My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2611 ROCKEFELLER AVE ROCKEFELLER SQUARE 2 2024-04-15
>
Address Records
>
ROCKEFELLER AVE
>
2611
>
ROCKEFELLER SQUARE 2
>
2611 ROCKEFELLER AVE ROCKEFELLER SQUARE 2 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 11:26:42 AM
Creation date
3/29/2024 8:40:35 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2611
Tenant Name
ROCKEFELLER SQUARE 2
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The comments below were generated from this project's Stormwater Reviewers. All questions shall be routed through this project's Public Works Reviewer <br />Thad Newport with City of Everett Permit Services (TNewportPeverettwa.gov). <br />south, into the 24" pipe in California and continues <br />east across Broadway. <br />4 <br />WWHM <br />Make sure the sizing is for 100% of the 10 year <br />The WWHM calculations have been redone to size for <br />RJK <br />Model <br />through the 100 year storm to size per Section 6.10 of <br />100% of the 10yr through 100yr. See revised WWHM <br />Calculations <br />the DCSS (output on page 2 still has the default of <br />calculations at the end of section D (page 27). <br />50% of the 2 year through the 50 year storm). <br />5 <br />Detention <br />Orifice elevation should be 0.5 ft because it is 6" <br />The orifice and riser have been revised. See sheet <br />RJK <br />Design <br />above bottom of facility to allow for sediment <br />C4.0 and WWHM Report at end of section D of the <br />storage. <br />drainage report (page 27). <br />Riser height does not match plans. Recommend 3.5 <br />ft in the model and set top of riser at elevation 109 in <br />the plans, to provide 6" freeboard from top of <br />detention pipe. <br />6 <br />Civil Plans <br />Detail 1, Dwg C4.0 —elevations are called out for the <br />The detention pipe elevations have been revised to <br />RJK <br />2 and 50 year storm, but the design sizing shall be <br />show the 10yr and 100yr elevations. See detail 1/C4.0 <br />based on the 10 yr and 100 yr storm. <br />Detail 4, Dwg C4.0 - The rectangular notch <br />The notch dimensions have been corrected to feet. <br />dimensions are listed in feet in the model and inches <br />See detail 3/C4.0 <br />in this detail. This is CB#2 correct? Revise. <br />Standard plan 415 is shown, not sure where this is <br />being used. There is already a detail (#4) for the flow <br />Standard Plan 415 has been removed. Detail 3/C4.0 <br />restrictor device and they do not match. Revise <br />will be used for the restrictor device. <br />details to clarify what is being provided. <br />CB#1—can this be moved to the ROW line or closer <br />The detention location has been changed to be under <br />to the ROW? <br />the garage. CB#1 is now located within the alley. <br />Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.