Laserfiche WebLink
.j <br /> E3LJEHLER RESIEDEMCE � a a <br /> N <br /> J N°m <br /> J 3-'- <br /> REMODEL <br /> m <br /> REMODEL I' W. <br /> W <br /> U ad <br /> W <br /> a <br /> w L F hWN <br /> ww U N]Nn <br /> om 0>> <br /> GENERAL NOTES SHEET INDEX PROJECT TEAM v a z<h- <br /> ARCHITECTURAL OWNER w Z =f^ <br /> 1.THESE GENERAL NOTES PERTAIN TO WORK DESCRIBED ON ALL CONTRACT DOCUMENTS. GREGORY AND CARY BUEHLER u,w 0 D W N <br /> A0.1 TITLE SHEET 23280 SR 525, a 3 H N <br /> 2.THE CONTRACT DOCUMENTS CONSIST OF THE OWNER CONTRACTOR AGREEMENT,THE CONDITIONS OF CONTRACT A7.1 SITE PLAN GREENBANK,WA 98253 C2BUEHLER@GMAIL.COM F s I 10 O a <br /> (GENERAL,SUPPLEMENTARY,AND OTHER CONDITIONS),THE DRAWINGS,THE SPECIFICATIONS,AND ALL ADDENDA ISSUED A2.0 DEMOLITION PLAN v �/ G Q <br /> PRIOR TO AND ALL MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT. A2.1 FLOOR PLAN GENERAL CONTRACTOR <br /> A2.5 ROOF PLAN ce <br /> 3.CONCEPT ARCHITECTURE,LLC IS THE AUTHOR OF THESE PLANS AND CLAIMS A COPYRIGHT IN THESE PLANS AND THE A3.1 ELEVATIONS TBD PROPER TY INFORMATION o r <br /> DESIGNS CONTAINED IN THESE PLANS.THIS CLAIM IS MADE UNDER TITLE 17 OF THE UNITED STATES CODE AND ALL APPLICABLE A3.2 ELEVATIONS <br /> TREATIES AND FOREIGN LAWS.THESE COPYRIGHTED DRAWING FILES ARE TO BE USED FOR REFERENCE ONLY.CONCEPT <br /> ARCHITECTURE,LLC WILL TAKE NO RESPONSIBILITY FOR ANY CHANGES MADE TO THESE DOCUMENTS BY ANOTHER PARTY AND A4.1 BUILDING SECTIONS 0 <br /> ADDRESS 5613 WEST DR,EVERETT,WA 98203 i 3 <br /> NO LICENSE IS GIVEN FOR TRANSFER OF THESE COPYRIGHTS TO ANOTHER PARTY. A9.1 DETAIL SHEET .N <br /> A9.2 DETAILSHEET ARCHITECTURAL APN 00471700004201 Oz <br /> 4.THE WORK COMPRISES THE COMPLETED CONSTRUCTION REQUIRED BY THE CONTRACT DOCUMENTS AND INCLUDES ALL E2.1 ELECTRICAL PLAN 3. <br /> LABOR NECESSARY TO PRODUCE SUCH CONSTRUCTION,AND ALL MATERIALS AND EQUIPMENT INCORPORATED OR TO BE CONCEPT ARCHITECTURE,LLC. P:(425)377-8786 SIZE 27,878 SF(.64 AC.) z <br /> INCORPORATED IN SUCH CONSTRUCTION. 2615 W.CASINO RD.SUITE 1A <br /> EVERETT,WA 98204 MREIMERS@CONCEPTARCHITECTURE.COM SUBDIVISION HIGHLAND ACRES BILK 000 D-01-LOT 42 g w <br /> 5.SHOP DRAWINGS,PRODUCT DATA AND SAMPLES ARE NOT A PART OF THE CONTRACT DOCUMENTS.THE ARCHITECT WILL ZONE R-1 in i <br /> REVIEW THEM,BUT ONLY FOR CONFORMANCE WITH THE DESIGN CONCEPT OF THE WORK AND WITH THE INFORMATION GIVEN STRUCTURAL ¢ <br /> IN THE CONTRACT DOCUMENTS.THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR ANY DEVIATION FROM <br /> STHE AMPL REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE ARCHITECTS REVIEW OF SHOP DRAWINGS,PRODUCT DATA OR LEHTINEN ENGINEERING P:(425)252-2373 PROJECT DESCRIPTION �0 <br /> 4120 HOYT AVE, - r <br /> 6.THE CONTRACTOR SHALL CAREFULLY STUDY AND COMPARE THE CONTRACT DOCUMENTS AND SHALL AT ONCE REPORT TO EVERETT,WA 98203 HNLENG7@GMAIL.COM p <br /> THE ARCHITECT ANY ERROR,INCONSISTENCY OR OMISSIONS HE MAY DISCOVER.THE CONTRACTOR SHALL PERFORM NO 3:0 <br /> PORTION OF THE WORK AT ANY TIME WITHOUT CONTRACT DOCUMENTS OR,WHERE REQUIRED,APPROVED SHOP DRAWINGS, <br /> PRODUCT DATA OR SAMPLES FOR SUCH PORTION OF THE WORK. A REMODEL INCLUDING TWO NEW DORMERS,FINISHING THE BASEMENT,AND <br /> ¢ <br /> ADDING A NEW DECK ON THE BACK,AND REBUILDING