LEGEND <br /> P w �, s a V✓ s, :q;x .*y ^P,-1"*"'-"'--"'-" <br /> ,, a <br /> 15 <br /> T I y 4 frl " 6 ,r °� xIt7w SEE SHEET EOa FOR LEGEND AND ABBREVIATIONS <br /> 1:08 129 SV31-1 TAMPER OS&Y Sprinkler Valve TNE269 D/12 TUNNEL O <br /> 1:09 12F SV31-1 WF PRESSURE Waterflow Pressure Switch with Delay 1E269 C/12 <br /> 1:10 12B SV31-1 WF ISO TAMPER Waterflow Isolation Tamper Switch 1 E269 C/12 <br /> 1:11 12C SV31-3 TAMPER OS&Y Sprinkler Valve TNE269 D/12 TUNNEL <br /> 1:12 12D 0V31-3 WF PRESSURE Waterflow Pressure Switch with Delay 1 E269 C/12 <br /> 1:13 12E SV31-3 WF ISO TAMPER Waterflow Isolation Tamper Switch 1 E269 C/12 <br /> 1:14 130 SV31-5 TAMPER OS&Y Sprinkler Valve TNE270 D/13.5 TUNNEL <br /> 1:15 131 SV31-5 WF PRESSURE Waterflow Pressure Switch with Delay 1 E270 C/13.5 <br /> 1:16 132 SV31-5 WF ISO TAMPER Waterflow Isolation Tamper Switch 1E270 C/13.5 SYSTEM SEQUENCE OF OPERATION <br /> 1:17 133 SV31-7 TAMPER OS&Y Sprinkler Valve TNE270 D/13.5 TUNNEL <br /> 1:18 134 SV31-7 WF PRESSURE <br /> Waterflow Pressure Switch with Delay 1 E270 C/13.5 1. ALARM CONDITION: <br /> 1:19 135 SV31-7 WF ISO TAMPER Waterflow Isolation Tamper Switch 1E270 C/13.5 <br /> 1:20 136 SV31-9 TAMPER OS&Y Sprinkler Valve TNE271 D/15 TUNNEL 1.1 ACTIVATION OF ANY ALARM SHALL CAUSE THE FOLLOWING: <br /> 1:21 137 SV31-9 WF PRESSURE Waterflow Pressure Switch with Delay 1E271 C/15 a. Alarm indicator LED on FACP to illuminate. GENERAL NOTES <br /> 1:22 138 SV31-9 WF ISO TAMPER Waterflow Isolation Tamper Switch 1E271 C/15 b. FACP Internal Sounder to activate. <br /> 1:23 139 SV31-11 TAMPER OS&Y Sprinkler Valve TNE271 D/17 TUNNEL c. Display proper message on FACP to display ALARM POINT LOCATION INFORMATION. <br /> 1:24 13F SV31-11 WF PRESSURE Waterflow Pressure Switch with Delay 1E271 C/17 d. Activate FACP DACT, transmit ALARM signal to Central Station monitoring company. <br /> 1:25 13B SV31-11 WF ISO TAMPER Waterflow Isolation Tamper Switch 1 E271 C/17 <br /> OS&Y Sprinkler Valve TNE271 D/15.5 TUNNEL 2. SUPERVISORY CONDITION: <br /> 1:26 13C SV31-T3 TAMPER P <br /> 1:27 13D SV31-T3 VVF PRESSURE Waterflow Pressure Switch with Delay TNE271 D/15.5 TUNNEL 2.1 ACTIVATION OF ANY SUPERVISORY CONDITION SHALL CAUSE THE FOLLOWING: <br /> 1:28 13E SV31-T3 WF ISO TAMPER Waterflow Isolation Tamper Switch TNE271 D/15.5 TUNNEL a. Supervisory indicator LED on FACP to illuminate. <br /> 1:29 140 SV32-2 TAMPER OS&Y Sprinkler Valve TNE269 D/12 TUNNEL <br /> 1:30 141 SV32-2 WF Waterflow Switch-Vane Type 1 