Laserfiche WebLink
• <br /> MARK TYPE LO8B <br /> Slot 4 LED <br /> ARCHITECTURAL recessed Linear <br /> LIGHTING' <br /> + A+Capable options indicated <br /> ,,. by this color background, <br /> Ordering Example: SL4L LOP 4FT FLP TG 90CRI 35K 400LMF MINI 277V NLIGHT <br /> Linear Direct Light Source Direct LED <br /> Series Length Plan Total Run Length Fixture Style Ceiling Trim Color Rendering Color Temp <br /> SL4L Slot LED LOP Linear 2FT 2' 7FT 7' RLP,. Regressed Lens FL 5/8"Flange(sheetrock) 80CR1 80CRI 27K* 2700K <br /> Linear Recessed Optimized 3FT 3' 8FT 8' FLP. Flush Lens I TG 9/16"or 15/16"Flat or Inverted Tee 90CR1 90 CRI 30K 3000K <br /> Plan 4FT 4' _FT_ *Specifycontinuouslinear be" irimtes5(sheetrocK) 135K 351/UK 1 <br /> 5FT 5' feet in 1"increments WFL Perimeter Mount,5/8"Flange(Sheetrock) 40K 4000K <br /> EFT 6' (7FT6=7FT 61N) WTG 9/16"Flat or Inverted Tee,Perimeter Mount 5OKn 5000K <br /> .For metal pan,hard woad or otherceiling types consult <br /> factory. <br /> Downlight Color Downlight Color <br /> Direct LED Light Output Direct Distribution Downlight" Rendering Temp Minimum Dimming Level Voltage <br /> 400LMF 400 Lumens per FT I(blank) Standard Distribution J 2DL.,' LED Downlight S8OCRI 80CRI 527K 2700K NODIM Non-Dim 120 120V <br /> 600LMF 600 Lumens per FT WW' Wall Wash Standard S9OCRI 90 CRI 530K 3000K 1 MINI Constant current,dimming to 1%_) 1277 277V) <br /> umensper DLx' LED downlights per 535K 3500K DARK Constant current,dimming to 0.1% 347• 347V <br /> 1000LMF 1000 Lumens per FT Run(3DL,4DL,ectJ 540K 4000K MINI' Constant current,dimming to 5% <br /> LMF°" Pit Lumens per FT(Limitedto 300LMF MINIO" Constantcurrent,dimming to 10% <br /> to 1000LMF in 5OLMF increments) <br /> Finish Emergency Options Control Input Primary Sensor" Secondary Sensor" <br /> (blank) White,textured I(blank) No Emergency (blank) Non-dim" ((blank) Single Zone,No Sensor (blank) No additional zones/sensors <br /> xxx/BLKT Black,textured _E10WLCP' Number of 4ft Emergency I ZT 0 toy] NS Multi-zone,No Sensor Main Zone SN5 Multi-zone,with nosensor in <br /> Section(s)with batterypack SLIGHT nLight enabled PDT" Dual TechnologyOccupancy Sensor,PlR secondaryzone <br /> xxz/SENT Silver,textured ECtO pot Emergency Circuits <br /> SLTAIR2" nLight Air(wireless enabled) and Microphonics Sensor SPOT" Dual TechnologyOccupancy Sensor, <br /> xxx/RALTBD RAI naive knob FIR and Microphonics Sensor <br /> xxx=fillin with the appropnate ceilingECOD*" Luton Hi-Lume digital driver ADC" Daylight Dimming Sensor <br /> SADC" DualTechnolo Occu nc Sensor, <br /> trim.Onlytrimsare painted ECOD2114" Lutron Hi-Lume 2-wire(1% API" Passive Infrared OccupancySensor and 9y Pa y <br /> dimming) Daylight Dimming Sensor PIR and Microphonics Sensor <br /> RALTBD isfor pricing only.Replace SAPI" Passive Infrared Occupancy Sensor <br /> with applicable RAL number and ECOD5*' Lutron5-seriesdigitaldriver APD" Dual TechnologyOccupancy Sensor and <br /> texture when placing order (5%dimming) Daylight Dimming Sensor and Daylight Dimming Sensor <br /> DM. DALI compatible SAPD" DualTechnologyOccupancy Sensor <br /> and Daylight Dimming Sensor <br /> Tertiary Zone Options <br /> (blank) No additional zones/sensors (blank) No Options WL''" Wet Location Listing <br /> INS Multi-zone,with nosensor in CP" Chicago Plenum DPI. Damp Location Listing <br /> 1 tertiary zone USPOM US point of assembly PWS 6'Pre-Wire,3/8'Diameter, <br /> 18Gauge <br /> *Requires longer lead time. <br /> Notes <br /> 1. Supplied with lift and shift lay-in lens. 9. Default battery pack is integral,battery pack will be remote on 2'&3' 14.Requires ZT or SLIGHT Control Input. <br /> 2. Supplied with snap-in lens. (REIOWLCP).Integral battery not available with RLP,WW,sensors or 15.Requires ZT,SLIGHT or NLTAIR2 Control Input. <br /> 3. Wet Location label not available with downlights,regressed lens,or with downtights.Only 1 integral battery pack per unit.CP listing must have 16.Must use 120 volt. <br /> sensor o tions,or PWS.Cannot be installed on vertical surfaces. an integral battery.Remote batteries are not wet location listed,they <br /> p may be used with a wet location fixture is the battery itself is mounted in 17.Must select MINI options. <br /> 4. Not intended for post sheetrock installation. a dry location. 18.MINIO not available with 347,sensors,SLIGHT or NLTAIR2,requires ZT. <br /> 5. Wall Wash not available with downlights,RLP lens and all sensor options. 10.Standard 4'EC section,defaults to end of run.2ft,3ft and 5ft powers 19.Must select MINI.or DARK.Not available with RLP,WW,PDT,ADC or 347, <br /> 6. See notes on page 3,downlights only available with DARK dimming level. entire fixture,6ft powers 3ft EC section. DPL or WL.If with EC,cannot be on individual units,and on runs,the EC <br /> 7. MINS requires ECOo5 Control Input.ECODS only available with MINS 11.Not available with ECOD,ECOD2,ECODS. cannot be on the same section as NLTAIR2. <br /> dimming. 12.Only available with NODIM option. 20.DALI is only available with DARK or MINI.It is not available with sensors <br /> 8. Not available with 2'sections,E1OWLCP or sensors.Only available with 13.Sensors not available with WW,NODIM driver,WL,RLP,downlights or 2'& or downlights. <br /> NODIM or MINI with ZT. 3'units.Not available with 347&SLIGHT together.Default location for 21.CP not available with NLTAIR2. <br /> sensor is the left side of the fixture.For runs the first fixture will include <br /> the sensor. <br /> A+Capable Luminaire <br /> This item is an A+capable luminaire,which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with <br /> simple commissioning. <br /> • All configurations of this luminaire meet the Acuity Brands'specification for chromatic consistency <br /> • This luminaire is part of an A+Certified solution for nLight®control networks when ordered with drivers marked by a shaded background* <br /> • This luminaire is part of an A+Certified solution for nLight control networks,providing advanced control functionality at the luminaire level,when selection <br /> includes driver and control options marked by a shaded background* <br /> To learn more about A+,visit www antitvbrands corn/aulus. <br /> *See ordering tree for details <br /> marklighting.com I 888-834-5684 I ©2013-2021 Acuity Brands Lighting,Inc.All Rights Reserved.We reserve the right <br /> to change design,materials and finish in any way that will not alter installed appearance or reduce function and performance. <br /> Page 2 SLOT 4 LED RECESSED LINEAR 11/11/21 <br />