Laserfiche WebLink
Exception:with the Fire Marshal's approval,tents with a maximum square footage of 4,000 <br /> square feet shall have the minimum ballasting requirements as follows: <br /> • Minimum ballast weight used shall be 1,200 pounds per leg. <br /> • Corner shall have two 1,200 pounds ballast weights in place adjacent to each other. <br /> • Anchor points shall be%2 the distance of the leg height from the tent. <br /> • Tent feet shall be installed on each leg. <br /> Straps/Ropes <br /> Straps shall meet the following requirements: <br /> • Ropes are not acceptable only ratchet nylon webbing straps with tensile strength rating shall be <br /> used to secure all tents. <br /> • All methods of securing straps to anchors shall meet the same or greater working loads as <br /> specified by the manufacture. If manufacturer does not provide working loads, 1,200 pounds or <br /> greater shall be used. <br /> • Webbing straps shall be free of tears or excessive frays. <br /> Permit Fees <br /> Operational Fire Permits for carnivals,fairs, and festivals- https://www.everettwa.gov/306/Fire-Permits <br /> Fire Marshal's Office 425.257.8100 1 everettwa.gov/fire I INFORMATION HANDOUT P-11 11.25.2019 1 Page 3 <br />