SYSTEM DESIGNATIONS PANEL NOMENCLATURE ABBREVIATIONS LIGHTING FIXTURE SCHEDULE <br /> X 3 V34-1 U D12 A D NOTE: SEE SHEET E506 FOR FIRE ALARM ABBREVIATIONS TYPE DESCRIPTION VOLTAGE WATTS MFG/NUMBER LAMP LOCATION NOTES <br /> HASH MARKS INDICATE THE QUANTITY OF I SUFFIX "D" INDICATES A C AIR CONDITIONING PE PRESSURE ELECTRIC <br /> CONDUCTORS (#12 WIRE UNO.). IF UNMARKED DISTRIBUTION PANEL AC ALTERNATING CURRENT PB PUSHBUTTON <br /> / KIRLIN <br /> INSTALL 212 IN 1/2-CONDUIT CUSTOM BUILT 2'x 2' RECESSED LUMINARE 277 1000 STERNER BALLAST ASSEMBLY METAL HALIDE HIGH BAY RECESSED <br /> PHASE ONDUCTOORS SUFFIX "A , BOR C" A.F.F. ABOVE FINISHED FLOOR PR PAIR A <br /> NEUTRAL CONDUCTOR(IF REQUIRED) IDENTIFIES A SPECIFIC A.R.F. ABOVE RAISED FLOOR QTY QUANTITY <br /> GROUND CONDUCTOR(IF REQUIRED) PANELSPANEL WHEN OCCUREIN ONE ERAL AWG AMERICAN WIRE GAUGE RECP RECEPTACLE <br /> LOCATIONAMP AMPERE REF REFERENCE <br /> . <br /> 3V34-1J16/7,9,11 APPROX APPROXIMATE REQ'D REQUIRED B CUSTOM BUILT 2'x 2' RECESSED LUMINARE 277 400 KIRLIN METAL HALIDE LOW BAY RECESSED <br /> 3/4-C,3#8 PANEL HOME-RUN PANEL LOCATION ARCH ARCHITECT OR ARCHITECTURAL REV REVISION <br /> AT NEAREST COLUMN STERNER BALLAST ASSEMBLY <br /> PANEL/CIRCUIT AUTO AUTOMATIC RGS RIGID GALVANIZED STEEL <br /> CONDUIT/CONDUCTORS LOCATION OF PANEL WHEN ABOVE AUX AUXILIARY RM ROOM <br /> FIRST FLOOR: BOT BOTTOM SECT SECTION WIDEUTE <br /> CONDUIT RUN EXPOSED TN=TUNNEL, U=2ND FLOOR, V=3RD FLOOR BLDG BUILDING SHT SHEETC EXISTING FLOOD LIGHTS TO BE REPLACED WITH 277V, MH BALLASTS. 277 1000 METAL HALIDE HIGH BAY FLOOD LIGHTS <br /> ------- CONDUIT RUN CONCEALED IN WALLS, ABOVE W=4TH FLOOR X=5TH FLOOR CAB CABINET SIM SIMILAR STERNER BALLAST ASSEMBLY <br /> CEILING, IN FLOOR SLAB OR UNDERGROUND T=TRUSS LEVEL CAT CATALOG SPDT SINGLE POLE DOUBLE THROW <br /> SOURCE OF POWER - VAULT NOCLASS 1 DIVISION 1 EXPLOSION PROOF LUMINAIRE FOR HAZARDOUS AREA. 277 70 KILLARK HPS SCALE ROOMS CEILING MOUNTED <br /> -E- EMERGENCY CIRCUIT . CB CIRCUIT BREAKER SPST SINGLE POLE SINGLE THROW D <br /> - 48OV, 30, 3 WIRE CLG CEILING SPEC SPECIFICATION 25070 <br /> VOLTAGE ® 4 PANEL <br /> -FA- FIRE ALARM CIRCUIT 3 PANEL - 480Y/277V, 30, 4 WIRE CTR CENTER ST SHUNT TRIP 4 FT. INDUSTRIAL FLUORESCENT FIXTURE WITH 10% UPLIGHT, 277 (2) 32 DAY-BRITE (2) T8 TRUSS AREA CEILING MOUNTED <br /> 0 2 PANEL - 208Y 12OV, 30, 4 WIRE CHI CHILLED WATER RETURN SUSP SUSPEND <br /> -PA- PAGING CONDUIT WITH WIRE AS NOTED / CHI CHILLED WATER SUPPLY SW SWITCH PORCELAIN REFLECTOR, ELECTRONIC BALLAST AND WIRE GUARD. F232-PR-1 2EB-277-FL-173 <br /> "X" INDICATES EMERGENCY PANEL CKT CIRCUIT SYS SYSTEM <br /> -c- COPPER GROUND WIRE, SIZE AS NOTED "I" INDICATES ISOLATED POWER AND GROUND PANEL COAX COAXIAL TEL TELEPHONE 4 FT. WALL MOUNTED FLUORESCENT FIXTURE 277 (2) 32 DAY-BRITE <br /> F (2) T8 CRANE SICK BAY WALL MOUNTED <br /> -Lv- LOW VOLTAGE CONDUIT/WIRE COL COLUMN T'STAT THERMOSTAT ELECTRONIC BALLAST. WB232 CP-1/2EB-277 <br /> CONDUIT TURNED UP RECEPTACLES C CONDUIT XFMR TRANSFORMER <br /> C.O. CONDUIT ONLY TYP TYPICAL ' ' 277 1000 KIRLIN METAL HALIDE HIGH BAY RECESSED <br /> CONDUIT TURNED DOWN 30 SINGLE, WITH 30A, 48OV, 3?, 4 POLE, WITH CONT CONTINUE UH UNIT HEATER G DIRECTIONAL RECESSED LUMINAIRE <br /> CUSTOM BUILT 2x 2 <br /> 9 BACK BOX, GROUND THRU EXTRA POLE AND SHELL. CU COPPER UG UNDRGROUND STERNER BALLAST ASSEMBLY <br /> r1I1f FLEXIBLE CONDUIT, 1/2" UNO CT CURRENT TRANSFORMER U.O.N. UNLESS OTHERWISE NOTED QUARTZ FLOOD LIGHT. ONE PIECE DIE-CAST ALUMINUM HOUSING WITH DAY-BRITE <br /> DROUND20A,120V,1?,2P,3W, PARALLEL BLADE DC DIRECT CURRENT VAV VARIABLE AIR VOLUME 120 500 QUARTZ HIGH BAY EMERGENCY <br /> - CONDUIT TO BE REMOVED GROUNDED DED DEDICATED CIRCUIT VERT VERTICAL H SIDE HINGES,TEMEPERED GLASS. QF-500-LP-120 FLOOD LIGHTS <br /> FOURPLEX-2 DUPLEX, 20A,10,2P,3W DEG DEGREE D WP WEATHERPROOF 2'x4' FLUORESCENT GRID TROFFER. LIGHT FIXTURES TO HAVE #12 PATTERN 277 2 32 LITHONIA <br /> EQUIPMENT TO BE REMOVED EG. PANELBOARD PARALLEL BLADE GROUNDED. DET DETAIL WH WATER HEATER J ( ) (2) T8 HALLWAY RECESSED <br /> ( ) ACRYLIC DIFFUSERS, 0.125" THICK. ENERGY SAVING ELECTRONIC BALLAST 2GT-232-A12125-277-GEB-GMF 3500'K <br /> WP WEATHERPROOF DUPLEX RECEPTACLE, 15A, 120V, 10, DIAM DIAMETER W WATT <br /> DISTRIBUTION 2P, 3W PARALLEL BLADE, GROUNDED FA FIRE ALARM W%0 WITH ITH OUT X DIE CAST ALUMINUM EXIT FIXTURES, DUAL VOLTAGE INPUT 120/277 VAC, 60'. 277 8.7W SURELITES LED HALLWAY SURFACE MOUNT <br /> cFI GROUND FAULT INTERRUPTER TYPE DUPLEX RECEPTACLE <br /> FACP FIRE ALARM CONTROL PANEL FOOT RED LETTERS ON WHITE HOUSING FINISH. LED LAMPS. CAX - 7 1 70 00 - R W <br /> ® PANELBOARD, 480V, 34�, 3W, PANELBOARD � 20A, 120V, 14, 2P, 3W PARALLEL BLADE, GROUNDED FATC FIRE ALARM TERMINAL CABINET FURN FURNISH I� KIM WM2-CUSTOM SLIPFlTTER MOUNT, METAL HALIDE