Laserfiche WebLink
TRAILSIDE VILLAGE APARTMENTS <br />DRAWING INDEX PROJECT DESCRIPTION VICINITY MAP <br />08.10.16 <br />T1.00 GENERAL INFO & VICINITY PLAN. <br />0810.16 <br />T1.01 UNIT INFO <br />07.15.16 <br />SURVEY <br />SURVEY SHEET 1 OF <br />07.15.16 <br />SURVEY SHEET 2 OF 2 <br />CIVIL <br />08.10.16 <br />C000 CIVIL NOTES <br />08.10.16 <br />C100 DEMO AND TESC PLAN <br />08.10.16 <br />C101 DEMO AND TESC PLAN <br />D8.10.16 <br />C200 OVERALL PAVING AND GRADING PLAN <br />D8.10.16 <br />C201 PAVING AND GRADING PLAN <br />D8.10.16 <br />0202 PAVING AND GRADING PLAN <br />08.10.16 <br />C2D3 PAVING AND GRADING PLAN <br />D8.10.16 <br />C204 PAVING AND GRADING PLAN <br />D8.10.16 <br />C205 PAVING AND GRADING PLAN <br />08.10.16 <br />C300 SIGNING AND STRIPING PLAN <br />08.10.16 <br />C301 SIGNING AND STRIPING PLAN <br />08.10.16 <br />C400 CIVIL DETAILS <br />08.10.16 <br />ARCHITECTURAL <br />A7.00 SITE PLAN <br />08.10.16 <br />A1.01 ENLARGED SITE PLAN <br />(BUILDINGS 1319. 1321. 1323, 1325) <br />08.10.16 <br />A1.02 ENLARGED SITE PLAN <br />(BUILDINGS 1302, 1304, 1306, 1308, 1310,1312, 1314) <br />08.10.16 <br />A1.03 ENLARGED SITE PLAN <br />(BUILDINGS 1316. 1318, 1320, 1322,1324) <br />D8.10.16 <br />A1.04 ENLARGED SITE PLAN <br />(BUILDINGS 1315-8, 1319-13, 1321-B, 1323-B, 1325-B) <br />D8.10.16 <br />Al.05 ENLARGED SITE PLAN- COMMUNITY BUILDINGS <br />(BUILDINGS A. B. C) <br />08.10.16 <br />A3.00 PROPOSED FLOOR PLAN: BUILDING TYPE A-1 & A-2 <br />(BUILDINGS 1302,1304, 1306, 13DB, 1312, 1314, 1316, <br />1318, 1319, 1320, 1321.1323. 1324) <br />08.10.16 <br />A3.01 ROOF PLAN: BUILDING TYPE A-1 & A-2 <br />(BUILDINGS 1302, 1304, 1306. 13DB. 1312,1314, 1316, <br />1318, 1319, 1320. 1321, 1323, 1324) <br />08.10.16 <br />A3.02 PROPOSED FLOOR PLAN: BUILDING TYPE B <br />(BUILDINGS 1310,1322,1325) <br />08.10.16 <br />A3.03 ROOF PLAN: BUILDING TYPE B <br />(BUILDINGS 1310, 1322, 1325) <br />08.10.16 <br />A3.04 PROPOSED FLOOR PLAN: BUILDING TYPE C <br />(BUILDINGS 1315-B, 1317-B, 131", 1321-B, 1323-8, <br />132513) <br />08.10.16 <br />A3.05 FLOOR PLAN: COMMUNITY BUILDINGS <br />08.10.16 <br />A320 FLOOR PLAN: ENLARGED 1 BEDROOM UNIT <br />08.10.16 <br />A3.21 FLOOR PLAN: ENLARGED 2 BEDROOM UNIT <br />08.10.16 <br />A322 FLOOR PLAN: ENLARGED 3 BEDROOM UNIT <br />08.10.16 <br />A4.00a DEMOLITION ELEVATION: BUILDING TYPE A-i & A-2 <br />(BUILDINGS: 1302, 1304,1306, 1308, 1312, 1314, 1316, <br />1318. 1319, 1320, 1321, 1323. 1324) <br />08.10.16 <br />A4.00b PROPOSED ELEVATION: BUILDING TYPE A-1&A•2 <br />(BUILDINGS: 1302, 1304, 1306, 1308, 1312, 1314, 1316, <br />1318. 1319. 1320. 1321. 1323, 1324) <br />08.10.16 <br />A4.01a DEMOLITION ELEVATION: BUILDING TYPE B <br />(BUILDINGS: 1310,1322, 1325) <br />08.10.16 <br />A4.01b PROPOSED ELEVATION: BUILDING TYPE B <br />(BUILDINGS: 1310, 1322, 1325) <br />08.10.16 <br />A4.02a DEMOLITION ELEVATION: BUILDING TYPE C <br />(BUILDINGS: 1315-B, 1317-B, 131". 