Laserfiche WebLink
EN54 Compliance <br /> EST3 has passed the British-based Loss Prevention Certification <br /> ID L A O Board(LPCB)certified EST3 control panels and power supplies as <br /> _ having surpassed the requirements of the pivotal EN54 standard, <br /> Alarm *upervisory OEM Monitor parts two and four as well as part 16. LPCB Certificate#262ab In <br /> order to meet these standards,display and control functions have <br /> Priority order is alarm, supervisory,trouble, monitor. By using undergone slight modifications for the EN54 marketplace.These <br /> queues an emergency user does not waste time scrolling through differences are highlighted below.All other control and annunciation <br /> a mixed event list looking for alarms or confusing an alarm mes- features remain unchanged. <br /> sage with other message types. Note: EN 54-2: 1997+Al: 2006, EN 54-4: 1997+Al: 2002+ <br /> EST3 configures for Remote proprietary system operation where A2: 2006,and EN 54-16: 2008. <br /> every event must be acknowledged by viewing them before the <br /> internal buzzer will silence. Or the EST3 will configure for Local <br /> operation. Here the internal buzzer silences by pressing panel System Status LEDs <br /> silence. If any events exist in queues that have not been viewed <br /> the queue LED continues to flash informing the user of un-seen <br /> Power Test CPU Sounder Disable <br /> events. <br /> Fault <br /> When all events in a queue are acknowledged or'seen',the <br /> LED associated with the queue turns on steady. If a new event is Power LED(Green): on when DC power is on. <br /> added to the queue, the EST3 internal buzzer resounds and the Test LED(Yellow): on when any portion of the system(Group)is <br /> queue LED flashes. under test. <br /> EST3 allows device grouping into logical group zones. Here two or CPU Fault LED(Yellow): on when CPU stops running(processor <br /> more alarm devices(such as detectors or pull stations)make up failures must be manually reset). <br /> the zone.When a device in the zone activates,the LCD displays <br /> the zone description. Each zone only displays once, regardless of Gnd Fault LED: Not available. <br /> the number of devices active within the zone. Sounder LED(Yellow):flashing indicates fault on sounder circuit. <br /> Details To display device information the user presses Steady indicates a disabled sounder circuit. <br /> the Details key.The device with the lowest Disable LED (Yellow): on when any point or zone is disabled by <br /> address displays in the first window. a user(disabled conditions have priority over fault conditions). <br /> If multiple devices are active each is available for viewing by using <br /> the arrow associated with the Previous Message Next key and Switch Functions <br /> scrolling through the device list. ' ` founder Panel <br /> Reset On/Off Silence Drill <br /> 17 R I n D E NU The common controls easily <br /> Ii 11 5TRTLI5 expand beyond the Main Display <br /> 3 D E I S RBL1"L ❑ 1111:1 <br /> l interface by adding a Control C I ❑� I ❑) <br /> 3J 1 E <br /> 41 RCTJVRTE Display Module and assigning <br /> 5) RESTORE features to its switch controls. <br /> 61 REPORTS Pressing Sounder On/Off turns off all sounder circuits defined as <br /> ROOD 5 o o o T o o o I1 o o D V For Maintenance users,the EST3 audible.The yellow LED turns on when silence is activated via the <br /> provides a smooth operating Sounder On/Off or via the alarm silence software timers. <br /> menu system providing powerful tools for system management, <br /> reports, and trouble shooting. See Page 2 for descriptions of Reset, Panel Silence, and Drill func- <br /> tions. <br /> Installation and Mounting Event Queues <br /> A/ 0 [.4/ DI •,/ u A/ C <br /> -4 r Fire Fault Disable Monitor <br /> L cc <br /> Central M • For EN54 compliance, EST3 configures for remote proprietary <br /> Processor - -1 T - system operation.This requires that every event must be acknowl- <br /> Unit <br /> 3-CPU - CID CCedged by viewing them before the internal buzzer will silence.The <br /> �BB� = ® CM— ® ® Iti 1 Fri priority order is Fire, Fault, Disable, Monitor. <br /> 1110.11EA--I i <br /> a _ _ _ <br /> En ED <br /> \i-,.. ®®®® = CID I: <br /> CC in Fil <br /> _® <br /> vn pi <br /> a�� <br /> Ali■ 00 <br /> BOe 00 <br /> OD CO <br /> Page 3 of 4 E85010_0071 <br /> issue 1.1 <br />