FIXTURE, TO COME 277 1000 KIM#AFL31/1000SMH277/LG- METAL LOW BAY MOUNT TO CENTER <br /> PANELBOARD, 480Y/277V, 30, 4W, PANELBOARD, GEN GENERATOR K COMPLETE WITH 3C, 12 AWG 10 FT. SIEMENS 5DH3-511 CORD, SAFETY CHAIN LESS BALLAST, GREY HALIDE OF I-BEAM <br /> INFO INFORMATION GRN GREEN <br /> PANELBOARD, 208Y/12OV, 30, 4W, PANELBOARD 4FT. FLOURESCENT OPEN "STRIP" PRUDENTIAL# <br /> AUXILIARY SYSTEMS JB JUNCTION BOX GND GROUND FIXTURE WITH BAKED ENAMEL FINISH 277 28 P-T5-WG-04'-BWE-277 28W JANITOR SURFACE <br /> KW KILOWATT HTR HEATER <br /> Mcc MOTOR CONTROL CENTER 010 P.A..=SYSTEM T ARAYNNUATOR, WALL MOUNTED AND WITH WIRE GUARD T5 CLOSET <br /> �G1) KWH KILOWATT HOUR HGT HEIGHT <br /> O 400Hz PANEL KV aQ P.A. SYSTEM SINGLE HORN LGTH LENGTH HID HIGH HZ HERTZ NTENSITY DISCHARGE TEMPEREDAGLASSNFRESNELOLENS. SELFNT CLEAR FLAN ED TRIM ALUMINUM <br /> RNG.REFLECTOR <br /> ELECTRONIC 277 (18 PORTFOLIO <br /> 4081LI4G TRW RESTROOMS PENDANT <br /> o SPECIAL PANEL AS NOTED ) LT LIGHT HPS HIGH PRESSURE SODIUM M PROGRAM START BALLAST. UL LISTED WET LOCATION. <br /> } P.A. SYSTEM TWO(2) HORN CLUSTER LG LONG HV HIGH VOLTAGE 4' LINEAR LOW PROFILE WALL MOUNT FLUORESCENT (1) LAMP FIXTURE, PRUDENTIAL # <br /> EQUIPMENT DEVICES MAG MAGNETIC HORIZ HORIZONTAL STEEL CONSTRUCTION, ALUMINUM END PLATES, WHITE EXTRUDED ACRYLIC 277 1 T5W RESTROOMS WALL <br /> / S1-1T5-04-YGW-277- <br /> P.A. SYSTEM THREE(3) HORN CLUSTER MAINT MAINTENANCE HP HORSEPOWER N <br /> $ SINGLE POLE TOGGLE SWITCH WRAP AROUND LENS. WHITE FINISH. UL LISTED DAMP LOCATION. SUR-10THD <br /> MFG MANUFACTURER IG ISOLATED GROUND <br /> P.A. SYSTEM FOUR(4) HORN CLUSTER MAX MAXIMUM EA EACH I SAME AS TYPE N EXCEPT PENDANT HUNG 1 PRUDENTIAL # 28W <br /> $3 THREE-WAY TOGGLE SWITCH MECH MECHANICAL EL ELEVATION N- I 277 �� S1-iT5-04-YGW-277- T5 RESTROOMS PENDANT <br /> SPEAKER, RECESSED MOUNTED IN CEILING MEZZ MEZZANINE ELECT ELECTRIC CA48-IOTHD <br /> 1771 PUSHBUTTON STATION MIN MINIMUM EMT ELECTRICAL METALLIC TUBING SAME AS TYPE N-1 EXCEPT 8' IN LENGTH ( PRUDENTIAL <br /> MAGNETIC DOOR RELEASE MISC MISCELLANEOUS EMER EMERGENCY N-2 277 22� S1-1T5-08-YGW-277- 28W RESTROOMS PENDANT <br /> ® MANUAL MOTOR STARTER MTD MOUNTED ENGR ENGINEER CA48-10THD T5 <br /> ® MAGNETIC MOTOR STARTER ® TELEPHONE CABINET MTG MOUNTING EQUIP EQUIPMENT HIGH EFFICIENCY BASKET TYPE FIXTURE. 