My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application Installation <br /> The SIGA-CC1S mounts to a standard North American two-gang The SIGA-CC1S:mounts to North American 2-1/2 inch (64 mm) <br /> electrical box, making it ideal for locations where only one module deep 2-gang boxes and 1-1/2 inch(38 mm)deep 4 inch square <br /> is required. Separate I/O and data loop connections are made to boxes with 2-gang covers and SIGA-MP mounting plates.The <br /> each module. terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2) <br /> The SIGA-MCC1S is part of the UIO family of plug-in Signature wire size. <br /> Series modules. It functions identically to the SIGA-CC1 S, but <br /> takes advantage of the modular flexibility and easy installation that O <br /> characterize all U1O modules.Two-and six-module UIO mother- r • <br /> boards are available.These can accommodate individual risers for ` <br /> each on-board module, or risers that are shared by any combina- Q <br /> tion of its UIO modules.All wiring connections are made to termi- Q' • ,` <br /> nal blocks on the motherboard. UIO assemblies may be mounted160.6 <br /> in EDWARDS enclosures. A \:� • eV" <br /> Personality Codes ®0 <br /> The operation of the SIGA-CC1 S is determined by their sub-type <br /> code or"Personality Code".The code is selected by the installer SIGA-MCC1S:mount the UlOxR motherboard inside a suitable <br /> depending upon the desired application and is downloaded from EDWARDS enclosure with screws and washers provided. Plug the <br /> the loop controller. module into any available position on the motherboard and secure <br /> Personality Code 5:Signal Power or Audio Evacuation(sin- the module to the motherboard with the captive screws.Wiring <br /> gie riser).Configures the module for use as a Class B Audible/ connections are made to the terminals on the motherboard(see <br /> Visible Signal power(24 Vdc polarized)or Audio Evacuation (25 wiring diagram). UlOxR motherboard terminals are suited for#12 <br /> or 70 VRMS) power selector.The ring-tone generator is disabled. to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. <br /> The output circuit is monitored for open or shorted wiring. If a <br /> short exists,the control panel inhibits the activation of the audible/ <br /> visible signal circuit to prevent connection to the power circuit. UIO Motherboard <br /> Personality Code 6:Telephone with ring-tone(single riser). - —� <br /> Configures the module for use as a Telephone power selector. --I - 1--40 <br /> When a telephone handset is plugged into its jack or lifted from its Plug-in(UIo) <br /> hook,the module generates its own Ring-Tone signal.A separate Module <br /> ring-tone circuit is not needed.The module sends this signal to -- b-11--44 <br /> the control panel to indicate that an off-hook condition is present. <br /> When the system operator responds to the call,the ring-tone <br /> signal is disabled. <br /> •— Cabinet or electrical enclosure <br /> Personality Code 25:Visual Signal Synchronization.This <br /> personality code configures the module to provide synchronization <br /> of fire alarm signals across multiple zones. It functions as a signal <br /> power(24 Vdc)riser selector.The output wiring is monitored for Electronic Addressing <br /> open circuits and short circuits.A short circuit will cause the fire The loop controller electronically addresses each module saving <br /> alarm control panel to inhibit the activation of the audible/visual valuable time during system commissioning. Setting complicated <br /> signal circuit so the riser is not connected to the wiring fault. switches or dials is not required. Each module has its own unique <br /> serial number stored in its"on-board memory".The loop control- <br /> ler identifies each device on the loop and assigns a"soft"address <br /> Warnings & Cautions to each serial number. If desired,the modules can be addressed <br /> This module will not operate without electrical power.As fires fre using the SIGA-PRO Signature Program/Service Tool. <br /> quently cause power interruption,we suggest you discuss further <br /> safeguards with your fire protection specialist. Testing & Maintenance <br /> EDWARDS recommends that these modules be installed accord- The module's automatic self-diagnosis identifies when it is defec- <br /> ing to latest recognized edition of national and local fire alarm tive and causes a trouble message.The user-friendly maintenance <br /> codes. program shows the current state of each module and other perti- <br /> nent messages. Single modules may be turned off(de-activated) <br /> temporarily,from the control panel. <br /> Compatibility Scheduled maintenance(Regular or Selected)for proper system <br /> These modules are part of EDWARDS's Signature Series intelligent operation should be planned to meet the requirements of the <br /> processing and control platform.They are compatible with EST3, Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and <br /> EST3X and 10 Series control panels. ULC CAN/ULC 536 standards. <br /> Page 2 of 4 E8500#-V 543 <br /> Issue 1.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.