My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8702 7TH AVE SE 2022 Plans 2024-03-08
>
Address Records
>
7TH AVE SE
>
8702
>
Plans
>
8702 7TH AVE SE 2022 Plans 2024-03-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2024 7:42:27 AM
Creation date
3/8/2024 7:42:14 AM
Metadata
Fields
Template:
Address Document
Street Name
7TH AVE SE
Street Number
8702
Permit
S2212-003
Year
2022
Notes
PROPOSED ELECTRONIC READER BOARD FOR EMERSON ELEMENTARY
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PIXELS HIGH (AAA) PIXELS WIDE(BBB) PIXEL SPACING (CC) # DETAIL DESCRIPTION <br /> 1 DISPLAY GS6-AAAxBBB-CC(SEE CHART ON TOP LEFT) <br /> 40 125 15.85mm 2 LED COLOR RED,AMBER,OR RGB <br /> 3 ACTIVE AREA 2'15/16" [634]X 6'6" [1981] <br /> 32 100 19.81 mm 4 OVERALL SIZE 2'6-15/16" [786]X 6'9" [2057] <br /> 5 CABINET ALUMINUM&STEEL <br /> 24 75 26.42mm 6 VENTILATION FRONT <br /> 7 ACCESS SERVICE FROM FRONT OF DISPLAY <br /> 8 WEIGHT 126 LBS[58 KG](APPROX) <br /> 9 SHIPPING SHIPPED AS A SINGLE UNIT <br /> 10 DIMENSIONS FEET AND INCHES[MILLIMETERS] <br /> 11 PAINTED SEMI-GLOSS BLACK <br /> STRUCTURAL RATING <br /> 1 DESIGN WIND PRESSURE"P"(CASE A) P<=:100 PSF(ASD) <br /> N <br /> 2 STANDARD/CODE SEE DD4145274 FOR APPLICABLE <br /> ch co co DESIGN CODE <br /> 0 3 ALL CLIP ANGLES MUST BE USED TO MOUNT DISPLAY <br /> Fro N (NI RATING PER SINGLE FACE:FOR SIZING ELEC.SERVICE MAX REQ'D SHOWN <br /> co <br /> Cr) F 120VAC 1PH 50(60Hz 240VAC 1PH 50Hz <br /> o 4 w (2 WIRES+GND) (2 WIRES+GND) <br /> DOMESTIC INTERNATIONAL <br /> o iv ;o TECHNOLOGY COLOR NMATTS SPECIAL ORDER <br /> I LINE 1 AMP 1 <br /> SEE STRUCTURAL NOTE#3 (AMPS) (AMPS) <br /> Q� AND INSTALL NOTE#4 RED 370 3.09 LI1.54 <br /> li n n IT! <br /> GS6 AMBER RGB 370 3.09 1.54 <br /> 566 4.72 2.36 <br /> VENTILATION REQUIREMENTS <br /> 6-1/8" [156] Q O 5" [127] DISPLAY RELIES ON VENTILATION TO FUNCTION PROPERLY.INTAKES, <br /> • <br /> 1 LOCATED AT THE FRONT OF THE DISPLAY,MUST BE- f t AIR AT A TEM ERATURENOG EATER THAN <br /> B120 TODRAWIN <br /> IN ORDER TO ENSURE AMBIENT TEMPERATURE AIRFLOW IS MAINTAINED, <br /> 2 NO PORTION OF THE VENTILATION OPENINGS ALONG THE FRONT <br /> OF THE DISPLAY MAY BE COVERED OR OBSTRUCTED IN ANY WAY. <br /> TOP VIEW INSTALL NOTES <br /> IN ORDER TO PRESERVE THE STRUCTURAL INTEGRITY OF THE DISPLAY <br /> 1 CABINET,THE 90°ANGLE BETWEEN THE CABINET