My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-30 2024-04-02
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-30
>
3003 W CASINO RD BLDG 40-30 2024-04-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/2/2024 10:27:46 AM
Creation date
4/2/2024 10:27:02 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-30
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I SmartOne® r Kidde <br /> Addressable Contact Input Device Fire Systems <br /> IEffective: May 2020 <br /> K-76-701 <br /> FEATURES <br /> • Monitors N.O. or N.C. Unpowered Contacts • Class B Initiating Device Circuit <br /> • Full Digital Communications • Maximum 100 Ohm Loop Resistance(both conductors) <br /> Remote LED Output • <br /> UL Listed, ULC Listed <br /> • Alarm Test from Control Unit Keypad FM Approved <br /> DESCRIPTION <br /> I <br /> The SmartOne® Addressable Contact Input Device (Al) is an ne•Ilanalllin _1_, <br /> MODEL N.WO RN lid F <br /> intelligent field device with its own microprocessor, memoryand MONITOR MODULE WIE CI <br /> electronics necessary to interface N.O. or N.C. unpowered - ®- _i <br /> ' contacts to Kidde® intelligent control units. All of the electronics Q _� <br /> are contained in a high-impact polymer case, creating a very i .:' 1: 'a,( <br /> small and durable device for installation.A silicone free version is f-- _! <br /> available for applications where silicone is not desired. <br /> ' Two types of Al's are available: an Al/NC for interfacing to nor- SPECIFICATIONS <br /> mally-closed devices and an Al/NO for interfacing to normally- IDC Wiring Style:Wired as NFPA 72 Class B <br /> open devices. The Al may be located up to 3,500 feet from the Input Voltage: 24 VDC nominal <br /> I monitored device with #18 AWG wiring. An end-of-line-resistor is Standby Current:580 pA Max <br /> required for supervision of the wiring to the device. Alarm Current: 580 pA Max <br /> FIELD PROGRAMMING Max. Circuit Resistance: 100 Ohm (50 Ohm to conductor) <br /> System address, owner location message and reporting type are Operating Environment:-31 to 151°F(-35 to 66°C)at 0 to 95% RH <br /> programmable via the compatible control unit configuration soft- LED Pulse Modes: <br /> ware program. The system address is a 3-digit number that Normal: 9 second interval <br /> uniquely identifies each device. The owner location message is a Trouble: LED is off <br /> ' 40-character, alpha numeric message that describes the location Alarm: 2 second interval <br /> of the device. The reporting type is assigned to the Al depending Acceptable Wire Size: 14, 16, 18 AWG <br /> on the functionality of the device being monitored. The Al can be mounted in a North American 2-1/2-in. (64 mm)deep, <br /> I <br /> SUPERVISION The Al continuously monitors the integrity of the following: 1-gang box or standard 4-in.square box, 1-1/2-in.(38 mm)deep with <br /> cover. <br /> COMPATIBLE CONTROL UNITS <br /> • Continuity of supervised wiring I <br /> Fire Alarm <br /> Power/Communications circuit voltage Current Legacy <br /> • <br /> • Internal power supply Control Unit Product Product <br /> • Memory data (FACU)Type <br /> • Faulty entering of data into Al memory Single Loop ARIES®-SLX ARIES <br /> STATUS LED FenwaINET'"6000 <br /> A remote status LED may be connected to the Al. MICRO SLX <br /> * <br /> PEGAsys'" <br /> I <br /> ALARM TEST FenwaINET 2000* <br /> Any or all Als can be tested by command from the compatible <br /> control unit. Results of the test may be printed. Multiple Loop ARIES®-MLX ARIES NETLink <br /> I <br /> ORDERING INFORMATION FenwaINET 8000-ML <br /> MICRO MLX <br /> Addressable Contact Input Device N.O 70-417008-001 PEGAs s* <br /> _ <br /> Addressable Contact Input Device N.O, 70-417018-001 FenwaINET 2000* <br /> I non-silicone <br /> * FACUs running software revision 82.4 are compatibility-tested but <br /> Addressable Contact Input Device N.C. 70-417008 002 not agency listed with the device(s)in this data sheet. <br /> Package of 10 End-of-Line Resistors 70-411001-005 EXPORT INFORMATION(USA)I <br /> Jurisdiction:EAR <br /> Kidde,SmartOne and ARIES are registered trademarks of Kidde-Fenwal,Inc.,or US ECCN:EAR99 <br /> its parents,subsidiaries or affiliates. This document contains technical data subject to the EAR. <br /> I <br /> This literature is provided for informational purposes only.KIDDE-FENWAL,INC.believes this data to be accurate,but it is pub- <br /> Kiddelished and presented without any guarantee or warranty whatsoever.KIDDE-FENWAL,INC.assumes no responsibility for the <br /> product's suitability for a particular application.The fire suppression system design,installation,maintenance,service and trouble- Fire• Systems <br /> lemS <br /> shooting must be performed by trained,authorized Kidde Fire Systems distributors for the product to work correctly.If you need <br /> more information on this product,or if you have a particular problem or question,contact: KIDDE-FENWAL,INC.,Ashland,MA 400 Main Street <br /> 01721 USA,Telephone:(508)881-2000. Ashland,MA 01721 USA <br /> I <br /> K-76-701 Rev AC ©2020 Kidde-Fenwal Inc. Tel:508.881.2000 <br /> www.kiddefiresystems.corn <br />
The URL can be used to link to this page
Your browser does not support the video tag.