THE EXISTING DECK IN THE <br /> 7.ALL WORK IS TO CONFORM WITH THE CONTRACT DOCUMENTS.DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION IF FRONT. =w <br /> UNABLE TO LOCATE DIMENSIONS FOR ANY ITEM OF WORK,CONSULT WITH THE ARCHITECT BEFORE PROCEEDING WITH <br /> CONSTRUCTION. <w <br /> N <br /> 8.IN THE EVENT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THE CONTRACT DOCUMENTS,THEN a o <br /> THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR CODES <br /> AND SHALL BE REVIEWED BY THE ARCHITECT. z <br /> O¢ <br /> 9.ALL WORK SHALL BE PERFORMED WITHIN STRICT CONFORMANCE TO THE MINIMUM STANDARDS OF THE CURRENT EDITION w <br /> OF THE INTERNATIONAL BUILDING CODE AND ALL APPLICABLE NATIONAL,STATE,AND LOCAL LAWS,REGULATIONS AND 0 <br /> ORDINANCES. BASED ON THE FOLLOWING CODES: 0 <br /> 2018 International Building Code F p <br /> 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL SAFETY DURING CONSTRUCTION,AND ALL WORK SHALL 2018 International Residential Code <br /> 15 <br /> CONFORM TO PERTINENT SAFETY REGULATIONS. 2018 International Mechanical Code ¢¢ <br /> 2018 Washington State Energy Code >zo <br /> 11.THE CONTRACTOR SHALL COORDINATE LOCATIONS OF ANY AND ALL MECHANICAL,TELEPHONE,ELECTRICAL,LIGHTING AND 2018 <br /> In Fire Code o 0 <br /> PLUMBING INCLUDING ALL PIPING,DUCT WORK AND CONDUIT.COORDINATE ALL REQUIRED CLEARANCES FOR INSTALLATION 2018 Uniform Plumbing Code <br /> AND MAINTENANCE OF THE ABOVE EQUIPMENT. O <br /> 2020 National Electrical Code �O <br /> 2018 Washington Amendments o- <br /> 12.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING HIS/HER BEST SKILL AND ATTENTION,HE/SHE SHALL BE 2009 ICC/ANSI At 17.1 w <br /> SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS,METHODS,TECHNIQUES,SEQUENCES AND PROCEDURES AND FOR col <br /> COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. g <br /> w> <br /> ¢a <br /> 13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACTS AND OMISSIONS OF HIS/HER EMPLOYEES,SUBCONTRACTORS ¢O <br /> AND THEIR AGENTS AND EMPLOYEES,AND OTHER PERSONS PERFORMING ANY WORK UNDER A CONTRACT WITH THE z yUj <br /> CONTRACTOR. ¢ 1 <br /> 14.THE CONTRACTOR SHALL PURSUE WORK IN A CONTINUOUS AND DILIGENT MANNER TO INSURE TIMELY COMPLETION OF THE SYMBOL LIST �¢ z o <br /> PROJECT. OCCUPANCYGROUP R3 ¢? LL.I N <br /> 00 <br /> 15.THE CONTRACTOR AT ALL TIMES SHALL KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS OR FLOOR AREA 2,308 S.F. o Q 0) <br /> RUBBISH CAUSED BY HIS/HER OPERATIONS.AT THE COMPLETION OF THE WORK,HE/SHE SHALL REMOVE ALL HIS/HER WASTE NORTH ARROW WOOD FRAMING O= Q <br /> NORTH ASPHALT FULLY SPRINKLERED NO <br /> '^ <br /> ) ¢ <br /> MATERIALS AND RUBBISH FROM AND ABOUT THE PROJECT AS WELL AS ALL HIS/HER TOOLS,CONSTRUCTION EQUIPMENT, (THROUGH MEMBERz v <br /> MACHINERY,AND SURPLUS MATERIALS. CONSTRUCTION TYPE VB ¢ <br /> WOOD FRAMING <br /> BATT INSULATION m Uj <br /> 16.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR PROTECTION OF ALL EXISTING AND PROPOSEDcr <br /> (INTERRUPTED MEMBER) 2Ull12Ull.US2US2USll ?