Laserfiche WebLink
LEGEND <br /> SEE SHEET EOG FOR LEGEND AND ABBREVIATIONS <br /> J-BOX (TOP OF BEAM) q A <br /> 1"C(TOP OF BEAM) Z 1"C(TOP OF BEAM) <br /> 1 3 13.5 1_1:015 SV31-8 WF ISO TAMPER 1 4 SV31-10 14.5 <br /> WF ISO TAMPER L1018 <br /> 2 WF PD WF D <br /> L1:014 SV31-8 WF PRESSURE 2 2 SV31-10 q <br /> AREA A 2 WF PRESSURE <br /> II 1 A I � � II <br /> GENERAL NOTES <br /> E506-3 FIRE ALARM SYSTEM DETAILS DIAGRAM <br /> UT-FA-40-30/31 <br /> 1 <br /> II 4 S I II <br /> 1_1:025SMK ® FACP MAN PULL ® FACP 1_1 026 o <br /> 3/4"C, 6#14 <br /> REFERENCE DRAWINGS <br /> Ba AN <br /> W N <br /> W <br /> I <br /> CONSTRUCTION NOTES <br /> w I Y Y I C�:> CONNECT ALL MONITORING POINTS, FORMERLY MONITORED <br /> N BY ADT PANEL 59-5-31, TO THIS PANEL. THIS PANEL <br /> WILL BECOME THE BUILDING FACP EVT-FA-40-30/31. <br /> Z PROVIDE LABEL ON PANEL AND COMMUNICATIONS PER <br /> x <br /> 1 = DETAIL 4/E506-1. <br /> a P�:> PROVIDE MONITORING DEVICE ON EXISTING SPRINKLER <br /> RISER. CONNECT TO BUILDING FACP, EVF-FA-40-30/31. <br /> UTILIZE EXISTING INFRASTRUCTURE. PROVIDE ADDITIONAL <br /> CONDUIT AND CONDUCTORS AS REQUIRED. SEE DETAIL <br /> 1/E506-1 FOR INSTALLATION NOTES. <br /> PROVIDE ADDRESSABLE MANUAL PULL STATION. CONNECT <br /> TO BUILDING FACP, EVT-FA-40-30/31. PROVIDE <br /> MRSA CONDUIT AND CONDUCTORS AS REQUIRED. <br /> AEE8 J1 ® PROVIDE ADDRESSABLE SMOKE DETECTOR. CONNECT TO <br /> BUILDING FACP, EVT-FA-40-30/31. PROVIDE CONDUIT <br /> B AND CONDUCTORS AS REQUIRED. <br /> MATCH LINE - SEE DWG 40-031-1E264 <br /> 117 13 15 17 K <br /> i iii <br /> BAS ,E26D ", '1 ,E262 <br /> PARTIAL PLAN VIEW <br /> Ne <br /> SCALE: 1/8"=1'-0" *1E263 •1E264 *tE265 <br /> BD <br /> 1E266 •1E267 1E268 <br /> BF <br /> 6c — 1E269 1E270 1E271 <br /> / INDICATES DRAWING NOT INCLUDED IN SET <br /> KEY PLAN BLDG. 40-031 N <br /> SCALE:NONE <br /> 8' 4' 0 4' 8' 16' <br /> G OW SCALE: 1/8"=1'-O" <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE <br /> ACCEPTABILITYDRAWN DATE SUBTITLE CURRENT REVISIONSYMBOL MTE <br /> A EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 12.28.21 THIS DESIGN AND/OR CHECKEDFIRE ALARM SYSTEM-FIRST FLOOR B 04.07.22 <br /> B SHOP DRAWINGS AGOW HG 04.07.22 SPECIFICATION IS APPROVED SHEET SEQUENCE ND. <br /> / B®E®NG m APPROVED BY DEPT. DATE CHECKED VLE EVERETT FIRE PANEL REPLACEMENT 1 E261 <br /> PETE LINAHEN BUILDING 40-031 C V <br /> G �.. ,"p' APPROVED ELECTRICAL MASTER BUILDING <br /> EVERETT, WA.DWG NO. 40-031-1E261 <br /> i <br />