E269 D/12 b. FACP Internal Sounder to activate. <br /> 1:31 142 SV32-8 TAMPER OS&Y Sprinkler valve TNE270 D/14 TUNNEL c. Display proper message on FACP to display SUPERVISORY POINT LOCATION INFORMATION. <br /> d. Activate FACP DACT, transmit SUPERVISORY signal to Central Station monitoring company. <br /> 1:32 143 SV32-8 WF Waterflow Switch-Vane Type 1E270 D/14 <br /> 1:33 144 SV32-10 TAMPER OS&Y Sprinkler Valve TNE271 D/15 TUNNEL 3. TROUBLE CONDITION: <br /> 1:34 145 SV32-10 WF Waterflow Switch-Vane Type 1E271 D/15 <br /> 1:35 146 SV32-12 TAMPER OS&Y Sprinkler Valve TNE271 D/17 TUNNEL 3.1 ACTIVATION OF ANY TROUBLE CONDITION SHALL CAUSE THE FOLLOWING: <br /> 1:36 147 SV32-12 WF Waterflow Switch-Vane Type 1 E271 D/17 a. Trouble indicator LED on FACP to illuminate. <br /> 1:37 148 SV32-T2 TAMPER OS&Y Sprinkler Valve TNE269 D/12.5 TUNNEL b. FACP Internal Sounder to activate. REFERENCE DRAWINGS <br /> 1:38 149 SV32-T2 WF PRESSURE Waterflow Pressure Switch with Delay TNE269 D/12.5 TUNNEL C. Display proper message on FACP to display TROUBLE CONDITION. <br /> 1:39 14F SV32-T2 WF ISO TAMPER Waterflow Isolation Tamper Switch TNE269 D/12.5 TUNNEL d. Activate FACP DACT, transmit TROUBLE signal to Central Station monitoring company. <br /> 1:40 14B SV32-T4 TAMPER OS&Y Sprinkler Valve TNE271 D/15.5 TUNNEL <br /> 1:41 14C SV32-T4 WF PRESSURE Waterflow Pressure Switch with Delay TNE271 D/15.5 TUNNEL <br /> 1:42 14D SV32-T4 WF ISO TAMPER Waterflow Isolation Tamper Switch TNE271 D/15.5 TUNNEL <br /> 1:43 14E UV31-5A WF Waterflow Switch-Vane Type 1 E270 C/13.5 <br /> 1:44 150 MANPULL <br /> R OS&Y Sprinkler Valve 1E270 C/13.5 FIRE ALARM SYSTEM SEQUENCE OF OPERATION <br /> 1:45 151 MAN PULL @FACP 1E269 C.5/13 <br /> 1:46 152 SMK @ FACP 1E269 C.5/13 SCALE: NONE E506-4 <br /> 1:47 153 CO2 SYS GRINDR 1 PNL FA 1E268 Be/16.5 <br /> 1:48 154 CO2 SYS GRINDR 1 PNL TRBL 1E268 Be/16.5 CONSTRUCTION NOTES <br /> 1:49 155 CO2 SYS GRINDR 2 PNL FA 1 E268 Bf/16,5 <br /> 1:50 156 CO2 SYS GRIN DR 2 PNL TRBL 1E268 Bf/16.5 <br /> 1:01 122 SMK ELEV 4 MACH RM Update field/programming description E506-3 D/13 <br /> 1:02 123 SMK ELEV 4 1 ST FLR FRONT Update field/programming description E506-3 D/13 <br /> 1:03 124 SMK ELEV 4 1ST FLR REAR Update field/programming description E506-3 D/13 <br /> 1:04 125 SMK ELEV 4 2ND FLR Update field/programming description E506-3 D/13 <br /> 1:05 126 SMK ELEV 4 3RD FLR FRONT Update field/programming description E506-3 D/13 <br /> 1:06 127 SMK ELEV 4 3RD FLR REAR Update