Application Installation <br /> The SIGA-CC1S mounts to a standard North American two-gang The SIGA-CC1S:mounts to North American 2-1/2 inch (64 mm) <br /> electrical box, making it ideal for locations where only one module deep 2-gang boxes and 1-1/2 inch(38 mm)deep 4 inch square <br /> is required. Separate I/O and data loop connections are made to boxes with 2-gang covers and SIGA-MP mounting plates.The <br /> each module. terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2) <br /> The SIGA-MCC1S is part of the UIO family of plug-in Signature wire size. <br /> Series modules. It functions identically to the SIGA-CC1 S, but <br /> takes advantage of the modular flexibility and easy installation that O <br /> characterize all U1O modules.Two-and six-module UIO mother- r • <br /> boards are available.These can accommodate individual risers for ` <br /> each on-board module, or risers that are shared by any combina- Q <br /> tion of its UIO modules.All wiring connections are made to termi- Q' • ,` <br /> nal blocks on the motherboard. UIO assemblies may be mounted160.6 <br /> in EDWARDS enclosures. A \:� • eV" <br /> Personality Codes ®0 <br /> The operation of the SIGA-CC1 S is determined by their sub-type <br /> code or"Personality Code".The code is selected by the installer SIGA-MCC1S:mount the UlOxR motherboard inside a suitable <br /> depending upon the desired application and is downloaded from EDWARDS enclosure with screws and washers provided. Plug the <br /> the loop controller. module into any available position on the motherboard and secure <br /> Personality Code 5:Signal Power or Audio Evacuation(sin- the module to the motherboard with the captive screws.Wiring <br /> gie riser).Configures the module for use as a Class B Audible/ connections are made to the terminals on the motherboard(see <br /> Visible Signal power(24 Vdc polarized)or Audio Evacuation (25 wiring diagram). UlOxR motherboard terminals are suited for#12 <br /> or 70 VRMS) power selector.The ring-tone generator is disabled. to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. <br /> The output circuit is monitored for open or shorted wiring. If a <br /> short exists,the control panel inhibits the activation of the audible/ <br /> visible signal circuit to prevent connection to the power circuit. UIO Motherboard <br /> Personality Code 6:Telephone with ring-tone(single riser). - —� <br /> Configures the module for use as a Telephone power selector. --I - 1--40 <br /> When a telephone handset is plugged into its jack or lifted from its Plug-in(UIo) <br /> hook,the module generates its own Ring-Tone signal.A separate Module <br /> ring-tone circuit is not needed.The module sends this signal to -- b-11--44 <br /> the control panel to indicate that an off-hook condition is present. <br /> When the system operator responds to the call,the ring-tone <br /> signal is disabled. <br /> •— Cabinet or electrical enclosure <br /> Personality Code 25:Visual Signal Synchronization.This <br /> personality code configures the module to provide synchronization <br /> of fire alarm signals across multiple zones. It functions as a signal <br /> power(24 Vdc)riser selector.The output wiring is monitored for Electronic Addressing <br /> open circuits and short circuits.A short circuit will cause the fire The loop controller electronically addresses each module saving <br /> alarm control panel to inhibit the activation of the audible/visual valuable time during system commissioning. Setting complicated <br /> signal circuit so the riser is not connected to the wiring fault. switches or dials is not required. Each module has its own unique <br /> serial number stored in its"on-board memory".The loop control- <br /> ler identifies each device on the loop and assigns a"soft"address <br /> Warnings & Cautions to each serial number. If desired,the modules can be addressed <br /> This module will not operate without electrical power.As fires fre using the SIGA-PRO Signature Program/Service Tool. <br /> quently cause power interruption,we suggest you discuss further <br /> safeguards with your fire protection specialist. Testing & Maintenance <br /> EDWARDS recommends that these modules be installed accord- The module's automatic self-diagnosis identifies when it is defec- <br /> ing to latest recognized edition of national and local fire alarm tive and causes a trouble message.The user-friendly maintenance <br /> codes. program shows the current state of each module and other perti- <br /> nent messages. Single modules may be turned off(de-activated) <br /> temporarily,from the control panel. <br /> Compatibility Scheduled maintenance(Regular or Selected)for proper system <br /> These modules are part of EDWARDS's Signature Series intelligent operation should be planned to meet the requirements of the <br /> processing and control platform.They are compatible with EST3, Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and <br /> EST3X and 10 Series control panels. ULC CAN/ULC 536 standards. <br /> Page 2 of 4 E8500#-V 543 <br /> Issue 1.2 <br />