M1`TI <br /> Hilti PROFIS Engineering 3.0.66 <br /> www.hilti.com <br /> Company: Page: 6 <br /> Address: Specifier: <br /> Phone I Fax: ! E-Mail: <br /> Design: Concrete-Oct 19,2020 Date: 1/15/2021 <br /> Fastening point: <br /> 6 Warnings <br /> • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations(AS 5216:2018,ETAG 001/Annex C, <br /> EOTA TR029 etc.).This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered-the <br /> anchor plate is assumed to be sufficiently stiff,in order not to be deformed when subjected to the design loading.PROFIS Engineering calculates <br /> the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above.The <br /> proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for <br /> agreement with the existing conditions and for plausibility! <br /> • Condition A applies where the potential concrete failure surfaces are crossed by supplementary reinforcement proportioned to tie the potential <br /> concrete failure prism into the structural member.Condition B applies where such supplementary reinforcement is not provided,or where pullout <br /> or pryout strength governs. <br /> • Refer to the manufacturer's product literature for cleaning and installation instructions. <br /> • For additional information about ACI 318 strength design provisions,please go to https://submittals.us.hi►ti.com/PROFISAnchorDesignGuide/ <br /> • Hilti post-installed anchors shall be installed in accordance with the Hilti Manufacturer's Printed Installation Instructions(MPII).Reference ACI <br /> 318-14,Section 17.8.1. <br /> Fastening meets the design criteria! <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2021 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 18/20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.