1321-B, 1323-B, <br />1325-8) <br />08.10.16 <br />A4.021, PROPOSED ELEVATION: BUILDING TYPE C <br />(BUILDINGS: 1315-8, 1317-B, 1319-B, 1321-B, 132343, <br />1325-B) <br />08.10.16 <br />A4.03 BUILDING ELEVATION: COMMUNITY BUILDINGA <br />08.10.16 <br />A4.04a BUILDING ELEVATION: COMMUNITY BUILDINGS B & C <br />08.10AS <br />A4.04b BUILDING ELEVATION: COMMUNITY BUILDINGS B & C <br />DATE <br />DRAWING <br />STRUCTURAL <br />07.15.16 <br />S1.00 GENERAL STRUCTURAL NOTES <br />08.10.16 <br />S1.01 KEY PLAN FOR BUILDING TYPES &ADA UNIT LOCATIONS <br />0T.15.16 <br />S2.01a BLDG TYPEA-LVL 1/FOUNDATION& LVL2 FRAMING PLANS <br />07.15.16 <br />S2.01b BLDG TYPE A -ROOF FRAMING PLAN & BLDG 1308 2ND FLR <br />07.15.16 <br />S2.02a BLDG TYPE B LVL 1IFOUNDATION & LVL 2 FRAMING PLANS <br />07.15.16 <br />- ROOF FRAMING PLAN <br />S2.02b BLDG TYPE B: <br />07.15.16 <br />S2.03a BLDG TYPE C - LVL 1IFOUNDATION & LVL 2 FRAMING PLANS <br />07.15.16 <br />S2.03b BLDG TYPE C - ROOF FRAMING PLAN <br />08.10.16 <br />S2.04a BLDG TYPE A-ADA-FNDTN & LVL 2 FRAMING PLAN . LAYOUT 1 <br />0..10.16 <br />52.05a BLDG TYPE A-ADA-FNDTN & LVL 2 FRAMING PLAN •LAYOUT 2 <br />08.10.16 <br />6a BLDG TYPE B-ADA-FNDTN & LVL 2 FRAMING PLAN :LNG <br />S2.01 <br />08.10.16 <br />S2.06b BLDG TYPE B-PAA-FNDTN & LVL2 FRAMING PLAN - LAYOUT 2 <br />07.15:16 <br />S2.07 COMM BLDGS B & C - LVL 1/FNDTN & ROOF FRAMING PLANS <br />07.15.16 <br />S4.00 WOOD FRAMING DETAILS <br />MECHANICAL <br />07.15.16 <br />M1.01 COVERSHEET <br />07.15.16 <br />M1.02 SCHEDULES <br />07-15.16 <br />M4.01 DEMOLITION UNIT PLANS <br />07.15.16 <br />M4.02 DEMOLITION UNIT PLANS <br />07.15.16 <br />M4.03 DEMOLITION UNIT PLANS <br />PLUMBING <br />08.10.18 <br />P1.01 COVER SHEET <br />08.10.16 <br />P7.02 SCHEDULES <br />08.10.16 <br />P2.01 SITE PLAN <br />08.10.16 <br />P3.01 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.02 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.03 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.I 04 BUILDNG FLOOR PLAN <br />08.10.16 <br />P3.05 BUILDNG FLOOR PLAN <br />0B.10.18 <br />P3.06 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.07 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.08 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.09 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.10 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.11 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.12 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.13 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.14 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.15 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.16 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.1T BUILDING FLOOR PLAN <br />08.10.16 <br />P3.18 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.19 BUILDING FLOOR PLAN <br />08.10.16 <br />P320 BUILDING FLOOR PLAN <br />08.10.16 <br />P321 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.22 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.23 BUILDING FLOOR PLAN <br />08.1OA6 <br />P3.24 BUILDING FLOOR PLAN <br />08.10.16 <br />P325 BUILDING FLOOR PLAN <br />08.10.16 <br />P326 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.27 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.28 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.29 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.30 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.31 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.32 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.33 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.34 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.35 BUILDING FLOOR PLAN <br />08.10.16 <br />P3.36 BUILDING FLOOR PLAN <br />08.10.18 <br />P4.01 ENLARGED UNIT PLANS <br />08.10.16 <br />P4.02 ENLARGED UNIT PLANS <br />08.10.16 <br />P4.03 ENLARGED UNIT PLANS <br />08.10.16 <br />P5.01 DETAILS <br />08.10.16 <br />P5.02 DETAILS <br />08.10.16 <br />ASAO STAIR PLAN AND SECTIONS <br />ELECTRICAL <br />08.10.16 <br />A7.00 SCHEDULE: FINISH, WINDOW AND DOOR <br />08.10.16 <br />E1.00 LEGEND & DETAILS <br />08.10'16 <br />AS.01 INTERIOR ELEVATIONS: UNITS <br />08.10.16 <br />E1.01 SITE PLAN - ELECTRICAL <br />07.15.16 <br />A9.10 DETAILS: WINDOWS & SIDING <br />08.10.16 <br />E2.10 ONE BEDROOM UNIT TYPES - ELECTRICAL AND LIGHTING <br />07.15.16 <br />A9.40 DETAILS: FLANGE WINDOW WEATHERVATION DETAILS <br />08.10.16 <br />E2.20 TWO BEDROOM UNIT TYPES- ELECTRICAL AND LIGHTING <br />08.10.16 <br />E2.30 THREE BEDROOM UNIT TYPES- ELECTRICAL AND LIGHTING <br />UNIT SUMMARY <br />RESIDENTIAL STRUCTURES <br />BUILDING ID <br />BUILDING DESCRIPTION <br />STORIES <br />#OF UNITS <br />eLOG UNIT MIX Q#)TYPE) <br />#OF BLDGS <br />HUD BLDG GSF <br />HUD BLDG NLSF <br />A-1 <br />GARDEN STYLE APTS <br />2 <br />12 <br />(4) 1-BR, (8) 2-BR <br />12 <br />9,416 <br />8,532 <br />A-2 <br />GARDEN STYLE APTS <br />2 <br />10 <br />(4)1-BR, (6) 2-BR <br />1 <br />7,738 <br />7,008 <br />B <br />GARDEN STYLE ARTS <br />2 <br />16 <br />1 (4)1-BR, (8) 2-BR <br />3 <br />12,120 <br />10,968 <br />C <br />GARDEN STYLE ARTS <br />2 <br />8 <br />1 (4)1-BR, (8) 2-BR <br />6 <br />7,376 <br />7,376 <br />ACCESSORY STRUCTURES <br />BLDG TYPE (BLDG #) <br />BUILDING DESCRIPTION <br />STORIES <br />#OF BLDGS <br />HUD BLDG GSF <br />^� <br />- -- -' <br />T' <br />_ <br />COMMUNITYA <br />CHILD CARE CENTER <br />I 1 <br />1 <br />3,556 <br />COMMUNITY B <br />BOYS & GIRLS CLUB <br />I 1 <br />1 <br />1,818 <br />COMMUNITY C <br />OFFICE & LAUNDRY <br />1 <br />1 <br />2,274 <br />UNITTYPES <br />UNIT IDENTIFIER <br />BEDRMS <br />BATHRMS <br />GSF <br />NLSF <br />NUMBER <br />TOTAL NLSF <br />TYPE 'A' UNITS <br />HEARING