20 GA. STEEL CONSTRUCTION FOCAL POINT # <br /> LIGHTING NEC NATIONAL ELECTRIC CODE ETC ETCETERA MATTE WHITE ANITMICROBIAL POWDER COAT FINISH. FROSTED ACRYLIC DIFFUSER 277 �4) FAR22AC2T5S277G1WHA T4W BREAK ROOM RECESSED <br /> a COMBINATION STARTER, CIRCUIT BREAKER TYPE, NC NORMALLY CLOSED EWC ELECTRIC WATER COOLER O WITH MICRO PRISM PATTERN. PROGRAM START BALLAST. UL LISTED. <br /> 30A UNLESS NOTED OTHERWISE FIXTURE TYPE DESIGNATION. SEE FIXTURE SCHEDULE, NIC NOT IN CONTRACT EXIST EXISTING <br /> A 12"ADJUSTABLE COVE LIGHT. 120V WIRING WITH INTEGRAL COLOR KINETICS # <br /> gi DWG. FEOb. QUANTITY AND RATING OF LAMPS NO NORMALLY OPEN EXTR EXTERIOR 120 4.5 LED RESTROOMS <br /> ENCLOSED CIRCUIT BREAKER SIZE AS NOTED -3a POWER SUPPLY. MOUNTING TRACK FOR INSTALLATION. 4200K 12"-#523-000004-03 WALL <br /> ON DRAWING (A=TYPE, 2=QUANTITY, 34=LAMP RATING) NTS NOT TO SCALE EXP EXPLOSION PROOF <br /> No. OR # NUMBER FOR FEEDER <br /> Ey DISCONNECT SWITCH, FUSED, 30=SWITCH RATING, HIGH INTENSITY DISCHARGE FIXTURE, TYPE AS NOTEDOC ON CENTER LED SAME AS TYPE P EXCEPT 6" LONG COLOR KINETICS # RESTROOMS <br /> 20=FUSE RATING FIXT FIXTURE 120 <br /> INCANDESCENT OR COMPACT FLUORESCENT FIXTURE OD OUTSIDE DIAMETER FLEX FLEXIBLE P-1 2.2 6'-#523-000005-03 WALL <br /> ON EMERGENCY SYSTEM, TYPE AS NOTED PNL PANEL FLR FLOOR <br /> LKCO <br /> DISCONNECT SWITCH, NON-FUSED, 30A % PERCENT 4' SMALL PROFILE UNDERCABINET LIGHT. EXTRUDED ALUMINUM CONSTRUCTION. (1) A # 2gW <br /> UNLESS NOTED OTHERWISE F®f EXIT LIGHTING SIGN, WALL MOUNTED. PERP PERPENDICULAR Q WHITE POWDER COAT ANTIMICROBIAL FINISH. UL LISTED. 277 28W L2F4-277-SWH T5 BREAK ROOM SURFACE <br /> MO MOTOR CONTROLLER EXIT LIGHTING SIGN, SUSPENDED OR CEILING 4 OR PH PHASE <br /> ® MOUNTED. DIRECTION OF EGRESS AS NOTED FVC POLYVINYL CHLORIDE 21" SOLATUBE DAYLIGHT SYSTEM. UV AND IMPACT RESISTANT ACRYLIC OUTER SOLATUBE# NA <br /> Ill TRANSFORMER, SIZE AND TYPE AS NOTED PWR POWER R AND INNER DOME WITH 92% LIGHT TRANSMISSION. SPECULAR ALUMINUM TUBE. NA NA S750DS-DA-DAT-F11-E02-L1-I LOCKER ROOM SURFACE <br /> ® 1'x4' (1) LAMP FIXTURE PF POWER FACTOR SELF MOUNTED FLASHING. OPTIVIEW DIFFUSER. UL LISTED. <br /> 4 MOTOR, 120V,1?, SIZE AS NOTED ® LIGHT ON EMERGENCY CIRCUIT DPDT DOUBLE POLE DOUBLE THROW <br /> MOTOR, 208V, 3?, SIZE AS NOTED a LED COVE LIGHT. DNST DOWNLE POLE SINGLE THROW <br /> MOTOR, 46OV, 3?, SIZE AS NOTED $ SWITCH DWG DRAWING <br /> ® JUNCTION BOX, FIELD SIZED OR AS NOTED $� OCCUPANCY SENSOR SWITCH <br /> GROUNDING