Product Specifications <br /> MODEL ^^^°"'^'^" 4YCC4048A1090A F.L.Amps/L.R Amps -.51/3.O7 1.51/3.07 <br /> RATED Volts/PH/Hz 208-230/1/60 208-230/1/60 INDOOR FAN— CONSTANTTORQUE CONSTANT <br /> Performance Cooling TYPE ECM TORQUE ECM <br /> BTU (a) 46500 46500 Dia.x Width(in.) 10.62 X 10.62 10.62 X 10.62 <br /> Indoor Airflow(CFM) 1600 1600 Drive/No.Speeds DIRECT/3 DIRECT/3 <br /> Power Input(KW) 4.09 4.09 CFM @ 0.0 in.w.g.(9) SEE FAN PERF TABLE SEE FAN PERF <br /> TABLE <br /> EER/SEER(BTU/Watt <br /> Hr.) 11.50/14.00 11.50/14.00 Motor—HP/R.P.M. 3/4/1050 3/4/1050 <br /> Sound Power Rating 72 5 72 5 Volts/Ph/Hz 208-230/1/60 208-230/1/60 <br /> [dB(A)](b) <br /> PERFORMANCE F.L.Amps 6 6 <br /> HEATING(c) COMBUSTION FAN <br /> Input BTUH-1st Stage 70000 90000 —TYPE CENTRIFUGAL CENTRIFUGAL <br /> (Natural Gas)(d) Drive/No.Speeds DIRECT/1 DIRECT/1 <br /> AFUE 81 81 Motor—HP/R.P.M. 1/34/3290 1/34/3075 <br /> Temp.Rise—Min/Max 30/60 35/65 Volts/Ph/Hz 230/1/60 230/1/60 <br /> Orifice Qty/Drill Sz. 2/#33 3/#37 FLA .20 .24 <br /> (Natural Gas) FILTER/ <br /> POWER CONN.—V/ 208-230/1/60 208-230/1/60 FURNISHED NO NO <br /> Ph/Hz <br /> Min.Brch.Cir. Type Recommended THROWAWAY THROWAWAY <br /> Ampacity(e) 32.0 32.0 Recmd.Face Area(sq. <br /> Fuse Size—Max. 50 50 ft)(h) 5.3 5.3 <br /> (amps) REFRIGERANT R-410 R-410 <br /> Fuse Size—Recmd. 50 50 <br /> (amps) Charge(lbs.) 7.5 7.5 <br /> COMPRESSOR SCROLL SCROLL CHARGING <br /> VOLTS/PH/HZ 208-230/1/60 208-230/1/60 SPECIFICATIONS <br /> Subcooling SO° 10° <br /> R.L.Amps—L.R. 19.6/130.0 19.6/130.0 <br /> AmpsGAS PIPE SIZE(in.) 1/2 1/2 <br /> OUTDOOR COIL— SPINE-FIN SPINE-FIN DIMENSIONS H X D X W H X D X W <br /> TYPE <br /> Rows/F.P.I 2/24 2/24 Crated(in.) 50 X 47 X 62 50 X 47 X 62 <br /> Face Area(sq.ft.) 20.54 20.54 WEIGHT <br /> Tube Size(in.) 3/8 3/8 Shipping(lbs.)/Net 552/448 557/453 <br /> (lbs.) <br /> INDOOR COIL— MCHE MCHE (a) Rated in accordance with AHRI Standard 210/240.AHRI standard <br /> TYPE rating conditions are:80 D.B.67 W.B.entering air to indoor coil.95 D. <br /> Rows/F.P.I 2/16 2/16 B.entering air to outdoor coil. <br /> Face Area(sq.ft.) 3.9 3.9 (b) Sound Power values are not adjusted for AHRI 270-95 tonal <br /> corrections. <br /> Tube Size Width(in.) .81 .81 (_) Ratings shown are for elevations up to 2000 ft.For higher elevations <br /> Refrigeration Control EXPANSION VALVE EXPANSION VALVE reduce ratings at a rate of 4%per 1000 ft.elevation. <br /> (d) Convertible to LPG. <br /> Drain Conn.Size(in.) 3/4 FEMALE NPT 3/4 FEMALE NPT (e) This value is approximate.For more precise value,see Unit <br /> OUTDOOR FAN— Nameplate. <br /> TYPE SWEPT SWEPT M Standard Air—Dry Coil—Outdoor. <br /> (9) Based on U.S.Government Standard Tests. <br /> DIA.(IN.) 28.25 28.25 (h) Filters must be installed in return airstream.Square footages listed <br /> DRIVE/NO.SPEEDS DIRECT/1 DIRECT/1 are based on 300 f.p.m.face velocity.If permanent filters are used <br /> CFM @ 0.0 in.w.g.(f) 4800 4800 size per manufacturer's recommendation with a clean resistance of <br /> 0.05"W.C. <br /> Motor—HP/R.P.M 1/4/825 1/4/825 <br /> Volts/Ph/Hz 208-230/1/60 208-230/1/60 <br /> 4YCC4048A-SUB-1 F-EN 3 <br />