013/2016 prescriptive section 140.4(damper leakage etc.),and mandatory section 120.2.i for Fault Detection <br /> and Diagnostic controls(Zip Economizers BZE1245). <br /> 2. ASHRAE 90.1:Economizers meet ASHRAE 90.1-2013/2016 damper leakage requirements,and meet 2016 Fault Detection and Diagnosis requirements. • <br /> 3. IECC:Economizers meet IECC 2012, IECC 2015,IECC 2018 for outside air,return air,and relief damper(when provided)leakage requirements,and IECC 2015 and IECC 2018 for <br /> Fault Detection and Diagnostic requirements.Note:IECC 2015 and IECC 2018 requires differential return air sensor,which must be ordered separately. <br /> 4. AMCA:Outside air and return air(volume)dampers are AMCA Class 1A rated at 1"w.g.Refer to MicroMetl NS2 catalog sheet on web site for details.Relief air dampers(when <br /> provided)are also AMCA rated.Refer to GR1 series catalog sheet on web site for details. <br /> Features: <br /> • Gear driven design for trouble-free operation,eliminating slippage and binding associated with standard leakage. AIR <br /> • Includes assembled rainhood with aluminum water entrainment filters in the outside air section. tiler. <br /> • Rainhood is sloped for water run-off. +we a <br /> • Power exhaust options available. <br /> • Logic wiring is field supplied and installed between the commercial 2 stage thermostat and HVAC low voltage terminal board. noconrnot `4k. <br /> ownsuornonnt.IIIC.�09 <br /> MicroMetl Corporation <br /> certifies that the models <br /> GR1 and NS2 shown <br /> herein are licensed to bear <br /> the AMCA Seal. • <br /> The ratings shown are <br /> based on tests and <br /> procedures performed in <br /> accordance with AMCA <br /> Publication 511 and <br /> comply with requirements <br /> of the AMCA Certified <br /> Ratings Programs. <br /> The AMCA Certified <br /> Ratings Seal applies <br /> to Air Leakage and Air <br /> Performance ratings. <br /> This Document Is The Property Of MicroMetl Corporation And Is Delivered Upon The Express Condition That The Contents WIN Not Be Disclosed Or Used Without MlcroMeti's Written Consent. Master Revision 0001 A <br /> MlcrotettReserves The Right To Discontinue,Or Change At Any Time,Specifications&Designs Without Any Notice Incumng Obligations. Page Revision 0001 A <br /> Indianapolis_3035 N.Shadeland Ave.,Indianapolis,IN 46226_800.MMC.HVAC••Sparks_905 Southern Way,Sparks,NV 89431_800.884.4MMC••Longview_201 Kodak Blvd.,Longview,TX 75602_903.248.4800 <br />
The URL can be used to link to this page
Your browser does not support the video tag.