PIGTAIL ® OCCUPANCY SENSOR <br /> Ca ® PHOTOCELL <br /> ® PULLBOX, FIELD SIZED OR AS NOTED <br /> FIXTURE CALLOUT <br /> JB JUNCTION BOX, SPECIAL. FIELD SIZED OR AS NOTED X X DENOTES TYPE - <br /> © GENERATOR ALTERNATING CURRENT Y 'Y' DENOTES FIXTURE WATTAGE D <br /> (VOLTAGE, kW, FREQUENCY AS NOTED) <br /> O GROUND ROD, SIZE AS SPECIFIED OR NOTED FIRE ALARM SYSTEM FIRE ALARM SYSTEM (CONI <br /> N TELEPHONE OUTLET, WALL MOUNTED 12"ARF OR AS NOT <br /> N TELEPHONE OUTLET MOUNTED IN RAISED FLOOR ELEVATOR ALARM BELL HIMTAMPERSWITCH (VALVE SWITCH) <br /> SUBSCRIPT X:XX = DEVICE ADDRESS <br /> 13 DATA OUTLET MOUNTED IN RAISED FLOOR (� FIRE ALARM HORN, WALL OR CEILING FATC FIRE ALARM TERMINAL CABINET <br /> O PUSHBUTTON STATION, TYPE AS NOTED ®� FIRE ALARM HORN/STROBE, WALL OR CEILING [FA_C_­Pl FIRE ALARM CONTROL PANEL <br /> ® CONTROL PANEL Os xm SMOKE DETECTOR, SUBSCRIPT X:XX = DEVICE ADDRESS IFEAT-11 BATTERY CABINET ` <br /> EXPLOSION PROOF SEAL FITTING 11,11, AN ANNUNCIATOR (FIRE ALARM) ` <br /> MANUAL STATION, SUBSCRIPT X:XX = DEVICE ADDRESS <br /> ® RELAY x:xx "WP" = WEATHERPROOF, "EP" = EXPLOSIONPROOF ® MISCELLANEOUS PANEL/EQUIPMENT, TYPE AS NOTED <br /> F INDICTES WALL MOUNTING D WATERFLOW SWITCH, SUBSCRIPT X:XX = DEVICE ADDRESS, <br /> ® xx <br /> SOLENOID VALVE kA "P" = PRESSURE TYPE, "PD" = PRESSURE TYPE W/DELAY <br /> H8 At <br /> EQUIPMENT CONNECTION Ps)W HI/LO AIR PRESSURE SWITCH <br /> SUBSCRIPT X:XX = DEVICE ADDRESS =00 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE DRAWN A SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ACCEPTABILITY AAs Ds.o4.95 INDEX SHEET G 04.14.21 <br /> _ RECORD DRAWING ISSUED TO OWNER AAS JRB 11.25.96 - RECORD DRAWING C1946 CASNE CEC 05.14.13 THIS DESIGN AND OR NECKED <br /> SPECIflCATION IS ROVED EWR 06.04.95 srlEEr <br /> AADDDIONAL LIGHTING J#969151 LF LBF 02.09.98 D EVERETT FIRE PANEL REPLACEMENT W2640474 SAZAN/ZO 12.04.19 BOE//VG® APPROVED BY DEPT' DATE EWR 06.04.95 TITLENAC MODIFICATION C OA <br /> 8 RESTROOM UPGRADE 45-01 576045-00 DLR GROUP J.BECK 12.28.08 E SHOP DRAWINGS AGOW/HG 04.10.20 cN cK C <br /> Pete Linamen JRB 06.04.95 BUILDING 45-001 JOB NO. COMP NO. <br /> - RESTROOM UPGRADE DRAWING CLEANUP DLR GROUP JH 17.20.09 F AS GUILTS AGOW/HG 08.21.20 ,�" ,n„ <br /> C FIRE MAIN RELOCATION C1946 CASNE CEC 10.22.12 G NAC MODIFICATION AGOW/HG 04.14.21 ELECTRICAL MASTER EVERETT, WA, _G 140 <br /> . 45-001-EOA <br />