My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1302 SE EVERETT MALL WAY TRADER JOES 2025-07-11
>
Address Records
>
SE EVERETT MALL WAY
>
1302
>
TRADER JOES
>
1302 SE EVERETT MALL WAY TRADER JOES 2025-07-11
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/11/2025 11:54:21 AM
Creation date
4/23/2024 9:18:29 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1302
Tenant Name
TRADER JOES
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2 3 4 5 6 <br /> -COFFMAN <br /> ENGINEERS <br /> GENERAL LEGEND ABBREVIATIONS PIPING LEGEND 1101 2nd Avenue, <br /> SYMBOL DESCRIPTION ABBR DESCRIPTION ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION SYMBOL ABBR DESCRIPTION Suite 400 <br /> Seattle,WA 98101 <br /> A DETAIL SYMBOL A = IDENTIFYING NUMBER ABV ABOVE L LENGTH W WASTELIGHT LINEWORK INDICATES CAP PIPE END CAP <br /> AD ACCESS DOOR LAT LEAVING AIR TEMPERATURE W/ WITH EXISTING PIPING OR EQUIPMENT ph 206.623.0717 <br /> B B = SHEET WHERE DETAIL IS SHOWN AHU AIR HANDLING UNIT LBS POUNDS W/O WITHOUT -0 PIPE TURNING DOWN OR AWAY <br /> AL ACOUSTIC LINED LF LINEAR FOOT/FEET WB WET BULB INDICATES PIPING OR EQUIPMENT <br /> AP ACCESS PANEL LVG LEAVING WCO WALL CLEANOUT TO BE REMOVED 0 PIPE TURNING UP OR TOWARD <br /> DETAIL SYMBOL A = IDENTIFYING NUMBER www.coffman.com <br /> A APD AIR PRESSURE DROP LWG LOW WALL GRILLE WG WATER GAGE SS SS SANITARY SEWER-OUTSIDE BUILDING AND � PIPE TURNING DOWN OR AWAY(TEE) <br /> B C B =SHEET WHERE DETAIL IS TAKEN ARCH ARCHITECT/ARCHITECTURAL LWR LOW WALL REGISTER WGE WASTE GAS EVACUATION BELOW GROUND <br /> C =SHEET WHERE DETAIL IS SHOWN ARV AUTOMATIC RELIEF VALVE or LWT LEAVING WATER TEMPERATURE WPD WATER PRESSURE DROP SD SD STORM DRAIN-OUTSIDE BUILDING AND REDUCER(NOT TYPICALLY SHOWN) <br /> ACID RESTISTANT VENT WT WEIGHT BELOW GROUND PIPE CONNECTION <br /> ARW ACID RESTISTANT WASTE MAX MAXIMUM <br /> E W WASTE(&SOIL)-ABOVE GROUND-INTERIOR E 1�D N <br /> A SECTION SYMBOL: A = IDENTIFYING LETTER MBH 1000 BRITISH THERMAL v A <br /> BDD BACKDRAFT DAMPER UNITS PER HOUR PIPE ANCHOR <br /> B B =SHEET WHERE SECTION IS SHOWN W WASTE(&SOIL)-BELOW GROUND-INTERIOR <br /> BFP BACKFLOW PREVENTER MCC MOTOR CONTROL CENTER (NOT ALWAYS SHOWN,SEE SPECIFICATIONS) <br /> BHP BRAKE HORSEPOWERMECH MECHANICAL — — — — — V VENT ' iji-1-111A <br /> BGBELOW GROUNDMFR MANUFACTURERARW ACID RESISTANT WASTE PIPE ALIGNMENT GUIDES&I BETWEEN JOISTS MIN MINIMUM (NOT ALWAYS SHOWN,SEE SPECIFICATIONS) OaSECTION SYMBOL: A = IDENTIFYING LETTER BTU BRITISH THERMAL UNIT mm MISCELLANEOUS —ARV— ARV ACID RESISTANT VENT