Laserfiche WebLink
Retrofit Description <br /> Provide blocking located at water damage area. The retrofit shall consist of 2x blocking, with 16d <br /> common nails at 24" O.C., staggered. Blocking shall begin and end between 0" and 18" from rafter <br /> ends and should happen before install. <br /> Additional Retrofit Details and Notes <br /> ROOF SHEATHING <br /> NEW 2 x BLOCKING AT 48" <br /> O.C.OR AT OTHER SPACING <br /> AS NOTED IN LETTER <br /> RIDGEBOARD <br /> 2 x RAFTER <br /> TOENAIL NEW BLOCKING INTO <br /> EXISTING WITH(2)16d NAILS AT <br /> EACH CONNECTION.DO NOT <br /> PENETRATE PLYWOOD ABOVE. <br /> 2 x CEILING JOIST DETAIL NOTES: <br /> 1.ALL MEMBERS SHOWN ARE EXISTING <br /> UNLESS LABELED(N)OR NEW. <br /> 2. RETROFIT REQUIRED ONLY AT ROOF <br /> AREAS SUPPORTING SOLAR PANELS AND <br /> BEARING WALL THAT ARE SAGGING OR SOFT, UNLESS <br /> NOTED OTHERWISE IN LETTER. <br /> Pictures of poor condition - area to be retrofit (where applies) <br /> -+sem !! S7ly <br /> � T <br />