AND THE LIFTEYE MUST <br /> BE MAINTAINED-USING A SPREADER BEAM IS SUGGESTED.ALL EYEBOLTS <br /> MUST BE USED WHEN LIFTING. <br /> 2 1/2"LIFTEYES TO ASSIST WITH DISPLAY INSTALLATION.LIFTEYES MAY NOT <br /> BE USED FOR PERMANENT INSTALLATION.LIFTEYES MAY BE REMOVED. <br /> c i 3 MECHANICAL AND SIGNAL CONNECTIONS OCCUR EXTERNAL TO DISPLAY. <br /> CO co CLIP ANGLE FOR MOUNTING.CLIP ANGLES CAN BE ADJUSTED VERTICALLY <br /> 4 1-3/16"AS NEEDED DURING INSTALLATION.CLIP ANGLE CAN BE WELDED OR <br /> BOLTED TO STRINGER.ALL CLIP ANGLE LOCATION MUST BE USED. <br /> Cfl m 5 DAKTRONICS IS NOT RESPONSIBLE FOR THE MOUNTING HARDWARE OR <br /> a) THE INTEGRITY OF THE MOUNTING STRUCTURE. <br /> a- — N 6 DAKTRONICS IS NOT RESPONSIBLE FOR THE MAIN ELECTRICAL <br /> ao cn SEE INSTALL NOTES#1,#2 DISCONNECT.SEE POWER RATINGS ABOVE. <br /> O N to —1.- 9'1/8" "."— 7 SEE DWG-03097583 FOR SIGNAL& MTG DETAILS <br /> EXHAUST AREA [231,9] <br /> Q Q DO NOT COVER j <br /> SEE VENT NOTE#2 <br /> A <br /> 2'6-15/16" [786] 2'15/16" [634] <br /> OVERALL HEIGHT ACTIVE AREA HEIGHT <br /> SEE INSTALL NOTE#7 , ', ' ( ,r ,4 TT <br /> a,3 n ,,,, . ar;pp py,D, ., 6E,_.,)y�.w.;•..., FO�^'"�&y PERMIT <br /> DAKTRONICS ,- It—V°e L.'s.,� , - Z a 4� " <br /> LIGHT SENSOR ACTIVE AREA WIDTH INTAKE AREA <br /> (DO NOT BLOCK) DO NOT COVER.SEE VENT NOTE#2. RIGHT VIEW <br /> 6'9" [2057] PER CN-117066:UNDER STRUCTURAL RATING-STANDARD/CODE. DAB THIRD ANGLE PROJECTION <br /> 04 8 MAR 21THE CONCEPTS EXPRESSED AND DETAILS DO NOT RE THIS DRAWING <br /> OVERALL WIDTH NOTED TO REFERENCE DD4145274 20965 <br /> ARE CONFIDENTIAL OUT THE EXPRESS. RI NOT REPRODUCE BY <br /> ANY MEANS WITHOUT THE EXPRESS WRITTEN CONSENT OF <br /> 03 16 AUG 2016 PER EC-22282:UPDATED DRAWING LAYOUT DJO • DAKTRONICS,INC.OR ITS WHOLLY OWNED SUBSIDIARIES. <br /> 18434 DAKTRONICB COPYRIGHT 2016 DAKTRONICS,INC.(USA) Illt <br /> FRONT VIEW BAB PROJECT: GALAXY GS6 SERIES <br /> 02 09 MAY 16 UPDATED GALAXY LABEL 18436 TITLE: SHOP DWG,GS6-R,2'7"x6'9"(2x5 MODS) <br /> DATE: 08-MAR-21 DIM UNITS: INCHES[MILLIMETERS] SHEET REV <br /> 01 270CT2015 UPDATED 120/240 LINE AMPS TJW SCALE: 1/15 DO NOT SCALE DRAWING 1 OF 1 05 <br /> REV DATE: BY: DESIGN: TWHITEH JOB NO. FUNC-TYPE-SIZE 3111177 <br /> DRAWN: DOSTRAA P1817 E -07- B <br />
The URL can be used to link to this page
Your browser does not support the video tag.