Laserfiche WebLink
EVERETT <br /> WAC 29646B=900 : ELECTRICAL PLAN REVIEW <br /> WASHINGTON <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required. Then select the box next to (a) <br /> to tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-4613-900. If plan review <br /> is required, select the box next to (b) and (c) to acknowledge that plan review is required and the electrical plans have been <br /> provided with this permit application. <br /> * If item (a)-(ii, iii, or v) is selected, the work must also comply with section (a)-(vii). See arrow flow chart below. <br /> (3) Electrical plan review. <br /> F#/J (a) Electrical plan review is not required for: <br /> 0 (i) Low voltage systems; <br /> �❑ (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> �----� (iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> (iv) Stand-alone utility fed services that do not exceed 250 volts, 400 amperes where the project's distribution <br /> system does not include: <br /> (A) Emergency systems other than listed unit equipment per NEC 700. 12(F); <br /> (B) An essential electrical system defined in NEC 517.2; or <br /> (C) A required fire pump system. <br /> [] (v) Modifications to existing electrical installations where all of the following conditions are met: <br /> (A) Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground, <br /> (B) Does not involve emergency systems other than listed unit equipment per NEC 700. 12(F); <br /> (C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC <br /> 517.2; and <br /> (D) Service or feeder load calculations are increased by 5% or less. <br /> (vi) Electric power production source(s) such as solar photovoltaic, fuel cell, or wind electric system(s) with a total <br /> rating of 9600 watts or less. <br /> (vii) For installations in (a)(ii), (iii), and (v) of this subsection to be considered, the following must be <br /> available to the electrical inspector before the work is initiated: <br /> (A) A clear and adequate description of the project's scope; <br /> (B) A load calculation(s); <br /> (C) What the load changes are, providing both before and after panel schedules as needed; and <br /> (D) Provide information showing that the service and feeder(s) supplying the panel(s) where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent <br /> protection for that supply. <br /> NOTE: Electrical plan review is not required for "Medical, dental, and chiropractic clinic" of which is a clinic or <br /> ` [{ physicians' office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1 )(c)(xli). <br /> (b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br /> occupancies defined In this chapter. <br /> (c) if a review is required, the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Table 900-1 <br /> Table 900-2 <br /> Health or Personal Care Facilities Educational acid Institutional Facilities, Places of Assembly, or otherFacllities <br /> Health or Personal Care Facility Plan Review <br /> "hype Required Educational, institutional, or Plan Review <br /> i-lo itai Other�he� Facility TypesRequire4 <br /> ~4u 'srngne unitor lertg-tern^ �Ye= Educational Yes <br /> care t.igtit Institutis nal <br /> Soardinq home ye3 <br /> kssisted living facility vee <br /> Privav= alcoholism ho;pita YeS Notes to Tabfes 900-1 and 9M2. <br /> rlvate psych atr c nosp.tal ye_, ` , A city, authorized to do electrical inspections <br /> 't4atern ity home Ye_ may require plan review on facihW types not <br /> Arnbu ator,, surgery facility Yes reviewed by the department. <br /> enai her--)1=iia'ysi= clinic Yet <br /> Residen-U&I t`eatn<ent fa Cilli '3 YF= <br /> _nhanced _erg ice facility Yes <br /> Adult residential rehabilitation Yes PERMIT# Page 2-Plan Review <br /> center <br />