My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2501 HOYT AVE 2025-04-15
>
Address Records
>
HOYT AVE
>
2501
>
2501 HOYT AVE 2025-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2025 1:51:31 PM
Creation date
3/20/2024 8:50:55 AM
Metadata
Fields
Template:
Address Document
Street Name
HOYT AVE
Street Number
2501
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' , ' DURO-GUARD°ISO II <br /> Installation: <br /> TABLE 2. THERMAL VALUES <br /> • Panels must be kept dry before,during and THICKNESS* LTTR FLUTE SPANABILITY <br /> after installation. Install only as much insulation inches mm R-VALUE inches mm <br /> as can be covered the same day with 1.00 25 5.60 2.625 67 <br /> completed roofing. 1.50 38 8.50 4.375 111 <br /> • The use of multiple layers of insulation with 1.70 41 9.60 4.375 111 <br /> 1.70 43 9.60 4.375 111 <br /> joints staggered a minimum of 6 inches 2.00 51 11.40 4.375 111 <br /> between layers is recommended to eliminate 2.50 64 14.40 4.375 111 <br /> thermal bridging. 2.70 69 15.60 4.375 111 <br /> 3.00 76 17.40 4.375 111 <br /> • Abut panel edges together and stagger joints of 3.30 84 19.20 4.375 111 <br /> adjacent panels. 3.50 89 20.50 4.375 111 <br /> • Boards must be neatly fitted to roof deck and 3.60 91 21.10 4.375 111 <br /> 4.00 102 23.60 4.375 111 <br /> around penetrations with no gaps greater than *Contact Duro-Last for additional thickness options. <br /> %inch. <br /> • Refer to the appropriate Duro-Last roof system TABLE 3. TYPICAL PHYSICAL PROPERTIES <br /> specification and detail drawings for deck Grade 2 20 psi <br /> preparation and attachment requirements. Compressive ASTM D 1621 (138 kPa) <br /> Strength ASTM C 1289 Grade 3 25 psi <br /> • Precautions must be taken to ensure that new (172 kPa) <br /> concrete decks have fully hydrated and do not Dimensional ASTM D 2126 2%linear change <br /> continue to release moisture. Stability (7 days) <br /> Moisture Vapor ASTM E 96 <1 perm Panel Attachment: Transmission (85.0 ng/Pa•s•mz) <br /> Water <br /> • Panels may be attached to the roof deck using Absorption ASTM C 209 <1%volume <br /> mechanical fasteners, insulation adhesive or Service -40°to 200°F <br /> hot bitumen. It is acceptable to use these Temperature (-40°to 93°C) <br /> products in combination. <br /> totally cover the available deck surface. <br /> Mechanical Attachment • To ensure embedment,the board shall also be <br /> • When installing multiple layers(which may "stepped in"at several points while the bitumen <br /> include insulation, cover boards and thermal is still hot enough to allow positive attachment. <br /> bafflers)it is acceptable to mechanically secure <br /> through all layers. • Maximum panel dimensions are 4 ft.x 4 ft. <br /> • Use fasteners and plates supplied by or • Any roof membrane contaminated with bitumen <br /> approved by Duro-Last, Inc. must be replaced. <br /> Adhesive Attachment Storage: <br /> • Insulation adhesive must be supplied by Duro- • Insulation must be protected from open flame <br /> Last, Inc. Refer to the adhesive's product data and kept dry at all times. <br /> sheet for application guidelines.Acceptable • Factory applied packaging is intended only for <br /> products: protection during transit. Slit or remove the <br /> o Duro-Grip®Insta-Stik'". packaging to prevent accumulation of <br /> o Duro-Grip Olybond®. condensation. <br /> o Duro-Grip Millenium Weather-Tite®. • Store elevated(at least 3 inches)and <br /> o Duro-Grip CR-20. completely covered with a weatherproof <br /> covering such as a tarpaulin. <br /> • Subsequent layers of insulation and approved • Do not use panels which are wet or damaged. <br /> cover boards may be attached with insulation • Refer to PIMA Technical Bulletin No. 109: <br /> adhesive. <br /> Maximum panel dimensions are 4 ft.x 4 ft. Storage and Handling Recommendations for <br /> • Polyiso Roof Insulation for additional guidelines <br /> Hot Bitumen Attachment (www.pima.org). <br /> • When using hot bitumen on concrete decks, Limitations: <br /> priming is necessary. <br /> • Temperature of the bitumen shall be • Duro-Last, Inc.will not be responsible or liable <br /> for any defects or problems related to building <br /> approximately 50° F below the inter-ply hand or roof design by others,to deficiencies in <br /> mopping EVT. construction,to dangerous conditions on the <br /> • The deck shall be dry and care must be taken job site,or to improper storage, handling or <br /> to apply the bitumen in sufficient quantity to 412.1 installation by others. <br /> www.duro-last.cam 2 of 2 800=248-0280 <br /> Duro-Last,'World's Best Roof and Duro-Guard are registered marks owned by Duro-Last,Inc. <br /> Updated:10/31/2013 <br />
The URL can be used to link to this page
Your browser does not support the video tag.