Laserfiche WebLink
Page 8 of 8 August 12, 2021 <br /> B2210804 Asbesto-Test,Inc. 425-489-4040 <br /> Vacant House Located(a,2611 Rockefeller Ave..Everett, WA 98201 <br /> Beds 1 Style Single Family Residential <br /> Baths 1 Year Built 1920 <br /> Sq.Ft. S30 Year Renovated 1940 <br /> Stories 1 County Snohomish County <br /> Lot Size 3.049 Sq.Ft. APN 00439161000600 <br /> Horne facts updated by county records on Jun 4,2021. <br /> Samples taken are listed with their corresponding analyses.If asbestos is detected,those samples containing asbestos are listed first and noted with the initials"ACM". <br /> Some sample analyses listed may be a representative analysis of individual and separate samplings and analysis of homogenous materials,as prescribed by A.H.E.R.A.guideline. <br /> If,during demolition or renovation,any additional suspect asbestos containing materials are located[may include but not limited to:sheet vinyl flooring,Tile flooring,wall or ceiling texturings <br /> or paints,concrete siding or skirting,cement pipes,cement wallboard,electrical cloth,electrical wiring insulation,thermal paper,wallboard,joint compounds,vinyl wall coverings,spackling <br /> compounds,or any other suspect TSI(Thermal System Insulation)],those materials are presumed Asbestos Containing Materials unless determined to be non-asbestos by laboratory analysis. <br /> Asbesto-Test,Inc.does not guarantee approximations of quantities of ACM,which may be listed with the analyses.It is therefore recommended professional abatement price and/or disposal <br /> quotes be obtained by inquiring as to fees per area of specific ACM material(i.e.sq or In ft,etc.),or by on site assessment. <br /> Any and all materials identified as ACM andlorAACM in this report must be abated prior to disturbance in renovation or demolition. <br /> PLM(polarized light microscopy)has been known to miss asbestos in small percentages of some samples,which contain asbestos,thus negative PLM results cannot be guaranteed.Floor tiles <br /> and wipes should be tested with SEM(scanning electron microscope)or TEM(transmitting electron microscope),to ensure analytical accuracy when asbestos is reported in small percentages <br /> Analytical test method.USEPA 600/R931116**(PLM);WAC 296-62-07753 App.J <br /> **One percent is the USEPA regulatory limit for asbestos in bulk samples. <br /> Kev: "FRIABLE"signifies"Easily Airborne" <br /> ACM signifies"Asbestos Containing Material" <br /> AACM signifies"Assumed Asbestos Containing Material" <br /> CAB signifies"Concrete Asbestos Board" <br /> < signifies"less than" <br /> TSI signifies"Thermal System Insulation" <br /> HVAC signifies"Heating Ventilating Air-Conditioning" <br /> NAD signifies"No Asbestos Detected" <br /> END OF REPORT <br /> ArLynn Hammond, Pres., BSc. <br /> Analytical Chemist, AIHA proficient <br /> AHERA CERT 182060- EXP 7-28-22 <br /> S ;,EPS. . <br /> BBB A-T <br /> NAT-4 Ml-I <br /> 1429 Ave.D.#187,Snohomish,WA 98290 <br /> 425-489-4040J775-665-0420 <br /> www.asbestotest.eom <br />