Task 1: Describe the project during construction <br /> Nature and purpose of the construction project: <br /> Replace existing combination air vacuum and release valves (air-valves), vaults, <br /> and connections to 36" potable water transmission mains. <br /> Adjacent areas,including streams,lakes,wetlands,residential areas,and roadsthat <br /> might be affected by the construction project: <br /> No sensitive areas will be impacted by this construction. Existing air-valves are <br /> located in roadways, shoulders, residential areas, and sidewalks as shown on the <br /> plans. <br /> How upstream drainage areas may affect the site: <br /> Upstream drainage areas are not anticipated to affect any of the individual sites. <br /> Downstream drainage leading from the site to a receiving body of water: <br /> BMP's will be installed to prevent erosion and sediment transport from the air-valve <br /> sites during construction. <br /> Critical areas that receive runoff from the site up to one-quarter mile away: <br /> Several of the project sites are within a quarter mile of tributaries and small <br /> wetlands that contribute to North Creek. There are also some small isolated <br /> wetlands within a quarter mile of some sites. The project sites and quarter mile <br /> radius are shown as the center point and within double red circles on the attached <br /> Special requirements and provisions for working near or within critical areas: <br /> No work will occur within or adjacent to any critical areas. <br /> Areas on the site that have potential erosion problems: <br /> There are no areas with the potential for erosion on the planned air-valve <br /> replacement sites. All areas are in flat previously developed surfacing. <br /> Locations where surface water leaves the site: <br /> No disturbed areas are expected to contribute to surface water runoff. <br /> City of Everett <br /> City of Everett Public Works EVERETT Reviewed for Permit 12/30/2021 <br /> Construction Stormwater Pollution Prevention Plan ."`"'..o. 2 of 6 <br /> (SWPPP) Template for Small Projects <br />
The URL can be used to link to this page
Your browser does not support the video tag.