¢ W <br /> PIPING,UTILITIES,STRUCTURES,ADJACENT STREETS,AND IMPROVEMENTS DURING THE PERIOD OF CONSTRUCTION. CORNERS CEILING HEIGHT BRICK o 3o LL W <br /> 17.UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS,THE CONTRACTOR SHALL PROVIDE AND PAY FOR ALL 0;F'0„ SPOT ELEVATION +O_Orr x W <br /> LABOR,MATERIAL,EQUIPMENT,TOOLS,CONSTRUCTION EQUIPMENT,MACHINERY,WATER,HEAT,UTILITIES,TRANSPORTATION, 12 5pppp666, CMU BLOCK LLI <br /> AND OTHER FACILITIES AND SERVICES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. �, LEVEL ELEVATION 3 ROOF SLOPE ¢ cc <br /> 0,_O. <br /> SLOPE ROOF SLOPE PLAN a CONCRETE J F- <br /> 18. WHERE CONFLICTS OCCUR,COORDINATE THE LAYOUT AND EXACT LOCATION OF ALL PARTITIONS,DOORS,TELEPHONES TT <br /> AND ELECTRICAUCOMMUNICATION OUTLETS AND SWITCHES WITH ARCHITECT IN THE FIELD BEFORE PROCEEDING WITH 1 W <br /> CONSTRUCT ON. 2 BUILDING SECTION 3-12 DOOR SYMBOL - _ E.I.F.S. Ill <br /> c2 <br /> 19.WHERE CONFLICT IS ENCOUNTERED BETWEEN THE CONTRACT DOCUMENTS THAT WILL MATERIALLY AFFECT THE QUALITY A9.1 CUT Ae WINDOW SYMBOL GRADE/EARTH CIDOR EXTENT OF THE WORK,SUCH CONFLICT SHALL BE RESOLVED TO THE SATISFACTION OF THE ARCHITECT BEFORE THE 1P m rn <br /> AFFECTED ITEMS AND/OR MATERIALS ARE PURCHASED,FABRICATED AND/OR INSTALLED. 2 VICINITY MAP <br /> WALL SECTION CUT GRAVEL <br /> 20.WHERE PRE MANUFACTURED OR PREFABRICATED ITEMS AND/OR MATERIALS ARE TO BE INSTALLED-THE CONTRACTOR A9.1 12 ACCESSORY SYMBOL <br /> SHALL VERIFY ROUGH OR FINISHED DIMENSIONS IN THE FIELD PRIOR TO PURCHASE OR FABRICATION. W <br /> 2 �72� .,., ^` GYPSUM BOARD PROJECT LOCATION oc <br /> PROPOSED <br /> 21.THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS TO BE FREE FROM DEFECTS FOR A MINIMUM OF ONE DETAIL CALLOUT CONTOUR LINE F- o <br /> YEAR FROM DATE OF FINAL ACCEPTANCE,AND PROMPTLY REMEDY SUCH DEFECTS AND ANY SUBSEQUENT DAMAGE CAUSED A9.1 -72- GYPSUM SHEATHING W <br /> BY THE DEFECTS OR REPAIR THEREOF,AT NO EXPENSE TO THE OWNER.GUARANTEE PERIODS OF GREATER THAN ONE YEAR EXISTING a <br /> CONTOUR LINE <br /> MAY BE REQUIRED AND CONTAINED WITHIN THE CONTRACT DOCUMENTS. 1 H <br /> vi ORIENTED STRAND V -- U <br /> " N <br /> 22.UNLESS OTHERWISE ISE PROVIDED IN THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL SECURE AND PAY FOR THE PROPERTY LINE BOARD ` w <br /> BUILDING PERMIT AND FOR ALL OTHER PERMITS AND GOVERNMENTAL FEES,LICENSES AND INSPECTIONS NECESSARY FOR THE 2 A9.1 4 ELEVATION BUBBLE q o O io <br /> PROPER EXECUTION AND COMPLETION OFTHE WORK. MATCH LINE PLYWOOD SHEATHING Q y <br /> 23.WHERE ANY ITEM AND/OR MATERIAL IS INDICATED IN THE CONTRACT DOCUMENTS,AND NOT NECESSARILY DETAILED IN NAME ----- CENTERLINE RIGID INSULATIONW <br /> EACH SPECIFIC CASE,BUT IS REQUIRED FOR A COMPLETE AND PROFESSIONAL INSTALLATION-SUCH ITEM AND/OR MATERIAL ROOM NAME& c U <br /> SHALL BE PROVIDED AS IF SHOWN AND DETAILED IN FULL.PROVIDE MEANS TO FURNISH AND INSTALL. NUMBER "- SAND/MORTAR/ O z w F <br /> PHONE LINE --`.'`•-`- <br /> (��✓�,✓�J PH�H - '-7�-7• PLASTER <br /> �/-'�l" REVISION CLOUD& G G GAS LINE 7�j%%7/%%////// STEEL 0 0 co o O m <br /> NUMBER L u <br /> L� G <br /> CHANGE IN FLOOR ELECTRICAL LINE STONE �i; f o <br /> TIL' EICARPiT MATERIAL E E ������ ���� �� N U <br /> qA X X FENCE LINE 'IL11Y11.LVJ1J111111LIl 111 TECTUM VJ O F <br /> SSSS SANITARYSEWER ® WOOD FINISH at rt` N R <br /> + 0 - N 6 <br /> GRID LINES TVTV TELEVISION LINE <br /> GLASS 2 - 0 '� <br /> yyW WATER LINE Q N 0 O <br /> n D Q U <br />