Application Dimensions <br /> The BPS provides additional power and circuits for notification ap- <br /> pliances and other 24 Vdc loads. It is listed for indoor dry locations D5 0 <br /> O O <br /> and can easily be installed where needed. Top View <br /> Fault conditions are indicated on the on-board diagnostic LEDs, <br /> opening the BPS input sense circuit and the trouble relay(if H D2 H f -- D3- <br /> programmed).While this provides indication to the host system, _ <br /> the BPS can still be activated upon command.A separate AC <br /> Fail contact is available on the BPS circuit board,which can be or D4 �o 1 <br /> o ° ° o— <br /> programmed for trouble or AC Fail.There are seven on-board <br /> diagnostic LEDs:one for each NAC fault,one for battery fault,one m Front View 0 <br /> for ground fault,and one for AC power. > <br /> I <br /> The unique dual-input activation circuits of the BPS can be acti- <br /> vated by any voltage from 6 to 45 VDC(filtered-regulated)or 11 0 <br /> D1 D6 <br /> to 33 Vdc(full-wave rectified, unfiltered).The first input circuit can 0 ° <br /> be configured to activate 1-4 of the four possible outputs.The E. <br /> second input circuit can be configured to control circuits 3 and 4. All knockouts <br /> When outputs are configured for auxiliary operation,these circuits for 3/4 in conduit < <br /> 3can be configured to stay on or automatically deactivate 30 sec- ° (1.9 cm) ° I * <br /> onds after AC power is lost.This feature makes these circuits ideal o <br /> for door holder applications.The BPS also has a separate 200 i <br /> mA 24 Vdc output that can be used to power internal activation I - :mm. <br /> modules. <br /> BPS NACs can be configured for a 3-3-3 temporal or continuous Di D2 D3 D4 D5 D6 <br /> output.This makes the BPS ideal for applications requiring signal- 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in <br /> ing rates that are not available from the main system. (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) <br /> In addition to the internally generated signal rates,the BPS can <br /> also be configured to follow the coded signal rate of the main <br /> system NACs.This allows for the seamless expansion of existing Wire routing Power-limited <br /> NACs. wiring area <br /> The BPS enclosure has mounting brackets for up to three Signa- <br /> ture modules to the right of the circuit board. I <br /> Engineering Specification 111111 1.1,111, li :---• <br /> E -[2] <br /> Supply,where needed, EDWARDS BPS Series Booster Power FI IN — <br /> Supplies(BPS)that are interconnected to and supervised by the ° o° <br /> main system.The BPS shall function as a stand-alone auxiliary I ❑cl : _ <br /> r:a <br /> power supply with its own fully-supervised battery compliment. • ■ <br /> le r_, <br /> The BPS battery compliment shall be sized to match the require- a•--- �,[3] • <br /> ments of the main system.The BPS shall be capable of supervis- Route AC supply - •�, * I. °°°°°°F o <br /> ing and charging batteries having the capacity of 24 ampere-hours through these — " `-==e ° _ <br /> for Mass Notification/Emergency Communication(MNEC), life knockouts only ■ ■ <br /> safety applications. (Nonpower-limited '.' J. A. ALand supervised) Battery wiring (nonpower- <br /> «The BPS shall be capable of installation for a seismic corn- limited and supervised) <br /> ponent Importance Factor of 1.5.»The BPS shall provide a <br /> minimum of four independent,fully supervised Class B circuits Battery Battery <br /> that can be field configurable for notification appliance circuits or <br /> auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to <br /> a minimum of two Class A NACs. Each BPS output circuit shall be <br /> rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- <br /> vided with automatically restoring overcurrent protection.The BPS Notes <br /> shall be operable from the main system NAC and/or EDWARDS 1. Maintain 1/4-inch(6 mm)spacing between power-limited and nonpower-limited <br /> wiring or use type FPL,FPLR,or FPLP cable per NEC. <br /> Signature Series control modules. BPS NACs shall be configurable <br /> [2] Power-limited and supervised when not configured as auxiliary power.Non- <br /> for continuous or 3-3-3 temporal rate. Fault conditions on the BPS supervised when configured as auxiliary power. <br /> shall not impede operation of main system NAC.The BPS shall be [3] Source must be power-limited.Source determines supervision. <br /> provided with ground fault detection circuitry and a separate AC 4. When using larger batteries,make sure to position the battery terminals towards <br /> fail relay. the door. <br /> Page 2 of 4 E85005-0125 <br /> Issue 1.2 <br />