My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2611 ROCKEFELLER AVE 2024-03-27
>
Address Records
>
ROCKEFELLER AVE
>
2611
>
2611 ROCKEFELLER AVE 2024-03-27
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2024 7:34:07 AM
Creation date
3/18/2024 11:06:33 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2611
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
516
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SW 1/4, SEC. 20, T. 29 N., R.05 E., W.M. <br /> SNOHOMISH COUNTY, WASHINGTON <br /> TYPICAL OFFSET 2-FROM PVC SCH 40 TEE OR ELL \ _ <br /> HARDSCAPE,4"FROM MAXIMUM LATERAL LENGTH(FEET) PVC MANIFOLD LINE. <br /> PVC MAINLINE. - PLANTED AREA. EMITTER FLOW RATE GPH <br /> TYPICAL FPT ADAPTER AND <br /> COMPRESSION COUPLER. I 12"SPACING 18"SPACING 4"SPACING EASY FIT COMPRESSION <br /> DRIPVALVE/FILTER/ PSI 0.6 0.9 0.6 0.9 .6 0.9 - / <br /> ADAPTER. / <br /> REGULATOR. <br /> 3/4"PVC LATERAL I 10 125 20 2 9 1961 175 135 350 171 442 1340 EASY FIT COMPRESSION CO / ORIGIN <br /> PIPE. RAIN BIRD MDCFCOUP. �/ <br /> 30 307 236 434 333 550 422 <br /> 40 350 268 495 380 627 171 <br /> 50 125 96 175 135 218 171 LANDSCAPE <br /> TYPICAL OFFSET 2" 60 125 96 175 135 218 171 DRIPLINE TUBING. <br /> FROM _ I ��OR <br /> LA ERAL R: DRIP VALVE 1031185TH AVE NE <br /> HARDSCAPE,4' POLYETHYLENE OR PVC HEADER /�, OR LATERAL FROM VALVE. <br /> FROM PLANTED MANIFOLD,SIZE AS PER"MAXIMUM SNOHOMISH,WA 98290 <br /> FI ` GRID PRECIPITATION RATES(IN/HR) MAXIMUM FLOW PER ZONEAREA FLOW PER ZONE'CHART. LANDSCAPE DRIPLINE TUBING. F TEL:425.346.1905 <br /> EMITTER FLOW RATE MAX GPM PSI LOSS _LjrPVC MANIFOLD LINETYPICAL EMITTER LATERAL WITH PVC TEE. <br /> COMPRESSIONSPACING SPACING 0.6 0.9 SCHEDULE 40 PVC HEADER SIZE <br /> 1/2" 4.7 GPM 7.7 PSI /� <br /> POLYGON SHAPED "C"SHAPED ODD SHAPED <br /> FITTING. z 1 I 12 12 0.96 .44 3/4" 8.3 GPM 5.6 PSI t r)�FLUSH CAP: RAIN BIRD (� <br /> DRIPLINE SPACING AS y 18 18 0.69 .03 7" 73.5 GPM 4.2 PSI �' MDCFCOUP WITH MDCFCAP. <br /> 24 24 0.28 0.41 �� Va <br /> J NOTED.EMITTERS U.¢ I 1-1/2" 33.9 GPM 2.9 PSI /1-AIR RELIEF VALVE: RAIN BIRD <br /> OFFSET FOR 2" 52.4 GPM 1.9 PSI \rY'�/ F <br /> z TRIANGULAR SPACING. F= AR VALVE KIT, INSTALL AT v <br /> y 1 I LATERAL FLOW PER 100 FT(GPM) poLY PIpE HEADER s¢E HIGH POINT OF SYSTEM. <br /> AIR RELIEF VALVE AT Z w <br /> p HIGH POINT,AS , EMITTER 12" 18" 24" 1/2" 4.7 GPM 8.8 PSI <br /> INDICATED. J I FLOW SPACING SPACING SPACING 3/4" 8.3 GPM 6.3 PSI <br /> r 2 1' 13.5 GPM 4.8 PSI <br /> i w TYPICAL DRIP LINE 0.6 GPH 1.0 GPM .67 GPM .50 GPM 1-1/2" 31.8 GPM 2.9 PSI A <br /> u, A WITH EMITTER A g I 0.9 GPH 1.5 GPM .0 GPM .75 GPM 2" 52.4 GPM 2.2 PSI <br /> SPACING AS NOTED. <br /> J TIE DOWN STAKE AT <br /> qo. I SLOPED CONDITION NOTE: <br /> F ALL TEES, ELLS, AND 1. DRIPLINE LATERALS SHOULD FOLLOW THE CONTOURS OF THE SLOPE STATE <br /> g AT 4' O.C. AT CLAY, I WHENEVER POSSIBLE. WASHINGTON <br /> 3' O.C. AT LOAM, OR 2. INSTALL AIR RELIEF VALVE AT HIGHEST POINT. LICENSED <br /> F 2' O.C. AT SAND. F LANDSCAPEARCHITECT <br /> 3. NORMAL SPACING WITHIN THE TOP �/OF SLOPE, <br /> FLUSH VALVE OR I 4. INSTALL DRIPLINE AT 25%GREATER SPACING AT THE BOTTOM OF >xk-��rsn�-! <br /> CAP AT LOW END, THE SLOPE. . ! <br /> END FEED EXAMPLE AS NOTED. CENTER FEED EXAMPLE I 5. WHEN ELEVATION CHANGE IS 10 FT OR MORE, ZONE THE BOTTOM � KRY TAA.LOWE <br /> ON A SEPARATE VALVE. DOGBONE SHAPED CORNER SHAPED CURVED POLYGON HOURGLASS SHAPED LICENCE NO.1206 <br /> 1 TYPICAL RAIN BIRD DRIPLINE REQUIREMENTS <br /> REVISIONS <br /> N.T.S. FX-IR-RB-DRIP-25 # DESCRIPTION DATE <br /> Wall,fence,or building. 1 CITY COMMENTS 4/12/2021 <br /> 2 CITY COMMENTS 9/28/2021 <br /> 2 <br /> '�C„ Wall mounted controller.Install per <br /> 14 4 manufacturers specHications and <br /> REDUCED PRESSURE BACKFLOW BACKFLOW COVER - �" recommendations(Seeirrigation legend <br /> 5 �� 3 DEVICE AS SPECIFIED. AS SPECIFIED. for controller make and model number <br /> 7 8 GALVANIZED NIPPLES <br /> AND ELL AS REQUIRED. ''/4"knockout for earth ground wire. <br /> 6 9 <br /> 2'PVC electrical conduit for irrigation <br /> 13 valves,master valve,and flow sensor wires. <br /> Optional 3'knockout if more wires a <br /> GALVANIZED UNIONS re neetled. <br /> 12 ¢ Secure conduit to wall using stainless steel <br /> 0 AT EACH SIDE. clamp. <br /> 11 o o GALVANIZED RISERS. +� 11111PVC electrical conduit for electrical power per <br /> 10 `i a oo Ari-j local and national electrical codes. <br /> i <br /> 44"THICK IN. - V PVC electrical conduit for ET sensor. <br /> O FINISH GRADE ®PVC SCH 80 ELL '- CONCRETE PAD. (optional). <br /> Finished grade <br /> COVER SIZE+6' <br /> O LANDSCAPE PRODUCTS JUMBO VALVE BOX O PVC SCH SO NIPPLE(LENGTH AS REQUIRED) LENGTH AND WIDTH. c Uj ? <br /> WITH COVER GALVANIZED ELL AND S <br /> OVALVE ID TAG 10 PVC SCH 80 TEE OR ELL NIPPLE, TYPICAL Q <br /> 11 PVC MAINLINE PVC COUPLER OR <br /> ®30-INCH LENGTH OF COILED WIRE REDUCER AS REQ., TYP. W <br /> O LANDSCAPE PRODUCTS DRIP KIT 12 3-MINIMUM DEPTH OF 3/4"WASHED GRAVEL a <br /> (INCLUDES VALVE,FILTER&PRESSURE 13 PVC SCH 80 STREET ELL A J O <br /> REGULATOR) SERVICE _a SECTION VIEW SIDE VIEW ^ W N <br /> SIDE. Notes: ' O <br /> ©PVC SUPPLY HEADER TO DRIPLINE 14 MANUAL FLUSH POINT MAIN LINE, SIZE 1-Common and controller wire to be bundled using electrical tape at 10'-0"on center. V/ N LL O <br /> CONCRETE THRUST BLOCKS, AS PER PLANS. UU <br /> OPVC SCH 80 FEMALE ADAPTER OR REDUCER 90 LBS. OF CONCRETE EACH. 2-Grounding rods shall be located between 8"-0"to 12'-0"away from the controller.Grounding rods shall be%"in diameter x 8'in length.Connect the grounding W Y Q <br /> rod to the controller using 6 gauge bare copper wire or per the manufacturers specifications.See grounding rod detail. LU /A O <br /> 3-ET Station shall be installed no further than 90'away from the controller and a minimum of 15'off of the ground,out from under any overhead obstructions such J V <br /> as,but not limited to,building overhangs,trees,or utilities. J <br /> DRIP ZONE KIT IN VALVE BOX RP BACKFLOW W/ENCLOSURE WALL MOUNTED CONTROLLER UREANTREE FOUNDATION 0W14 W a o LU <br /> 2 /1 I_`/ OPEN SOURCE FREE TO USE <br /> 3 ,Z` N LLj <br /> NOT TO SCALE FX-IR-LPI-VALV-01 1' FX-IR-FX-BACK-06 1/2"=V-0" FX-IR-FX-CONT-06 W C' <br /> Y - LU <br /> ffl <br /> U `V <br /> O <br /> ouT000R WALL� �O N <br /> RAIN BIRD CONTROLLER: <br /> RAIN BIRD ESP-4M <br /> 3 OUTDOOR WALL MOUNT <br /> SEE WIRING DETAIL <br /> ---- O2 1-INCH PVC SCH 40 CONDUIT <br /> AND FITTINGS FOR VALVE WIRES <br /> o t GRAIN BIRD WR2 WIRELESS SENSOR DRAWINGTITLr <br /> LANDSCAPE PLAN <br /> CONTROLLER INTERFACE <br /> E <br /> rmt <br /> CABLE HARNESS FOR CONTROLLERINTERFACE(30"MAXIMUM) <br /> l�GROUND WIRE TO APPLICANT: <br /> GRG. � GROUNDING GRID <br /> &UNCTION BOX <br /> 0 <br /> 01/2-INCH PVC SCH 40 CONDUIT <br /> To POWER SUPPLY ROCKEFELLER SQUARE,LLC <br /> 2611 ROCKEFELLER AVE. <br /> a 0 i 4 EVERETT,WA 98201 <br /> l'J 2 <br /> DRAWING INFORMATION <br /> NOTES: ODG PROJECT#:20-335 <br /> 1.EOR BEST PERFORMANCE,THE CONTROLLER I DRAWN BY:MY <br /> INTERFACE SHOULD BE INSTALLED AT LEAST FIVE I RED CHECKED BY:KL <br /> FEET ABOVE THE GROUND. I OR GREEN <br /> 2.IT IS RECOMMENDED THAT THE CONTROLLER I BLACK OR <br /> INTERFACE BE INSTALLED AWAY FROM SOURCES OF I WIRES WHITE <br /> ELECTRICAL INTERFERENCE(SUCH AS TRANSFORMERS, I TO HERE ® WIRES DATE= <br /> GENERATORS,PUMPS,FANS,ELECTRICAL METER I TO HERE <br /> BOXES)AND METAL OBJECTS TO MAXIMIZE I <br /> COMMUNICATION RANGE. z <br /> N 0 DECEMBER 29, 2020 <br /> I � I <br /> D WIRELESS RAIN SENSOR(OUTDOOR) 5f1E.f=TNO: <br /> Ns WR2 SERIES CONTROLLER INTERFACE J L 5 <br /> WIRING DETAIL <br /> 1-2 <br /> OF 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.