HB HOSE BIBB NB =SHELT WHERE SECTION IS TAKEN BTUH BRINSH THERMAL UNTIS PER HOUR MTD MOUNTEDC =SHEET WHERE SECTION IS SHOWN MTG MOUNTING CW COLD WATER-DOMESTIC <br /> C CENTIGRADE HW HOT WATER-DOMESTIC � WH/NFWH WALL HYDRANT or NON-FREEZE WALL HYDRANT 7;822 <br /> CC COOLING COIL N/A NOT APPLICABLE HWC HOT WATER CIRCULATING-DOMESTIC 'I CO/WCO CLEANOUT or WALL CLEANOUT <br /> CD CEILING DIFFUSER N/C NORMALLY CLOSED --- <br /> SECTION CUT UNE INDICATOR CFM CUBIC FEET PER MINUTE N/0 NORMALLY OPEN RD RD RAINWATER DRAINAGE-ABOVE GROUND FCO/SCO FLUSH CLEANOUT or SURFACE CLEANOUT <br /> CG CEILING GRILLE NC NOISE CRITERIA <br /> O <br /> CI CAST IRON NIC NOT IN CONTRACT RD RD RAINWATER DRAINAGE-BELOW GROUND FDC FIRE DEPARTMENT CONNECTION KEYED REFERENCE NOTE OR SHEET NOTE CLG CEILING NTS NOT TO SCALE ORD ORD RAINWATER DRAINAGE OVERFLOW-ABOVE GROUND <br /> CO CLEANOUT p FIRE SPRINKLER ALARM GONG <br /> 0 POINT OF CONNECTION(POC)SYMBOL CONC CONCRETE OA OUTSIDE AIR ORD ORD RAINWATER DRAINAGE OVERFLOW-BELOW GROUND <br /> CONN CONNECT or CONNECTION OBD OPPOSED BLADE DAMPER ® AD AREA DRAIN <br /> P1-1 PLUMBING FIXTURE REFERENCE(REFER TO SCHEDULE) CONST CONSTRUCTION 0/C ON CENTER D D DRAIN -INDIRECT <br /> CONT CONTINUATION OD OUTSIDE DIAMETER —RV— RV RELIEF VALVE VENT ® FD or FFD FLOOR DRAIN or FUNNEL FLOOR DRAIN <br /> AHU-1 EQUIPMENT IDENDFlCATION REFER TO SCHEDULES CR CONDENSATE RETURN OPNG OPENING FS FLOOR SINK <br /> D ( ) PIPE SLOPE DIRECTION <br /> DB DECIBLE or DRY BULB PCV PRESSURE CONTROL VALVE f @o OD OVERFLOW DRAIN <br /> OA MEDICAL GAS OUTLET IDENTIFICATION(REFER TO SCHEDULE) DDC DIRECT DIGITAL CONTROL PD PRESSURE DROP —ICW-- ICW INDUSTRIAL COLD WATER <br /> DIA DIAMETER PH or 0 PHASE —SCW - SCW SOFT COLD WATER OO RD ROOF DRAIN <br /> DIM DIMENSION PLCS PLACES —TCW-- FCW COLD WATER(FLUSHING SYSTEM) D< SHUTOFF VALVE(AS SPECIFIED FOR PIPING SYSTEM) <br /> MEDICAL GAS ZONE VALVE STATION MOUNTED IN WALL DN DOWN POC POINT OF CONNECTION <br /> DPR DAMPER POUA POINT OF USE ALARM ---Ai WW -- IHW INDUSTRIAL HOT WATER Dm BV BALL VALVE <br /> DWG DRAWING PRV PRESSURE REDUCING VALVE <br /> MEDICAL GAS ALARM PANEL MOUNTED IN WALL PSI POUNDS PER SQUARE INCH —KHW--- KHW KITCHEN HOT WATER Tv CKV CHECK VALVE <br /> E-100 EXHAUST AIR PSIG POUNDS PER SQUARE INCH GAGE I\I BFV BUTTERFLY VALVE <br /> NUMBER INDICATES CFM QUANTITY —KHWC ---- KHWC KITCHEN HOT WATER CIRCULATING <br /> MEDICAL GAS OUTLET EA EACH R-100 RETURN AIR —LHW--- LHW LAUNDRY HOT WATER I*I BFV BUTTERFLY VALVE W/MEMORY STOP <br /> ms <br /> EAT ENTERING AIR TEMPERATURE