My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Application Typical Wiring <br /> The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18 AWG(0.75mm2) <br /> mined by their sub-type code or"Personality Code".NORMALLY- to#12 AWG(2.5mm2)wire sizes.See Signature Loop Controller <br /> OPEN ALARM-LATCHING(Pesonality Code 1)is assigned by the catalog sheet for detailed wiring requirement specifications. <br /> factory; no user configuration is required.The device is configured <br /> for Class B IDC operation.An ALARM signal is sent to the loop Wiring Notes <br /> controller when the station's pull lever is operated.The alarm con- Refer to Signature Loop Controller manual-for maximum <br /> dition is latched at the station. wire distance. <br /> 2. All wiring is power limited-ancLsupervised__ <br /> Compatibility REAR VIEW _ <br /> of 278 <br /> Signature Series manual stations are compatible only with ED- <br /> WARDS's a <br /> Signature Loop Controller. p <br /> 0 <br /> 0 <br /> ream, <br /> IMAIMI j_ <br /> Warnings & Cautions 8® <br /> • • <br /> This device will not operate without electrical power.As fires fre- <br /> quently cause power interruption, we suggest you discuss further Red LEDGreen LED <br /> (Alarm/Active) ® a (Normd) <br /> safeguards with your local fire protection specialist. J 4 3 2 ' . <br /> o TB'Il,lil,.N li 1''''' O <br /> IC:- <br /> Testing & Maintenance _limi■u■imal_ <br /> To test(or reset)the station simply open the station and operate DATA IN(a) ' DATA OUT(+) <br /> the exposed switch.The SIGA-270 series are opened with a tool; {DATA IN(-) , DATA OUT(-)} <br /> the SIGA-278 requires the key which is supplied with that station. Rom Signature Controller To Next Device <br /> or Previous Device A <br /> The station's automatic self-diagnosis identifies when it is defec- <br /> tive and causes a trouble message.The user-friendly maintenance Figure 4. Single Stage Systems <br /> program shows the current state of each Signature series device <br /> and other pertinent messages. Single devices may be deactivated <br /> temporarily,from the control panel.Availability of maintenance <br /> features is dependent on the fire alarm system used. REAR VIEW <br /> of <br /> Scheduled maintenance(Regular or Selected)for proper system 270P,270PB 0 <br /> o <br /> operation should be planned to meet the requirements of the _— <br /> /. o <br /> Authority Having Jurisdiction (AHJ). Refer to current NFPA 72 and o r=.., <br /> Tee ,9l cr a�l�� <br /> ULC CAN/ULC 536 standards. ��- - �1.11 <br /> !I 8 7 6 5 <br /> to • • <br /> Red LED I II® Green LED <br /> (Alarm/Active) (Normd) <br /> 4 3 2 1 f <br /> Tel 11, 111111 - - - <br /> • o <br /> h �I h <br /> miDATA IN(n) , DATA OUT <br /> 1 DATA IN(-) , (+)DATA OUT(-)1 <br /> From Signature Controller To Next Device <br /> or Previous Device A <br /> Figure 5. Two Stage Systems <br /> Page 2 of 4 E85001-0279 <br /> issue 1.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.