field/programming description E506-3 D/13 <br /> 1:07 128 SMK ELEV 4 TOP OF SHAFT Update field/programming description E506-3 D/13 <br /> ARIES NETLINK POWER SUPPLY AND BATTERY SIZE CALCULATION - 40-31 BUILDING <br /> TOTAL STAND-BY CURRENT PER SYSTEM: 0.367 1 AMPS <br /> 40-31 EAST BUILDING FACP POINTS LIST TOTAL ALARM CURRENT PER SYSTEM: 0.543 AMPS <br /> SCALE: NONE E506-4 ENTER STAND-BY HOURS: 48 HOURS <br /> ENTER ALARM TIME: 10 MINUTES <br /> AMPERE HOUR REQUIRED: 17.73 AH <br /> TOTAL AMP HOUR REQUIRE(DERATING FACTOR 1.2): 22.00 AH <br /> BATTERY SIZE REQUIRED PER SYSTEM(TWO(2)BATTERIES REQUIRED): 22 AH <br /> 2-TIERED MAIN OR EXPANSION ENCLOSURE,MAX.20 AMPS" 15 AMPS <br /> _ EXPANSION ENCLOSURE(S)REQUIRED? YES <br /> BILL OF MATERIALS NUMBER OF ENCLOSURE(MAIN/EXPANSION)REQUIRED: 1 <br /> Part# Item Description Unit Qty- NUMBER OF POWER MANAGEMENT UNIT(PMU)BOARD REQUIRED: 1 <br /> 76-800015-001 ARIES NETLink Multi-Loop DACT Card. ea 1 NUMBER OF POWER SUPPLY UNIT(PSU)REQUIRED: 1 <br /> 84-330002-001 PULL STATION-ADDRESSABLE ea 1 TOTAL TOTAL <br /> DS-PS PHOTO DETECTOR ea 1STANDBY STANDBY ALARM ALARM <br /> No DESCRIPTION QTY (AMPS) (AMPS) (AMPS) (AMPS) <br /> DS-SB STANDARD BASE FOR DS SERIES DETECTORS ea 1 1 MM(WITH KEYBOARD/DISPLAY) 1 0.15830 0.15830 0.30000 0.30000 <br /> 70-417018-001 ADDRESSABLE CONTACT INPUT DEVICE ea 149 2 DIGITAL ALARM COMMUNICATOR TRANSMITTER(DACT) EXPANSION CARD 1 0.02400 0.02400 0.03700 0.03700 <br /> SLA1146 12V 24AH Battery ea 2 3 REMOTE DISPLAY CONTROL MODULE(RDCM) 1 .090000 0.09000 0.09100 0.09100 <br /> 4 SMARTONE PHOTOELECTRIC SMOKE DETECTOR DS-PS 8 0.00015 0.00012 0.00022 0.00176 <br /> 06-SS000689-1 RECORD STORAGE CABINET ea 1 5 SMARTONE CONTACT INPUT MODULE(AL'S,N/0) 44 0.00058 0.02552 O.DOO58 0.02552 <br /> 1000015.00000 SSU-00500-BATTERY CABINET ea 1 6 iPOWER MANAGEMENT UNIT(PMU)BOARD#1,MAX. 10.8 AMPS 1 1 0.07000 1 0.07000 0.09000 0.09000 <br /> TOTALS <br /> BILL OF MATERIALS FIRE ALARM CONTROL PANEL BATTERY CALCULATIONS � Vd"d® <br /> SCALE: NONE E506-4 SCALE: NONE E506-4 <br /> VAI <br /> GOW <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAIJ/ZO 12.28.21 THIS DESIGN AND/OR FIRE ALARM SYSTEM DETAILS B oa.o�.22 <br /> / c SPECIFICATION U APPROVED SHEET SEQUENCE NO. <br /> B SHOP DRAWINGS AGOW/HG 04.07.228®L®�� m T E EVEREff FIRE PANEL REPLACEMENT E506 <br /> APPROVED BY DEPT. DATE <br /> CHECKED <br /> PETE�INAMEN APPROV BUILDING 40-031 <br /> �. �..,,�, APPROVED ELECTRICAL MASTER EVERETT, WA'.DWG NO. 40-031-E506 <br />