ACCOMODATIONS <br />1-BR <br />1 <br />1 <br />676 <br />609 <br />76 <br />46,284 <br />6 <br />1 <br />2-BR <br />2 <br />1 <br />1 939 <br />1 762 <br />ISO <br />214,3001 <br />7 <br />1 2 <br />3-BR <br />3 <br />2 <br />1 1,005 <br />1 922 <br />24 <br />22,138 <br />0 <br />2 <br />TOTAL: <br />250 <br />162,712 <br />13 (5%OF TOTAL) <br />5(2%OF TOTAL) <br />BUILDING TABULATION <br /># OF RESIDENTIAL BLDGS: 22 <br />IF OF ACCESSORY STRUCTURES: 3 <br />#OF STORIES:2 <br />PARKING TABULATION <br />SURFACE PARKING SPACES: 348 <br />SURFACE HC PARKING SPACES: 14 <br />SURFACE VAN PARKING SPACES: 14 <br />TOTAL CAR/VAN PARKING SPACES: 362 <br />SUMMARY OF VALUES <br />GROSS SF- ALL IMPROVEMENTS: 410,340 <br />GROSS SF - RESIDENTIAL: 402,692 <br />GROSS SF - ACCESSORY: 7,648 <br />GROSS SF- COMMERCIAL (INCLUDED ABOVE): N/A <br />GROSS SF - GARAGE N/A <br />NET LEASABLE SF: 182,712 <br />NUMBER OF UNITS: 250 <br />NUMBER OF NON -RENTABLE UNITS: N/A <br />PROJECT INFORMATION <br />LAND ACREAGE: 14.07 ACRES <br />LAND SQUARE FOOTAGE: 612,766 SF <br />LOCATION: 1300 -100TH PLACE S.E., EVERETT, WA 98208 <br />PARCEL 1: PARCEL NO.280519-001-017-00; " <br />LEGAL DESCRIPTION: SEE SURVEY SHEETI <br />ZONING: R-3 <br />APPLICABLE CODES: <br />2015 IEBC INTERNATIONAL BUILDING CODE (LEVEL 1 ALTERATION) <br />2015 IMC INTERNATIONAL MECHANICAL CODE (DEFERRED PERMIT IF APPLICABLE) <br />2D15 UPC UNIFORM PLUMBING CODE (DEFERRED PERMIT IF APPLICABLE) <br />20151ECC INTERNATIONAL ENERGY CONSERVATION CODE <br />UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) <br />2010 ADA STANDARDS FOR ACCESSIBLE DESIGN <br />CONSTRUCTION TYPE: TYPE V <br />OCCUPANCY: R-2 RESIDENTIAL <br />ACCESSORY USES: B OFFICES; A3 COMM. SPACES <br />Not Included in Our <br />Scope <br />` 1001 <br />� Q�F <br />SUMMARY OF WORK: <br />IN -KIND REPLACEMENT OF INTERIOR DOORS, PLUMBING FIXTURES, ELECTRIC PANELS, CABINETS, APPLIANCES, LIGHTING, <br />HEATERS, AND FINISHES; REPLACEMENT & IMPROVEMENTS TO EXTERIOR SIDING, WINDOWS & INSULATION, ROOFING; UPGRADE <br />OF EXISTING UNITS TO TYPE 'A' (7% OF 250 UNITS =18 TYPE W UNITS); PAINTING OF COMMUNITY BUILDING INTERIOR AND <br />EXTERIOR WALLS, SITE IMPROVEMENTS. <br />GENERAL NOTES <br />1. ALL WORK SHALL COMPLY WITH CODES AND LOCAL ORDINANCES. THESE INCLUDE: 2015 INTERNATIONAL EXISTING BUILDING <br />CODE, 2015 WASHINGTON STATE ENERGY CODE, (AS APPLICABLE) ANSI 117.1. <br />2. CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS AND EXISTING CONDITIONS ON THE JOB BEFORE PROCEEDING AND <br />T <br />E E ARCHITECT. N CASES OF DISCREPANCIES BETWEEN EXISTING CONDITIONS AND THE <br />SHALL REPORT ANY DISCREPANCIES TO THE A CHI . I C S I <br />DRAWINGS, THE CONTRACTOR SHALL OBTAIN DIRECTIONS FROM THE ARCHITECT PRIOR TO PROCEEDING. DIMENSIONS NOTED AS <br />PLUS OR MINUS (R-A) INDICATE UNVERIFIED DISTANCE TO EXISTING REFERENCE AND ARE APPROXIMATE. NOTIFY ARCHITECT <br />IMMEDIATELY OF CONFLICTS OR EXCESSIVE VARIATIONS FROM INDICATED DIMENSION. <br />3. