My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
;.1 y Cates cg 0. Intelligent Input-Output <br /> LIFE SAFETY (it INCIDENT MANAGEMENT <br /> Isolt Module o <br /> SIGA-IM2 <br /> 53424 <br /> 7300-1657: <br /> 012141>Overview Automatic Device Mapping-The Signature loop controller <br /> The SIGA-IM2 Isolator Module is part of EDWARDS's Signature learns keeps a map where each device's serial number address <br /> is installed relative to other devices on the data circuit. <br /> Series system.This intelligent device enables part of the Signature <br /> data loop to continue operating should a short circuit occur.The Fast Stable Communication-Built-in intelligence means less <br /> module can be wired into a Class A data loop at any point. information needs to be sent between the module and the loop <br /> controller.Other than regular supervisory polling response,the <br /> If a fault occurs,the isolator cuts power to all devices beyond the module only needs to communicate with the loop controller <br /> isolator on the loop as follows: when it has something new to report. <br /> • a short on the line causes all isolators to open within 23 msec. <br /> • at 10 msec intervals, beginning on one side of the Class A Standard Features <br /> circuit nearest the loop controller,the isolators close to provide <br /> the next isolator down the line with power. • Automatic device mapping <br /> • when the isolator next to the short closes,it reopens within Each module transmits wiring information to the loop <br /> 10 msec. controller regarding its location with respect to other devices <br /> on the circuit. <br /> Once activated,the line fault isolator continuously checks the <br /> • <br /> faulted side of the loop to determine if the short still exists.When Electronic addressing <br /> the fault is corrected and system reset,the module automatically Addresses are downloaded and permanently stored from <br /> restores the entire data loop to the normal condition. a PC,or the SIGA HDT Signature Program/Service Tool. <br /> There are no switches or dials to set. <br /> The microprocessor in every Signature module provides at least • Ground fault detection by address <br /> three important benefits— Self-diagnostics and History Log, Detects ground faults right down to the device level. <br /> Automatic Device Mapping,and Fast, Stable Communication. <br /> Self-diagnostics and History Log-Each Signature Series <br /> • 2-gang mounting <br /> module constantly runs self-checks to provide important <br /> maintenance information. This information is automatically <br /> updated and permanently stored in the module's non-volatile <br /> memory and is accessible for review any time using the SIGA-HDT <br /> Signature Program/Service Tool. <br /> Page 1 of 4 E85001-0272 <br /> Issue 1.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.