Product Specifications <br /> S9X1B040U3PSBA(a) S9X1B040U3PSBA(a) <br /> MODEL S9B1B040U3PSAA MODEL S9B1B040U3PSAA <br /> TYPE Upflow/Horizontal Gauge(Fired) 20 <br /> RATINGS(b) ORIFICES—Main <br /> Input BTUH 40,000 Nat.Gas Qty.—Drill Size 2-45 <br /> Capacity BTUH(ICS)(C)(d) 38,800 LP Gas Qty.—Drill Size 2-56 <br /> Temp.Rise(Min.-Max.) 30-60 GAS VALVE Redundant-One Stage <br /> AFUE(%)S9X1/S9B1(d) 96.0/92.1 PILOT SAFETY DEVICE <br /> BLOWER DRIVE DIRECT Type 120 V SiNi Igniter <br /> Diameter—Width(In.) 11 X 8 BURNERS—Type Multiport Inshot <br /> No.Used 1 Number 2 <br /> Speeds(No.)(e) 9 POWER CONN.—V/Ph/Hz(h) 120/1/60 <br /> CFM vs.in.w.g. See Fan Performance Ampacity(In Amps) 8.8 <br /> Table <br /> Motor HP 1/2 <br /> Max.Overcurrent Protection(Amps) 15 <br /> RPM 1075 <br /> PIPE CONN.SIZE(in.) 1/2 <br /> Volts/Ph/Hz 120/1/60 DIMENSIONS H x W x D <br /> FLA 6.4 Uncrated(In.) 34 x 17-1/2 x 28-3/4 <br /> COMBUSTION FAN—Type Centrifugal Crated(In.) 35-1/2 x 19-1/2 x 30-7/8 <br /> Drive—No.Speeds Direct-1 WEIGHT <br /> Motor HP—RPM 3300 Shipping(Lbs.)/Net(Lbs.) 122/114 <br /> (a) Meets Energy Star <br /> Volts/Ph/Hz 120/1/60 (b) For U.S.applications,above input ratings(BTUH)are up to 2,000 <br /> FLA 0.66 feet,derate 4%per 1,000 feet for elevations above 2,000 feet above <br /> sea level.For Canadian applications,above input ratings(BTUH)are <br /> FILTER—Furnished? No up to 4,500 feet,derate 4%per 1,000 feet for elevations above 4,500 <br /> feet above sea level. <br /> Type recommended High Velocity (_) Central Furnace heating designs are certified to ANSI Z21.47/CSA <br /> Hi Vel.(No.-Size-Thk.) 1—16x25—1 in. 2.3—latest edition. <br /> (d) Based on U.S.government standard tests. <br /> VENT PIPE DIAMETER—Min(in.) 2 Round e) 9 Speed constant torque ECM blower motor <br /> M (g) M Refer to the Vent Length Table in the Installer's Guide. <br /> HEAT EXCHANGER (9) All furnace models have a vent outlet diameter that equals 2 in. <br /> (h) The above wiring specifications are in accordance with National <br /> Type—Fired 409 Stainless Steel Electrical Code;however,installations must comply with local codes. <br /> —Unfired 29-4C Stainless Steel <br /> S9X1 B040U-SUB-1A-EN 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.