NUMBER INDICATES CFM QUANTITY <br /> EF EXHAUST FAN RA RETURN AIR —LHWC ---- LHWC LAUNDRY HOT WATER CIRCULATING DkI BAL VA BALANCING VALVE <br /> D EG EXHAUST GRILLE RAG RETURN AIR GRILLE NPW NPW NON-POTABLE WATER CFI BSV COMBINATION BALANCING/SHUTOFF VALVE C <br /> 1 <br /> REVISION CLOUD AND REVISION NUMBER ELEC ELECTRIC or ELECTRICAL READ REQUIRED <br /> ELEV ELEVATION �W IW IRRIGATION WATER <br /> RPBP REDUCED PRESSURE BACKFLOW ACV 2-WAY MODULATING CONTROL VALVE W/ACTUATOR <br /> EMCS ENERGY MANAGEMENT CONTROL SYSTEM <br /> PREVENTOR DI DI DEIONIZED WATER <br /> ESP EXTERNAL STATIC PRESSURE 19 ACV 3-WAY MODULATING CONTROL VALVE W/ACTUATOR <br /> XX BINARY(YES/NO)SENSING SWITCH ENT ENTERING WATER TEMPERATURE RPM REVOLUTIONS PER MINUTE DVI DW DISTILLED WATER <br /> (PIPE OR DUCT MOUNTED) IXST or(E) EXISTING S-100 SUPPLY AIR CS CS CONDENSER WATER SUPPLY 2-POSITION CONTROL VALVE <br /> NUMBER INDICATES CFM QUANTITY A PRV PRESSURE REDUCING VALVE <br /> F FAHRENHEIT SA SUPPLY AIR CR CR CONDENSER WATER RETURN <br /> 8> <br /> X BINARY(YES/NO)SENSING SWITCH FA FACE AREA SF SUPPLY FAN CWS CWS CHILLED WATER SUPPLY-COOUNG � RV RELIEF VALVE <br /> (SURFACE MOUNTED) FCO FLOOR CLEANOUT SHT SHEEP b FMS FLOW MEASUREMENT STATION <br /> FCU FAN COIL UNIT SIM SIMILAR CWR CWR CHILLED WATER RETURN-COOUNG <br /> XX ANALOG SENSING DEVICE FD FLOOR DRAIN SP STATIC PRESSURE RL RL LIQUID LINE-REFRIGERANT STIR Y-TYPE STRAINER <br /> (PIPE OR DUCT MOUNTED) FDPR FIRE DAMPER SQ SQUARE <br /> FFD FUNNEL FLOOR DRAIN SO FT SQUARE FOOT/FEET RS RS SUCTION LINE-REFRIGERANT W GLV GLOBE VALVE <br /> ANALOG SENSING DEVICE FF FINAL FILTER SS STAINLESS STEEL <br /> (SURFACE MOUNTED) FIR FLOOR STD STANDARD HG HG HOT GAS LINE-REFRIGERANT OSY VA OUTSIDE SCREW AND YOKE VALVE <br /> XX <br /> FPM FEET PER MINUTETHK THICK FPS FEET PER SECOND HWS HWS HOT WATER HEATING SUPPLY � IXP VA EXPANSION VALVE <br /> Q ANALOG SENSING DEVICE(SURFACE MOUNTED) FT FOOT/FEET TP TRAP PRIMER or TEST PLUG HWR HWR HOT WATER HEATING RETURN <br /> (APPROPRIATE FOR MEASURED FLUID) FV FACE VELOCITY TYP TYPICAL FOS FOS FUEL OIL SUPPLY ID FCV FLOW CONTROL VALVE EVERETT MALL <br /> SUBSCRIPT LETTER(X)INDICATES: TU TERMINAL UNIT FOR FOR FUEL OIL RETURN III UNION RENOVATION <br /> A-ALARM PRESSURE SENSOR GA GAGE or GAUGE <br /> D-DIFFERENTIAL PRESSURE GAL GALLON UBC UNIFORM BUILDING CODE G GNATURAL GAS �� FLANGES <br /> F-FLOW RATE GALV GALVANIZED UFC UNIFORM FIRE CODE PHASE 1 <br /> H-HUMIDITY GPH GALLONS PER HOUR UMC UNIFORM MECHANICAL CODE LPG LPG LIQUID PETROLEUM GAS <br /> L-LOW LIMIT