Laserfiche WebLink
wr <br /> a <br /> MARK Slot 4 LED TYPE L17 <br /> ARCHITECTURAL Recessed Linear <br /> LIGHTI \GT` <br /> + A+Capable options indicated <br /> by this color background. <br /> Ordering Example: SL4L LOP 4FT FLP TG 90CRI 351<4O0LMF MINI 277V NLIGHT <br /> Linear Direct Light Source Direct LED <br /> Series Length Plan Total Run Length Fixture Style Ceiling Trim Color Rendering Color Temp <br /> 5L41 Slot4LED LOP Linear 2FT 2' 7FT 7' RLP" Regressed Lens FL' 5/8"Flange(sheetrock) 80CRI 80CRI 27K* 2700K <br /> Linear Recessed Optimized 3FT 3' 8FT 8' FLP' Flush Lens fro 9/16"or 15/16"Rotor Inverted Tee 90CRI 90 CRI 30K 3000K <br /> Plan MEI _FT_ *Specifycontinuouslinear GB4 Trimless(sheetrock) 135K 35001d <br /> 5FT 5' feet in 1"increments WFL Perimeter Mount,5/8"Flange(Sheetrock) 40K 4000K <br /> EFT 6' (7FT6=7FT 61N) WTG 9/16"Rotor Inverted Tee,Perimeter Mount 50K* 5000K <br /> *For metalpan,hard wood or otherceili gtypescomult <br /> factory. <br /> Downlight Color Downlight Color <br /> Direct LED Light Output Direct Distribution Downlight" Rendering Temp Minimum Dimming Level Voltage <br /> 400LMF 400Lumensper FT (blank) Standard Distribution 2DL'.' LED Downlight S80CRI 80CRI 527K 2700K NODIM Non-Dim 120 120V <br /> I600LMF 600Lumens per I Standard I <br /> l Pe WW' Wall Wash 590CRI 90 CRI 530K 3000K MINI Constant current,dimming to l%I 1277 277V <br /> simnel- auu Lumens perhl DL'` LED downlights per <br /> 535K 3500K DARK Constant current,dimming to 0.1% 347' 347V <br /> 1000LMF 1000 Lumens per FT Run(3DL,4DL,ectJ 540K 4000K MINS' Constant current,dimming to 5% <br /> LMF*" ##Lumens per FT(Limitedto 300LMF MIN10_5 Constant current,dimming to 10% <br /> to 1000LMF in SOLMF increments) <br /> Finish Emergency Options Control Input Primary Sensor" Secondary Sensor" <br /> (blank) White,textured I I(blank) No Emergency I (blank) Non-dim" 1(blank) SingleZone,No Sensor I (blank) No additional zones/sensors <br /> xxx/BLKT Black,textured _EIOWLCP' Numberof4ftEmergency IZT 0 10V I NS Multi-zone,No Sensor Main Zone SNS Multi-zone,with no sensor in <br /> Sections)with batterypack NLIGHT nli htenabied secondaryzone <br /> xzx/SENT Silver,textured EC" #of EmergencyCircuits g PDT" Dual Technology Occupancy Sensor,Pit <br /> zxx/RALTBD J;,41 nauv hnisb NLTAIR2" nLight Air(wireless enabled) and Mkrophonics Sensor SPOT'4 Dual TechnologyOccupancy Sensor, <br /> ECOD*" Luton Hi-Lumedigitaldriver ADCi4 Daylight Dimming Sensor PlR and Microphonics Sensor <br /> non=fill inwiththeappropriate ceiling SADC34 Dual TechnologyOccupancy Sensor, <br /> Vim.Onlytrimsarepainted ECOD2'.." Lutron Hi-Lume2-wire(1% API" Passive Infrared OccupancySensor and <br /> dimming) Daylight Dimming Sensor PIR and Microphonics Sensor <br /> RALTBD isforpdcingonly.Replace SAPI" Passive Infrared Occupancy Sensor <br /> with applicable RAL number and ECOD5*7 Lutron5-seriesdigital driver APO" Dual TechnologyOccupancy Sensor and <br /> texture when plating order (5%dimming) DaylightDimming Sensor and Daylight Dimming Sensor <br /> DALI. DALI compatible SAP)" Dual TechnologyOccupancy Sensor <br /> and Daylight Dimming Sensor <br /> Tertiary Zone Options <br /> (blank) Noadditionalzones/sensors (blank) No Options WL'," Wet Location Listing <br /> TNS Multi-zone,with no sensor in Cl" Chicago Plenum DPL Damp Location Listing <br /> tertiary zone USPOM US pointof assembly PWS 6'Pre-Wire,3/8"Diameter, <br /> 18 Gauge <br /> *Requires longer lead time. <br /> Notes <br /> 1. Supplied with lift and shift lay-in lens. 9. Default battery pack Is integral,battery pack will be remote on 2'&3' 14.Requires ZT or NLIGHT Control Input. <br /> 2. Supplied with snap-in lens. (REIOWLCP).Integral battery not available with RLP,WW,sensors or 15.Requires ZT,NLIGHT or NLTAIR2 Control Input. <br /> 3. Wet Location label not available with downlights,regressed lens,or with downlights.Only 1 integral battery pack per unit.CP listing must have 16.Must use 120 volt. <br /> sensor options,or PWS.Cannot be installed on vertical surfaces. an integral battery.Remote batteries are not wet location listed,they <br /> may be used with a wet location fixture is the battery itself is mounted in 17.Must select MINT options. <br /> 4. Not intended for post sheetrock installation. a dry location. 18.MIN10 not available with 347,sensors,NLIGHT or NLTAIR2,requires ZT. <br /> 5. Wall Wash not available with downlights,RLP lens and all sensor options. 10.Standard 4'EC section,defaults to end of run.2ft,3ft and 5ft powers 19.Must select MINI or DARK.Not available with RLP,WW,PDT,ADC or 347, <br /> 6. See notes on page 3,downlights only available with DARK dimming level. entire fixture,6ft powers 3ft EC section. DPL or WL.If with EC,cannot be on individual units,and on runs,the EC <br /> 7. MINS requires ECODS Control Input.ECODS only available with MINS 11.Not available with ECOD,ECOD2,ECODS. cannot be on the same section as NLTAIR2. <br /> dimming. 12.Only available with NODIM option. 20.DALI is only available with DARK or MINI.It is not available with sensors <br /> 8. Not available with 2'sections,E10WLCP or sensors.Only available with 13.Sensors not available with WW,NODIM driver,WL,REP,downlights or 2'& or downlights. <br /> NODIM or MINT with ZT. 3'units.Not available with 347&NLIGHT together.Default location for 21.CP not available with NLTAIR2. <br /> sensor is the left side of the fixture.For runs the first fixture will include <br /> the sensor. <br /> A+Capable Luminaire <br /> This item is an A+capable luminaire,which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with <br /> simple commissioning. <br /> • All configurations of this Luminaire meet the Acuity Brands'specification for chromatic consistency <br /> • This luminaire is part of an A+Certified solution for nLight®control networks when ordered with drivers marked by a shaded background* <br /> • This luminaire is part of an A+Certified solution for nLight control networks,providing advanced control functionality at the luminaire level,when selection <br /> includes driver and control options marked by a shaded background* <br /> To learn more about A+,visit www acuitvhrands com/aolus. <br /> *See ordering tree for details <br /> marklighting.com I 888-834-5684 I ©2013-2021 Acuity Brands Lighting,Inc.All Rights Reserved.We reserve the right <br /> to change design,materials and finish in any way that will not alter installed appearance or reduce function and performance. <br /> Page 2 SLOT 4 LED RECESSED LINEAR 11/11/21 <br />