Application Dimensions <br /> The BPS provides additional power and circuits for notification ap- <br /> pliances and other 24 Vdc loads. It is listed for indoor dry locations D5 0 <br /> and can easily be installed where needed. Top View <br /> Fault conditions are indicated on the on-board diagnostic LEDs, <br /> opening the BPS input sense circuit and the trouble relay(if D2 H 4 D3 H <br /> programmed).While this provides indication to the host system, • 1 J l� <br /> the BPS can still be activated upon command.A separate AC <br /> Fail contact is available on the BPS circuit board,which can be a® D4�o <br /> programmed for trouble or AC Fail.There are seven on-board <br /> diagnostic LEDs:one for each NAC fault, one for battery fault,one 0 Front View 0 <br /> for ground fault,and one for AC power. <br /> a) • <br /> The unique dual-input activation circuits of the BPS can be acti- -a <br /> vated by any voltage from 6 to 45 VDC(filtered-regulated)or 11 D 1 O D6 <br /> to 33 Vdc(full-wave rectified, unfiltered).The first input circuit can O <br /> be configured to activate 1-4 of the four possible outputs.The a <br /> second input circuit can be configured to control circuits 3 and 4. All knockouts (1)When outputs are configured for auxiliary operation,these circuits for 3/4 in conduit < <br /> CD <br /> can be configured to stay on or automatically deactivate 30 sec- ° (1.9 cm) ° <br /> ends after AC power is lost.This feature makes these circuits ideal 0 <br /> for door holder applications.The BPS also has a separate 200 <br /> mA 24 Vdc output that can be used to power internal activation ♦ I t I mi <br /> modules. <br /> BPS NACs can be configured for a 3-3-3 temporal or continuous Di D2 D3 D4 D5 D6 <br /> output.This makes the BPS ideal for applications requiring signal- 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in <br /> ing rates that are not available from the main system. (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) <br /> In addition to the internally generated signal rates,the BPS can <br /> also be configured to follow the coded signal rate of the main <br /> system NACs.This allows for the seamless expansion of existing Wire routing Power-limited <br /> NACs. <br /> wiring area <br /> The BPS enclosure has mounting brackets for up to three Signa- <br /> ture modules to the right of the circuit board. ° <br /> 8 -1 ,,_J-- <br /> o° <br /> Engineering Specification <br /> Supply,where needed, EDWARDS BPS Series Booster Power <br /> Supplies(BPS)that are interconnected to and supervised by the , i — . °o° ■ <br /> main system.The BPS shall function as a stand-alone auxiliary Q <br /> power supply with its own fully-supervised battery compliment. •a — (3) r <br /> The BPS battery compliment shall be sized to match the require •o <br /> ments of the main system.The BPS shall be capable of supervis- Route AC supply •.,•�•rI �� o° <br /> ing and charging batteries having the capacity of 24 ampere-hours through these • u ° <br /> for Mass Notification/Emergency Communication(MNEC),life knockouts only 44 t J '`'M <br /> safety applications. (Nonpower-limited <br /> and supervised) Battery wiring (nonpower- <br /> «The BPS shall be capable of installation for a seismic corn- o limited and supervised) o <br /> ponent Importance Factor of 1.5.»The BPS shall provide a <br /> minimum of four independent,fully supervised Class B circuits Battery Battery <br /> that can be field configurable for notification appliance circuits or <br /> auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to <br /> a minimum of two Class A NACs. Each BPS output circuit shall be <br /> rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- _ <br /> vided with automatically restoring overcurrent protection.The BPS Notes <br /> shall be operable from the main system NAC and/or EDWARDS 1. Maintain 1/4-inch(6 mm)spacing between power-limited and nonpower-limited <br /> Signature Series control modules. BPS NACs shall be configurable wiring or use type FPL,FPLR,or FPLP cable per NEC. <br /> [2] Power-limited and supervised when not configured as auxiliary power.Non- <br /> for continuous or 3-3-3 temporal rate. Fault conditions on the BPS supervised when configured as auxiliary power. <br /> shall not impede operation of main system NAC.The BPS shall be [3] Source must be power-limited.Source determines supervision. <br /> provided with ground fault detection circuitry and a separate AC 4. When using larger batteries,make sure to position the battery terminals towards <br /> fail relay. the door. <br /> Page 2 of 4 E85005n-0 3 25 <br /> Issue 1.2 <br />