My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Typical Wiring <br /> The detector mounting bases accept#18 AWG(0.75mm2),#16 Relay Detector Base,SIGA-RB,SIGA-RB4 <br /> (1.0mm2), #14 AWG(1.5mm2),and#12 AWG(2.5mm2)wire sizes. This base includes a relay. Nor- C "" coed "art °" Open <br /> Sizes#16 AWG(1.omm2)-and#1-8 AWG-(0.75mm2)are preferred mally Open or Normally Closed -- - <br /> for ease of installation. operation is selected during in- <br /> stallation.The dry contact is rated / `1 <br /> for 1 amplot duty)@ 30 Vdc. 0, �� <br /> Standard Detector Base,SIGA-SB,SIGA-SB4 <br /> f�ii <br /> The relay's position is supervised 02 <br /> This is the basic mounting base Remote LED to avoid accidentally jarring it out « • u � <br /> .... ��. DATA OUT(.) <br /> for EDWARDS Signature Series MaXresstance of position.The SIGA-RB can be DATA INT-) • �� i <br /> detectors.The SIGA-LED Re- it lI' per wire operated as a control relay if pro- <br /> must not exceed DATA OUT(+) <br /> mote LED is supported by this + 10 Ohms grammed to do so at the control DATA <br /> IN(-)in,econtroter To Next Device <br /> Base. / c' panel.The relay base does not or Previous Device <br /> Ter Description I \, _ support-the-SIGA-LED-Remote Tem1 Description1 Not Used a Di 1 Normaly Open <br /> 2 DATA IN/OUT(+) '� LED. CONTACT RATING 2 DATA IN/OUT(+) <br /> 3 Not Used •c, - 1.0 Amp @ 30 VDC 3 Common <br /> 4 DATA IN(-) \A (Pilot Duty) 4 DATA IN(-) <br /> 4 Remote LED(-) DATA IN 1-) z I / DATA OUT(-I - 5 Not Used 5 Remote LED(+) 6 Normally-Closed <br /> 6 Not Used 7 DATA OUT(-) <br /> 7 DATA OUT(. DATA IN I+) DATA OUT(+) <br /> From Signature Controller To Next Device <br /> or Previous Device <br /> Audible Sounder Bases,Fire Mode <br /> Isolator Detector Base,SIGA-IB,SIGA-184 AB4GT,AB4G,AB4G-LF sounder bases <br /> This base includes a built-in line fault isolator for use on Class A <br /> circuits.A detector must be installed for it to operate.The isolator (-- <br /> base does not support the SIGA-LED Remote LED. sIGA_v►eaGr o o SIGA-AB4G-LF: <br /> The isolator operates as follows: slGa-AB4G, ®Jum r cuts® Output Mode <br /> SIGA-AB4G-LF: Default=Fire <br /> -a short on the line causes all iso- O. s'7r O Volume Setting Cut/remove jumper for <br /> 0 Default=High Fire plus CO <br /> lators to open within 23 msec o o.� Cut/remove <br /> -at 10 msec intervals, IP jumper for SIGA-AB4G: <br /> beginning on one side • - 1.- low dB <br /> OD CD Tone Setting <br /> :. Default=Temporal <br /> of the Class A DATA IN(- \ _z OM-DMA-DMA. <br /> DATA OUT(-) our IN IN/OUT Cut/remove jumper for <br /> circuit nearest the loop ITI ITT I I I ITI ° steady <br /> I( <br /> controller,the isolators �.�1r.1r.l.,l <br /> DATA OUT(+) I t�l� .r.. :rrt SIGA-AB4GT: <br /> close to provide the DATA IN(+) �To Next Device 0. 01 Not Used <br /> next isolator down the From Signature Controllertr.rl0+al,N�:�-}�mwl��mma <br /> or Previous Device 1111111 <br /> line with power Term Description <br /> 1 Not Used 24 Vdc in-when the isolator next 2 DATA IN/OUT(+) From power supply ■ IMI - 24 Vdc out <br /> to the short closes,it reopens within 10 3 DATA IN(-) or previous base + <br /> 4 Not Used NM + To next base a EOL relay <br /> msec. 5 Not Used <br /> 6 DATA OUT(-) Data in _ Data out <br /> The process repeats beginning on the 7 Not Used From Signature Controller to next Signature device <br /> other side of the loop controller.- or previous device + + <br /> • <br /> Page 3 of 4 0 AT I: S t-=S,` T E8 3 01-064 7 <br /> Not to bo usod fo,;ntDoEolioo( =r N a/:r:, Issue 2.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.