Typical Wiring Graphic Annunciator Field Wiring <br /> Rear view 3-ANNCPU3 Field Wiring AR <br /> RS.485 NETWORK DATA RS-485 NETWORK DATA <br /> 3-6ANN Shown FROM PREVIOUS PANEL TO NEXT PANEL <br /> Ground Lead 24VDC FROM 3-PPS/NI OR 3-BPS/M 24VDC TO NEXT <br /> To Backbox POWER RISER , Q • ^� POWER MODULE <br /> Z ¢ m <br /> 0 Y Y <br /> O <br /> CC <br /> 0 0 0 <br /> O O <br /> = w Power limited <br /> ¢ N V. ¢a z z circuit Graphic Annunciator <br /> w +- +-co +-+— <br /> ® IHIII <br /> 1 k ! 4 6 > e e 10 <br /> \O00000000pz <br /> TToTBI on 3-ANNCPU3 \---------- .. <br /> NOTES: <br /> i <br /> 1.All wiring except earth Wire Specifications <br /> If ® I Ej <br /> ground supervised and power Network Data Communications RS4.85 Format <br /> 13 <br /> limited. <br /> 3 ° 2.24 VDC available from Minimum Twisted Pair 18 AWG(0.75 mm2). <br /> I I Primary or Booster Power Maximum Circuit Resistance 90 Ohms <br /> supply. Maximum Circuit Capacitance 0.3 pF <br /> fl <br /> 1� 3.Uses RS-485 Network Maximum Distance <br /> . communication format between any 3 panels 5,000 ft.(1,524 m). <br /> 4.Network wiring Twisted Pair <br /> Capacitance,entire network <br /> Maximum Accumulative Capacitance <br /> Power Riser <br /> Calculate wire size for a maximum 3.4 Vdc total line loss from the 24 Vdc Wire Size 38.4K Baud 19,2K Baud <br /> nominal voltage. 18 AWG 1.4 pF 2.8 pF <br /> 16AWG 1.8pF 3.6pF <br /> 14 AWG 2.1 pF 4.2 OF <br /> Distance limits are determined using the maximum allowable circuit <br /> resistance and capacitance,and manufacturer's cable specifications. <br /> Specifications <br /> Catalog Number 3-ANNCPU3 I 3-ANFtSM 3-LCD 3-LCDXL1 <br /> Agency Listings 1 UL,ULC,FM,CE,LPCB EN54° UL, ULC,FM <br /> Mounting Space Two Spaces One Space Mounts over 3-ANNCPU Mounts over 3-ANNCPU <br /> plus two spaces. <br /> Communication Format RS-485 N/A N/A N/A <br /> Current @ 24 Vdc <br /> Standby 144 mA 10mA 40mA 48mA <br /> Alarm 144 mA 10mA 42mA 50mA <br /> Wiring Termination Plug in terminal strip <br /> Wiring Size Twisted Pair 18-14 AWG <br /> (0.75-1.5 mm2) N/A <br /> Max.Wire Distance 5000 ft(1524m) <br /> between any 3 panels <br /> Relative Humidity 93%non condensing at 90°F(32°C) <br /> Temperature Rating 0-49°C(32-120°F) <br /> Wiring Styles Class A or Class B <br /> Note:For a complete list of EST3 annunciator display and control modules please refer to EDWARDS literature sheet part number <br /> 85010-0055. <br /> 'EN54-16:(2008),EN54-2:1997+A1 and EN54-4:1997+A1:2002+A2 <br /> Engineering Specification <br /> The Life Safety system shall incorporate annunciation of Alarm, units.The LCD interface must provide the ability to display custom <br /> Supervisory,Trouble and Monitor operations.Annunciation must event messages of a minimum of 40 characters.The LCD must <br /> be through the use of both LED display strips complete with a provide the emergency user, hands free viewing of the first and <br /> means to custom label each LED as to its function.Where ap- last highest priority event.The last highest priority event must <br /> plicable control switches must be provided. Switches with LEDs always display and update automatically. System events must <br /> must provide positive feed back to the operator of remote equip- automatically be placed in queues. It shall be possible to view <br /> ment status.An LCD display with basic common control LEDs specific event types separately. Having to scroll through a mixed <br /> and switches shall be provided.The Common Control Switches list of events types is not acceptable.The total number of active <br /> and LEDs provided as minimum will be: Reset switch and LED, events by type must be displayed. It must be possible to custom- <br /> Alarm Silence switch and LED, Panel Silence switch and LED, Drill ize the designations of all user interface LEDs and switches for <br /> switch and LED. It must be possible to add additional common local language requirements. It must be possible to route system <br /> controls as required though the use of modular display/control event messages to specific annunciator locations. <br /> p� <br /> Page 2 of 4 E850 q 1 0-0069 <br /> Issue 1.1 <br />