Laserfiche WebLink
Intelligent Input-Output <br /> (< I N O I r.> `, <br /> Univrsa <br /> Input! <br /> ,, '.L.,,, �,. SIGA-U106R <br /> _ P <br /> Output <br /> 3 ... ' , <br /> gg <br /> } x <br /> �%,Lk. R <br /> -.r -- • ---' ' 3 „,_44.‘: -1/4...---) <br /> M th rb ar ,,,,, <br /> SIGA—UIO2R, SIGA—UIO6R, . .cA. * .x <br /> 5 <br /> - 1'' (3 <br /> 4 04 7300 1657: <br /> 0121 <br /> SIGA-U102R 1-I f i <br /> LC <br /> S3424 <br /> Overview Standard Features <br /> Signature Series Universal Input-Output Module Motherboards • Modular flexibility <br /> provide mounting and wiring terminations for up to six Signature Wide assortment of multi-function plug-in modules provides <br /> Series plug-in UIO(SIGA-"M"series)modules. UIO motherboards total flexibility. <br /> slide into a rigid extruded track(included)with mounting pads • Minimum wiring requirements <br /> for convenient mounting into a variety of equipment enclosures. Integral jumpers between modules allow sharing of risers to <br /> UIO modules plug into the board and are held securely in place reduce installation wiring. <br /> with captive machine screws.All field wiring connects to terminal <br /> blocks on the motherboard,which permits rapid removal and • Easy installation <br /> replacement of modules for troubleshooting. #12 AWG(2.5 mm2)terminal blocks and sturdy mounting pads <br /> The SIGA-U102R provides mounting and wiring terminations for ensure quick installation into EDWARDS enclosures. <br /> up to two UIO modules, and the SIGA-U106R provides mounting • Supports automatic device mapping <br /> and wiring terminations for up to six UIO modules. Both mother- All compatible UIO modules transmit information to the loop <br /> boards feature a riser#1 input and a riser#2 input bus.Jumpers controller regarding their circuit locations with respect to other <br /> on riser#1 input, between modules,facilitate sharing a single riser Signature devices on the wire loop. <br /> among more than one module.This significantly reduces wiring • Supports intelligent devices <br /> requirements. Removing the jumpers provide separate riser inputs <br /> to each adjacent module. Riser#2 input is fixed to each module On-board modules make decisions and input an alarm from <br /> position and cannot be split. initiating devices connected to them even if the loop controller's <br /> polling interrogation stops. <br /> The SIGA-U106 provides mounting and wiring terminations for up <br /> to six UIO modules.This motherboard provides two riser inputs • Twisted or shielded wire not required <br /> that are common to all modules. Because all decisions are made at the on-board modules, <br /> lower communication speeds are possible.This results in <br /> substantially improved control panel response time and less <br /> sensitivity to line noise and loop wiring properties. <br /> • Supports electronic addressing <br /> Programmable addresses are downloaded to compatible UIO <br /> modules from the loop controller,a PC, or the SIGA-PRO <br /> Signature Program/Service Tool.There are no switches or dials <br /> to set. <br /> Page 1 of 4 E8500 03655 <br /> Issue 1.1 <br />