GPM GALLONS PER MINUTE UNO UNLESS OTHERWISE NOTED b THREADED DRAIN PLUG <br /> P-PRESSURE(STATIC) UPC UNIFORM PLUMBING CODE LPS LPS LOW PRESSURE STEAM SUPPLY 1 MALE(GARDEN)HOSE CONNECTION WITH CAP <br /> T-TEMPERATURE H HEIGHT UG UNDERGROUND LPR LPR LOW PRESSURE STEAM CONDENSATE RETURN <br /> V-VELOCITY&VOLUME FLOW RATE HD HEAD UH UNIT HEATER <br /> HP HORSEPOWER MPS MPS(20) MEDIUM PRESSURE STEAM SUPPLY Q TP TEST PLUG <br /> HTG HEATING VA VALVE NUMBER IN PARENTHESIS INDICATES PSI <br /> HVAC HEATING,VENTILATION AND VAC VACUUMMPR SHOCK ARRESTOR <br /> AIR CONDITIONING VAV VARIABLE AIR VOLUME MPR(20) MEDIUM PRESSURE STEAM CONDENSATE RETURN <br /> VD VOLUME DAMPER NUMBER IN PARENTHESIS INDICATES PSI <br /> HWG HIGH WALL GRILLE HPS HPS(100) HIGH PRESSURE STEAM SUPPLY �T TH or TI THERMOMETER(TEMPERATURE INDICATOR) <br /> HWR HIGH WALL REGISTER VEL VELOCITY NUMBER IN PARENTHESIS INDICATES PSI <br /> C H2 HERR VFD VARIABLE FREQUENCY DRIVE NUMBER 1402 SE EVERETT <br /> VTR VENT THRU ROOF HPR HPR(100) HIGH PRESSURE STEAM CONDENSATE RETURN D B STIR BASKET STRAINER <br /> NUMBER IN PARETHESIS INDICATES PSI MALL WAY <br /> PR PR STEAM CONDENSATE RETURN(PUMPED) P PI PRESSURE INDICATOR <br /> ATVATV ATMOSPHERIC VENT EVERETT, WA 98208 <br /> MA MA COMPRESSED MEDICAL AIR AAV AUTOMATIC AIR VENT <br /> U LA COMPRESSED LABORATORY AIR Q MANUAL AIR VENT <br /> MV MV MEDICAL VACUUM <br /> 02 02 OXYGEN ® PUMP(DIAGRAM) <br /> N20 N20 NITROUS OXIDE <br /> N2 N2 NITROGEN LN1 FLEXIBLE CONNECTOR <br /> 002 CO2 CARBON DIOXIDE <br /> A A COMPRESSED AIR INDICATES ASSEMBLY OF PIPING COMPONENTS <br /> (AS NOTED OR DIAGRAMED) <br /> V V VACUUM <br /> LV LV LABORATORY VACUUM <br /> WGE WGE WASTE GAS EVACUATION <br /> DRAWING INDEX <br /> DWG.N0. I TITLE <br /> Po01 PLUMBING COVER SHEET AND GENERAL INFO <br /> B P002 PLUMBING GENERAL NOTES B <br /> 2 P003 PLUMBING SCHEDULES <br /> o P100 BELOW GRADE PLUMBING PLAN- DEMO <br /> P101 PLUMBING FLOOR PLM!-DEMO <br /> P102 PLUMBING ROOF PLAN-DEMO <br /> P200 BELOW GRADE PLUMBING PLAN <br /> P201 PLUMBING FLOOR PLAN <br /> P202 PLUMBING ROOF PLAN <br /> a <br /> P301 PLUMBING DETAILS <br /> 07/08/22 50%DD SET <br /> 5 REV DATE DESCRIPTION <br /> PROJ.NO. 221522 <br /> 'o DRAWN CEI <br /> 3 CHECKED ON <br /> DATE 06/27/22 <br /> 3 <br /> ©COFFMAN ENGINEERS INC. <br /> SHEET TITLE: <br /> PLUMBING COVER <br /> SHEET AND <br /> aA A GENERAL <br /> INFORMATION <br /> 0rE <br /> SHEET NO: <br /> 0 <br /> P001 <br /> a <br /> a SHEET X OF XXX <br /> 1 2 3 4 5 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.