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE DRAWINGS. <br />4. REPETITIVE FEATURES DRAWN OR NOTED ONLY ONCE SHALL BE COMPLETELY PROVIDED AS IF DRAWN OR NOTED IN FULL. <br />5. ALL FRAMING AND INTERIOR PARTITIONS SHALL BE IN ACCORDANCE WITH PLANS AND SPECIFICATIONS. STRUCTURAL DETAILS <br />TAKE PRECEDENCE OVER ARCHITECTURAL WHERE INCONSISTENCIES EXIST, CONTACT ARCHTIECT FOR CLARIFICATION. <br />6. CONTRACTOR SHALL CONSULT PLANS OF ALL TRADES FOR DUCTS, PIPING, CONDUIT AND EQUIPMENT. ALL SHALL VERIFY SIZE <br />OF ALL OPENINGS REQUIRED AND SHALL COORDINATE WITH TRADE REQPRESENTTIVES AS APPLICABLE. VERIFY ALL FIELD <br />DIMENSIONS WITH CONDITIONS FOR ITEMS FURNISHED AND INSTALLED. NOTIFY ARCHITECT IMMEDIATELY WHERE FIELD <br />CONDITIONS VARY OR CONFLICT WITH INDICATED. <br />7. CONTRACTOR TO PROVIDE SHORING AND/OR BRACING AS REQUIRED TO COMPLETE THIS WORK. <br />8. PENETRATIONS FOR CONDUITS, DUCTS AND PIPES SHALL BE FIRE SEALED AND DUCTS FIRE DAMPERED, AS INDICTED AND AS <br />REQUIRED BY INTERNATIONAL BUILONG CODE, AT FIRE ASSEMBLIES. <br />9. THE CONTRACTOR, AT THE COMPLETION OF THIS WORK, SHALL REMOVE ALL DEBRIS RESULTING FROM THE WORK. <br />10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE DONE BY SUBCONTRACTORS TO ADJACENT WORK AND SHALL MAKE <br />GOOD SUCH DAMAGE AT THEIR OWN EXPENSE. CONDITIONS TO BE RETAINED WHICH ARE DAMAGED AS A RESULT OF WORK DONE <br />UNDER THIS CONTRACT SHALL BE REPAIRED AND FINISHED TO MATCH ADJACENT FINISHES. <br />11. ALL FRAMING AND INTERIOR PARTITIONS SHALL BE IN ACCORDNANCE WITH STRUCTURAL ENEGINEER'S NOTES. <br />12. FIRE -STOP WALLS, FLOORS AND FURRED AREAS PER IBC. <br />13. CUTTING AND FINISHING PATCHING OF OPENINGS BY THE RESPECTIVE SUBCONTRACTOR SHALL BE SUPERVISED FOR THE <br />TRADE BEING SERVED BY THE GENERAL CONTRACTOR ALL CUTTING AND PATCHING TO BE IN CLOSE COORDINATION AMONG <br />MECHANICAL AND ELECTRICAL SUBCONTRACTORS. <br />14. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO BECOME THOROUGHLY FAMILIAR WITH ALL DOCUMENTS BEFORE <br />THE INSTALLATION OF THIS WORK; ANY DISCREPANCY BETWEEN THE ARCHITECTURAL AND OTHER CONSULTANT DRAWINGS SHALL <br />BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION AND DIRECTION. <br />15. IF NOT NOTED, DIMENSIONS ARE TO THE FOLLOWING ORDER OF PREFERENCE: <br />1. CENTERLINE OF WOOD, WINDOW OR DOOR <br />2. FACE OF SHEATHING <br />3. CENTERLINE OF STRUCTURE <br />4. FACE OF FINISH MATERIAL <br />16. ALL DIMENSIONING NOTED AS "CLR" ARE CLEAR DIMENSIONS FACE OF FINISH MATERIAL TO FACE OF FINISH MATERIAL. <br />BUILDING PERMIT NUMBERS <br />1)COMMUNITY BUILDING <br />1) COMMUNITY BUILDING B <br />3) COMMUNITY BUILDING C <br />� BUILDING 1302 <br />5) BUILDING 13D4 <br />6) BUILDING 1306 <br />10) BUILDING 1314 <br />11) BUILDING 1316 <br />12) BUILDING 1318 <br />13) BUILDING 1319 <br />17) BUILDING 1323 <br />18) BUILDING 1324 <br />19) BUILDING 1325 <br />22) BUILDING 1319 (B) <br />23) BUILDING 1321 (B) <br />24) BUILDING 1323 (B) <br />25) BUILDING 1325 (B) <br />BRUSKRUD RD <br />PROJECT TEAM <br />OWNER: <br />TRAILSIDE PRESERVATION LIMITED PARTNERSHIP <br />21515 HAWTHORNE BLVD., SUITE 390, TORRANCE, CA 90503-6514 <br />NICHOLAS J. TUFANO DIRECTOR OF CONSTRUCTION <br />PHONE:31D-802.6682 EMAIL: NICK@PRESERVATIONPARTNERS.ORG <br />ARCHITECT: <br />SMRARCHITECTS <br />911 WESTERN AVENUE, #200, SEATTLE, WA 98104 <br />DEAN KRALIOS, PRINCIPAL <br />PHONE: 206-623-1104 EMAIL: DKRALIOS@SMRARCHITECTS <br />MAURICE DIAZ, PROJECT ARCHITECT <br />PHONE: 206-623-1104 EMAIL: MDIAZ@SMRARCHITECTS <br />CIVIL: <br />SITEWISE DESIGN PLLC <br />219 FIRST AVE. S., 9401, SEATTLE WA 98104 <br />MARC ERRICHETTI, PE, LEED AP <br />PHONE: 206.402-4644 EMAIL: MARC@SITEWISEPLLC.COM <br />ELECTRICAL: <br />TRAVIS FITZMAURICE & ASSOCIATES <br />1200 WESTLAKE AVE N #509 SEATTLE WA 98109 <br />KEVIN WARTELLE, PROJECT ENGINEER <br />PHONE: 206-285-7228 EMAIL: KEVIN@TRAVISFITZMAURICE.COM <br />MECHANICAL: <br />SIDER + BYERS ASSOCIATES, INC <br />192 NICKERSON ST, SUITE 300, SEATTLE, WA 98109 <br />DANA FONTES, PROJECT ENGINEER <br />PHONE: 206-285-2966 EMAIL: DANA@SIDERBYERS.COM <br />STRUCTURAL: <br />1. L. GROSS STRUCTURAL ENGINEERS <br />23914 56TH AVE W. SUITE 200, MOUNTLAKE TERRACE, WA 98043-5263 <br />ROBYN MAH, PROJECT ENGINEER <br />PHONE: 206-623-0769 EMAIL: RMAH@ILGROSS.COM <br />SIGNATURES <br />OWNER: TRAILSIDE PRESERVATION LIMITED PARTNERSHIP <br />NICHOLAS J. TUFANO DIRECTOR OF CONSTRUCTION <br />PRINTED NAME TITLE <br />SIGNATURE DATE <br />ARCHITECT: STICKNEY MURPHY ROMINE ARCHITECTS, PLLC <br />DEAN KRALIOS MEMBER <br />PRINTED NAME TITLE <br />DATE <br />CONTRACTOR: WALSH CONSTRUCTION COMPANY II, LLC <br />PRINTED NAME <br />SIGNATURE DATE <br />BONDING COMPANY: TRAVELERS CASUALTY AND SURETY COMPANY OF AMERICA <br />PRINTED NAME TITLE <br />SIGNATURE DATE <br />LENDER COMPANY: PNC BANK, N.A. <br />PRINTED NAME TITLE <br />SMR Architects <br />117 S. Main St., Suite 400 <br />Seattle, WA 98104 <br />PH: 206.623.1104 <br />FX: 206.623.5285 <br />i■i AMAIAIM11 <br />MLAGIR <br />"ART20M" <br />1300 100TH PLACE S.E. <br />EVERETT, WA 98208 <br />preservation <br />partners <br />development <br />21515 hawthome blvd., suite 125 <br />torrance, ca 90503 <br />83T REGISTERED <br />ARCHITECT <br />DEAN A. KRALIOS <br />STATE OF WASHINGTON <br />REVISIONSINOTES <br />NO DATE DESCRIPTION <br />0 4.01.16 50% DD SET <br />1 6.09.16 100% DD SET <br />2 7.15.16 HUD Application <br />3 8.10.16 HUD Application <br />TITLE <br />GENERAL INFO <br />00000 <br />DRAWN <br />MD, DLK <br />CHECKED <br />DAK <br />ISSUE DATE <br />08.10.16 <br />JOB NUMBER <br />16002.00 <br />SHEET NO.: <br />T1.00 <br />SIGNATURE DATE <br />