My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application The sampling tube may be installed from either the duct side of <br /> SuperDuct detectors are ideally suited to duct smoke detection the assembly or from inside the sensor compartment,as preferred <br /> by the installer.(The exhaust tube must be installed from the duct <br /> applications whereearly indication of combustion is required within <br /> the confined space of ventilation ductwork. Its primarypurpose side.)Sampling tubes may be rotated in 45-degree increments so <br /> is to provide early warning of an impending fire and to prevent thalholes be aligned to allow the unit to be mounted at <br /> virtuallyt any angle relative to the air flow. <br /> smoke from circulating throughout the building. It is typically used <br /> to detect smoke in the supply side of the HVAC system but can In installations where the duct smoke detector's controls and indica- <br /> provide supervision of the return side as well. tors are hidden-from-view;a remote test station or an LED indicator <br /> can be connected to the detector to provide-these-functions.- <br /> Protected premises —_--__--Remote Remote Test Stations <br /> Alarm output relay t <br /> station . i Labor-saving Remote Test/Reset stations provide <br /> 1 alarm testing from the convenience of a remote <br /> - oca ion. es s can rimed-guiek+y-and safely <br /> Duct smoke C i Return ' - — •without havingto climb to the roof. Magnetically- <br /> _ <br /> detector air 9 Y- <br /> i HVAC <br /> I, I, operated and key-operated one-gang models are <br /> unit _ available.Signature SuperDuct detectors are also <br /> Duct smoke 1 >supply -" compatible with SIGA-LED remote alarm LED. <br /> — detector air <br /> T Air velocity in the duct as low as 100 ft/min. maintains adequate <br /> warm rela air flow into the sensor smoke chamber through air holes in the air <br /> output y Remote <br /> sampling tube and discharges through the exhaust tube.Su- <br /> FACP stest <br /> tation perDuct air sampling tubes must be installed with the inlet holes <br /> facing the airstream.Sampling tubes may be rotated in 45-degree <br /> increments so that air-holes can be aligned to allow the unit to be <br /> SuperDuct detectors continually sample air flow in the HVAC duct mounted in virtually any angle relative to the airflow. <br /> and initiate an alarm condition whenever smoke is detected. An SuperDuct sensors are engineered to operate optimally under the <br /> alarm is activated when the quantity(percent obscuration)of harsh environmental conditions frequently found in HVAC duc- <br /> combustion products in that air sample exceeds the detector's twork. Nonetheless,before installing the detector,test the duct <br /> sensitivity setting. air velocity,temperature,and humidity to verify that it is within the <br /> operating range of the SuperDuct detector.Consult the SuperDuct <br /> Signature Series Intelligence installation sheet for details. <br /> Like all Signature detectors,the SIGA-SD features electronic <br /> addressing and issues a dirty sensor warning when it reaches its Dimensions <br /> preset limit.The dirty sensor warning indicates the sensor is op- <br /> erating within its specified limits but is in need of servicing.When 8.70in(22.1 cm) <br /> the detector's ability to compensate for environmental changes »5 n(9.7cm <br /> has reached its limit,the duct smoke detector signals a trouble 3.08in(7.82 an) 1.601n <br /> condition. `4.06 cm) <br /> — <br /> The SIGA-SD also uses differential sensing to prevent gradual ,, , , <br /> environmental changes from triggering unwanted alarms.A rapid <br /> change in environmental conditions,such as smoke from a fire, <br /> causes the detector to signal an alarm state,but dust and debris7 0 0 <br /> accumulated over time does not change alarm sensitivity. I I _ 1 i <br /> Each Signature Series SuperDuct detector contains a-microproc- -----cr - } <br /> essor that performs comprehensive self-diagnostics and stores <br /> the results in nonvolatile memory.Stored results include details 2.28 in <br /> such as hours of operation, last maintenance date,and number (5'e"") <br /> of alarms and troubles.This information can be retrieved and <br /> reviewed when desired. c.__ < <br /> Detector Configuration ?c 5,45 In <br /> The detector assembly cover provides easy access to the smoke (13.84 on) <br /> sensor,its wiring connections,sample and exhaust tubes,and the iMIME <br /> smoke chamber itself. o 0 0 0 <br /> 414 <br /> Air enters the detector's sensing chamber through a sampling .. _ <br /> tube(ordered separately)that extends into the duct and is directed I <br /> back into the ventilation system through an exhaust tube(in- i 1.90 In <br /> cluded).The difference in air pressure between the two tubes pulls ; c4.83 cm) <br /> 17 <br /> the sampled air through the sensing chamber.When a sufficient 1 '- Y ��` <br /> Y I <br /> amount of smoke is detected in the sensing chamber,the detector <br /> initiates an alarm. e P <br /> � ; <br /> 1.38In 5.40 In <br /> - - (3.51 on) (13.72 cm) <br /> Page 2 of 4 DATA SHEET E85001-0584 <br /> of =oE€€se :`or iris all Lion purr sw... Issue 1.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.