My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
916 PACIFIC AVE MRI BUILDING 2024-04-15
>
Address Records
>
PACIFIC AVE
>
916
>
MRI BUILDING
>
916 PACIFIC AVE MRI BUILDING 2024-04-15
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2024 8:12:28 AM
Creation date
4/11/2024 1:10:04 PM
Metadata
Fields
Template:
Address Document
Street Name
PACIFIC AVE
Street Number
916
Tenant Name
MRI BUILDING
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
157
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EN54 Compliance <br /> EST3 has passed the British-based Loss Prevention Certification <br /> ID L A O Board(LPCB)certified EST3 control panels and power supplies as <br /> _ having surpassed the requirements of the pivotal EN54 standard, <br /> Alarm *upervisory OEM Monitor parts two and four as well as part 16. LPCB Certificate#262ab In <br /> order to meet these standards,display and control functions have <br /> Priority order is alarm, supervisory,trouble, monitor. By using undergone slight modifications for the EN54 marketplace.These <br /> queues an emergency user does not waste time scrolling through differences are highlighted below.All other control and annunciation <br /> a mixed event list looking for alarms or confusing an alarm mes- features remain unchanged. <br /> sage with other message types. Note: EN 54-2: 1997+Al: 2006, EN 54-4: 1997+Al: 2002+ <br /> EST3 configures for Remote proprietary system operation where A2: 2006,and EN 54-16: 2008. <br /> every event must be acknowledged by viewing them before the <br /> internal buzzer will silence. Or the EST3 will configure for Local <br /> operation. Here the internal buzzer silences by pressing panel System Status LEDs <br /> silence. If any events exist in queues that have not been viewed <br /> the queue LED continues to flash informing the user of un-seen <br /> Power Test CPU Sounder Disable <br /> events. <br /> Fault <br /> When all events in a queue are acknowledged or'seen',the <br /> LED associated with the queue turns on steady. If a new event is Power LED(Green): on when DC power is on. <br /> added to the queue, the EST3 internal buzzer resounds and the Test LED(Yellow): on when any portion of the system(Group)is <br /> queue LED flashes. under test. <br /> EST3 allows device grouping into logical group zones. Here two or CPU Fault LED(Yellow): on when CPU stops running(processor <br /> more alarm devices(such as detectors or pull stations)make up failures must be manually reset). <br /> the zone.When a device in the zone activates,the LCD displays <br /> the zone description. Each zone only displays once, regardless of Gnd Fault LED: Not available. <br /> the number of devices active within the zone. Sounder LED(Yellow):flashing indicates fault on sounder circuit. <br /> Details To display device information the user presses Steady indicates a disabled sounder circuit. <br /> the Details key.The device with the lowest Disable LED (Yellow): on when any point or zone is disabled by <br /> address displays in the first window. a user(disabled conditions have priority over fault conditions). <br /> If multiple devices are active each is available for viewing by using <br /> the arrow associated with the Previous Message Next key and Switch Functions <br /> scrolling through the device list. ' ` founder Panel <br /> Reset On/Off Silence Drill <br /> 17 R I n D E NU The common controls easily <br /> Ii 11 5TRTLI5 expand beyond the Main Display <br /> 3 D E I S RBL1"L ❑ 1111:1 <br /> l interface by adding a Control C I ❑� I ❑) <br /> 3J 1 E <br /> 41 RCTJVRTE Display Module and assigning <br /> 5) RESTORE features to its switch controls. <br /> 61 REPORTS Pressing Sounder On/Off turns off all sounder circuits defined as <br /> ROOD 5 o o o T o o o I1 o o D V For Maintenance users,the EST3 audible.The yellow LED turns on when silence is activated via the <br /> provides a smooth operating Sounder On/Off or via the alarm silence software timers. <br /> menu system providing powerful tools for system management, <br /> reports, and trouble shooting. See Page 2 for descriptions of Reset, Panel Silence, and Drill func- <br /> tions. <br /> Installation and Mounting Event Queues <br /> A/ 0 [.4/ DI •,/ u A/ C <br /> -4 r Fire Fault Disable Monitor <br /> L cc <br /> Central M • For EN54 compliance, EST3 configures for remote proprietary <br /> Processor - -1 T - system operation.This requires that every event must be acknowl- <br /> Unit <br /> 3-CPU - CID CCedged by viewing them before the internal buzzer will silence.The <br /> �BB� = ® CM— ® ® Iti 1 Fri priority order is Fire, Fault, Disable, Monitor. <br /> 1110.11EA--I i <br /> a _ _ _ <br /> En ED <br /> \i-,.. ®®®® = CID I: <br /> CC in Fil <br /> _® <br /> vn pi <br /> a�� <br /> Ali■ 00 <br /> BOe 00 <br /> OD CO <br /> Page 3 of 4 E85010_0071 <br /> issue 1.1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.