Laserfiche WebLink
;.1 y Cates cg 0. Intelligent Input-Output <br /> LIFE SAFETY (it INCIDENT MANAGEMENT <br /> Isolt Module o <br /> SIGA-IM2 <br /> 53424 <br /> 7300-1657: <br /> 012141>Overview Automatic Device Mapping-The Signature loop controller <br /> The SIGA-IM2 Isolator Module is part of EDWARDS's Signature learns keeps a map where each device's serial number address <br /> is installed relative to other devices on the data circuit. <br /> Series system.This intelligent device enables part of the Signature <br /> data loop to continue operating should a short circuit occur.The Fast Stable Communication-Built-in intelligence means less <br /> module can be wired into a Class A data loop at any point. information needs to be sent between the module and the loop <br /> controller.Other than regular supervisory polling response,the <br /> If a fault occurs,the isolator cuts power to all devices beyond the module only needs to communicate with the loop controller <br /> isolator on the loop as follows: when it has something new to report. <br /> • a short on the line causes all isolators to open within 23 msec. <br /> • at 10 msec intervals, beginning on one side of the Class A Standard Features <br /> circuit nearest the loop controller,the isolators close to provide <br /> the next isolator down the line with power. • Automatic device mapping <br /> • when the isolator next to the short closes,it reopens within Each module transmits wiring information to the loop <br /> 10 msec. controller regarding its location with respect to other devices <br /> on the circuit. <br /> Once activated,the line fault isolator continuously checks the <br /> • <br /> faulted side of the loop to determine if the short still exists.When Electronic addressing <br /> the fault is corrected and system reset,the module automatically Addresses are downloaded and permanently stored from <br /> restores the entire data loop to the normal condition. a PC,or the SIGA HDT Signature Program/Service Tool. <br /> There are no switches or dials to set. <br /> The microprocessor in every Signature module provides at least • Ground fault detection by address <br /> three important benefits— Self-diagnostics and History Log, Detects ground faults right down to the device level. <br /> Automatic Device Mapping,and Fast, Stable Communication. <br /> Self-diagnostics and History Log-Each Signature Series <br /> • 2-gang mounting <br /> module constantly runs self-checks to provide important <br /> maintenance information. This information is automatically <br /> updated and permanently stored in the module's non-volatile <br /> memory and is accessible for review any time using the SIGA-HDT <br /> Signature Program/Service Tool. <br /> Page 1 of 4 E85001-0272 <br /> Issue 1.0 <br />