My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application Testing & Maintenance <br /> The SIGA-OSD detects particles from a wide range of combustion Each detector automatically identifies when it is dirty or defective <br /> sources and will trigger an alarm when smoke density in the and causes a"dirty detector"message.The detector's sensitivity <br /> chamber reaches preprogrammed level.Thanks to its high- measurement can also be transmitted to the loop controller. <br /> performance reflective response technology,the smoke sensor A sensitivity report may be printed to satisfy NFPA sensitivity <br /> responds quickly and reliably to a wide range of fire types, measurements,which must be conducted at the end of the first <br /> including both fast and slow burning fires fueled by combustibles year and every two years thereafter. <br /> typically found in modern multi-use buildings. The user-friendly maintenance program shows the current state <br /> of each detector and other pertinent messages. Single detectors <br /> Compatibility may be turned off temporarily from the control panel.Availability of <br /> maintenance features is dependent on the fire alarm system used. <br /> The SIGA-OSD detector is compatible only with control panels <br /> using a Signature Loop controller. - <br /> Accessories <br /> Installation Detector mounting bases have wiring terminals that are <br /> accessible from the"room-side"after mounting the base to the <br /> Signature Series detectors mount electrical box.The bases mount to North American 1-gang boxes <br /> to North American 1-gang boxes and to 31/2 inch or 4 inch octagon boxes, 11h inches(38 mm) <br /> 3-1/2 inch or 4 inch octagon _ =' deep.They also mount to European BESA and 1-gang boxes with <br /> boxes,and to 4 inch square sesr-loca"9 tab 60.3 mm fixing centers.The SIGA-SB4, SIGA-RB4, and SIGA-IB4 <br /> electrical boxes 1-1/2 inches mount to North American 4 inch sq. electrical boxes in addition to <br /> (38 mm)deep.They mount to ' the above boxes.They include the SIGA-TS4 Trim Skirt,which is <br /> European BESA and 1-gang r used to cover the"mounting ears"on the base.The SIGA-AB4G <br /> boxes with 60.3 mm fixing5 ' <br /> .n Indicator mounts to a 4 inch square box only. <br /> centers. See mounting base "' , <br /> installation and wiring for r— - <br /> more information. <br /> Sensing and reporting technology SIGA-AB4GR'/LF SIGA-SB SIGA-IB SIGa-RB SIGA-LED <br /> The microprocessor in each detector provides additional Audible Base Standard Base Isolator Base Relay Base Remote LED <br /> benefits-Self-diagnostics and History Log,Automatic Device Remote LED SIGA-LED-The remote LED connects to the <br /> Mapping, and Fast, Stable Communication. SIGA-SB or SIGA-SB4 Standard Base only. It features a North <br /> Self-diagnostics and History Log Each Signature Series American size 1-gang plastic faceplate with a white finish and <br /> detector constantly runs self-checks to provide important red alarm LED. <br /> maintenance information.The results of the self-check are SIGA-TS4 Trim Skirt-Supplied with 4 inch bases, it can also <br /> automatically updated and permanently stored in the detector's be ordered separately to use with the other bases to help hide <br /> non-volatile memory surface imperfections not covered by the smaller bases. <br /> Automatic Device Mapping -The loop controller learns where Sounder Bases-Signature Series sounder bases are designed <br /> each device's serial number address is installed relative to other for use where localized or group alarm signaling is required. <br /> devices on the circuit.The mapping feature provides supervision <br /> of each device's installed location to prevent a detector from being • SIGA-AB4G bases provide sounder capability to Signature <br /> reinstalled(after cleaning, etc.)in a different location from where it Series to heat and smoke detectors.They are not intended <br /> was originally. for use with combination carbon monoxide detectors in <br /> Fire-plus-CO mode. <br /> Fast Stable Communication-On-board intelligence means . SIGA-AB4GT bases provide sounder capability to Signature <br /> less information needs to be sent between the detector and the Series smoke and heat detectors, as well as carbon <br /> loop controller. Other than regular supervisory polling response, monoxide detectors when used with a SIGA-TCDR Temporal <br /> the detector only needs to communicate with the loop controller Pattern Generator. <br /> when it has something new to report. <br /> • SIGA-AB4G-LF bases provide 520 Hz low frequency <br /> sounder capability to Signature Series smoke and heat <br /> detectors, as well as carbon monoxide detectors when <br /> used with a SIGA-TCDR Temporal Pattern Generator.The <br /> SIGA-AB4G-LF is suitable for applications requiring low <br /> frequency audible tones. <br /> Page 2 of 4 E85001-1 OO1 <br /> Issue 1.4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.