My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application Dimensions <br /> The BPS provides additional power and circuits for notification ap- <br /> pliances and other 24 Vdc loads. It is listed for indoor dry locations <br /> and can easily be installed where needed. y 0 O O <br /> Top View <br /> Fault conditions are indicated on the on-board diagnostic LEDs, <br /> opening the BPS input sense circuit and the trouble relay(if 14-D2 Ii D3 ►1 <br /> programmed).While this provides indication to the host system, <br /> the BPS can still be activated upon command.A separate AC �� lirFail contact is available on the BPS circuit board, which can be 04—D4�0 <br /> programmed for trouble or AC Fail.There are seven on-board <br /> .diagnostic LEDs: one for each NAC fault, one for battery fault, one a) Front View Ofor ground fault, and one for AC power. a> —The unique dual-input activation circuits of the BPS can be acti- <br /> vated by any voltage from 6 to 45 VDC(filtered-regulated)or 11 D1 0 D6 <br /> to 33 Vdc(full-wave rectified, unfiltered).The first input circuit canObe configured to activate 1-4 of the four possible outputs.The to <br /> second input circuit can be configured to control circuits 3 and 4. All knockouts mWhen outputs are configured for auxiliary operation,these circuits for 3/4 in conduitcan be configured to stay on or automatically deactivate 30 sec- ° (1.9 cm) o 5onds after AC power is lost.This feature makes these circuits ideal ofor door holder applications.The BPS also has a separate 200 <br /> mA 24 Vdc output that can be used to power internal activation �■ 1 111111111161 <br /> modules. <br /> BPS NACs can be configured for a 3-3-3 temporal or continuous D1 D2 D3 D4 D5 D6 <br /> output.This makes the BPS ideal for applications requiring signal- 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in <br /> ing rates that are not available from the main system. (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) <br /> In addition to the internally generated signal rates,the BPS can <br /> also be configured to follow the coded signal rate of the main <br /> system NACs.This allows for the seamless expansion of existing Wire routing Power-limited <br /> NACs. <br /> wiring area <br /> The BPS enclosure has mounting brackets for up to three Signa- <br /> ture modules to the right of the circuit board. ' ■I <br /> ■ <br /> o O° <br /> Engineeri I ng Specification litc" ■ <br /> Supply,where needed, EDWARDS BPS Series Booster Power <br /> Supplies(BPS)that are interconnected to and supervised by the ``-, <br /> main system.The BPS shall function as a stand-alone auxiliary I El � I_, <br /> power supply with its own fully-supervised battery compliment. ❑ i ■ <br /> The BPS battery compliment shall be sized to match the require- . •o all 1 4[3] •� <br /> ments of the main system.The BPS shall be capable of supervis- Route AC supply - i!, ��^li <br /> ing and charging batteries having the capacity of 24 ampere-hours through these .._— ='' °o° <br /> for Mass Notification/Emergency Communication (MNEC), life knockouts only • —■ <br /> safety applications. (Nonpower-limited '.' ALM' <br /> and supervised) Battery wiring (nonpower- <br /> «The BPS shall be capable of installation for a seismic corn- limited and supervised) o <br /> ponent Importance Factor of 1.5.»The BPS shall provide a <br /> minimum of four independent,fully supervised Class B circuits Battery Battery <br /> that can be field configurable for notification appliance circuits or <br /> auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to _ <br /> a minimum of two Class A NACs. Each BPS output circuit shall be <br /> rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- <br /> vided with automatically restoring overcurrent protection.The BPS Notes <br /> shall be operable from the main system NAC and/or EDWARDS 1. Maintain 1/4-inch(6 mm)spacing between power-limited and nonpower-limited <br /> Signature Series control modules. BPS NACs shall be configurable Firing or use type FPL,FPLR,or FPLP cable per NEC. <br /> [2] Power-limited and supervised when not configured as auxiliary power.Non- <br /> for continuous or 3-3-3 temporal rate. Fault conditions on the BPS supervised when configured as auxiliary power. <br /> shall not impede operation of main system NAC.The BPS shall be [3] Source must be power-limited.Source determines supervision. <br /> provided with ground fault detection circuitry and a separate AC 4. When using larger batteries,make sure to position the battery terminals towards <br /> fail relay. the door. <br /> Page 2 of 4 E85005-0I 25 <br /> Issue 1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.