I <br /> REGULATORY INFORMATION INTEGRATION OF DETECTORS <br /> I North American CAN/ULC-S529-09, UL 268, UL 268A, DS PS detectors can be mixed in any order with SmartOne <br /> standards FM Approvals 3230 legacy detectors on a Kidde Fire Systems intelligent control unit <br /> UL/cUL smoke 0.9 to 3.50%/ft. (2.95 to 11.48%/m) running SmartOne protocol. <br /> 1 sensitivity range obscuration (Open Area Use) COMPATIBLE CONTROL UNITS <br /> 0.9 to 2.0%/ft. (2.95 to 6.56%/m)obscuration <br /> (In-Duct Use) Kidde ARIES NET Link <br /> I NOTE: Detector sensitivity is selected at Kidde ARIES <br /> control unit or with remote configuration Kidde PEGAsys <br /> software. Fenwal FenwaINET 8000-ML <br /> Default is 2.0%/ft(Alarm), 1.5%/ft(PreAlarm) Fenwal FenwaINET 6000 <br /> FCC compliance This device complies with part 15 of the FCC Fenwal FenwaINET 2000 <br /> Rules. Operation is subject to the following Chemetron MICRO MLX <br /> two conditions: (1)This device may not cause <br /> I harmful interference,and (2)this device must Chemetron MICRO SLX <br /> accept any interference received, including * <br /> interference that may cause undesired DS Series detectors are compatible with FenwaINET 2000 <br /> operation. and PEGAsys control units running software version 82.4. <br /> Industry Canada This Class A digital apparatus complies with Note that FenwaINET 2000 and PEGAsys control units are <br /> compliance Canadian ICES-003. no longer UL Listed or FM Approved. DS Series detectors <br /> have not been compatibility-tested on legacy control units <br /> I <br /> older than FenwaINET 2000 and PEGAsys. <br /> I <br /> ITO SMARTONE DS-PS o DS-HFS <br /> CONTROL UNIT CPD-7052,PSD-7152 DETECTOR TO <br /> OR or THD-7252 DETECTOR NEXT <br /> ANOTHER DETECTOR <br /> I DETECTOR <br /> (Not Polarity <br /> Sensitive) CI \ ❑0 <br /> I <br /> Figure 1: Combining Legacy Detectors with DS Series Detectors <br /> I (Class B, Style 4 Wiring Style Shown) <br /> INOTES: SOFTWARE NOTE: <br /> 1. Detectors are not polarity sensitive.Terminals 3 and 7 The DS-PS detector does NOT support configurable alarm <br /> (SmartOne)or Terminals 2 and 4 (DS Series)can be settings below 0.9%/ft. If a DS-PS is configured with a thresh- <br /> I reversed. old below 0.9%/ft.for Alarm or 0.7%/ft.for Pre Alarm,the detec- <br /> tor SmartOne and DS Series detectors can be installed in any for will operate at the lowest allowable setting. If the control unit <br /> order. is running software version 1.2.11 (for Single Loop panel) or <br /> 3. SLC loop is not sensitive to the location of the control unit software version 2.1.2 (for Multi Loop panel) or later, the mes <br /> I (can be left or right end of loop). sage 'INVALID THRESHOLD" will be reported on the Keypad/ <br /> 4. Four wire loops will be wired as above, bringing loose end Display. However, if the control unit is running an older version <br /> of loop back to the control unit. of software, no message will be reported. <br /> 1 <br /> K_76-101 3 ' Kidde <br /> Effective:January 2017 Fire Systems <br /> I <br />