Laserfiche WebLink
ICC <br /> ma>vALLral:Orr <br /> SERVICE <br /> 1CC-ES Evaluation Report ESR-4266 <br /> Issued December 2020 <br /> This report is subject to renewal December:2021. <br /> www.icc-es,or+ I (800)423.6 87 I ( 2)6 9W0 43 A Subsidiary of the International Code Councils <br /> DIVISION:03 00 00—CONCRETE 3.0 DESCRIPTiON <br /> Section:0316 00- Concrete Anchors 3;1 KB-7Z2: <br /> DIVISION:05 00 00—METALS KB-TZ2 anchors are torque-controlled, mechanical <br /> Section:05 05 19—Post-Installed Concrete Anchors expansion anchors. KB-TZ2 anchors consist of a stud <br /> (anchor body), wedge (expansion elements), nut, and <br /> REPORT HOLDER: washer. The anchor(carbon steel version)''is illustrated in <br /> Figure 1.The stud is manufactured from carbon steelorAlS! <br /> HILT!,INC. Type 304 or Type 316 stainless steel materials. Carbon <br /> steel KB-TZ2 anchors have a minimum 5 pm (0.0002 inch) <br /> EVALUATION SUBJECT: zinc-nickel plating. The expansion elements for the carbon <br /> steel KB-TZ2 anchors are fabricated from carbon steel.The <br /> HILT! KWIK BOLT TZ2 CARBON AND STAINLESS expansion elements for the stainless steel KB-TZ2 anchors <br /> STEEL ANCHORS IN CRACKED AND UNCRACKED are fabricated from stainless steel. The hex nut for carbon <br /> CONCRETE steel conforms to ASTM A563-04.Grade A.and the hex nut <br /> for stainless steel conforms to ASTM F594. <br /> 1.0 EVALUATION SCOPE The anchor body is comprised of a high-strength rod <br /> Compliance with the following codes: threaded at end and a tapered mandrel at the other end. <br /> el 2018,2015,and 2012 International Building Cerde'`=(IBC) The tapered mandrel is enclosed by a three-section <br /> expansion element.The expansion element movement is <br /> 2018, 2015, and 2012 International Residential-Codee restrained by the mandrel taper and by a collar.The anchor <br /> (IRC) is installed in a predrilled hole with a hammer.When torque <br /> For evaluation for compliance with the National Building is applied to the nut of the installed anchor.the mandrel is <br /> Code of Canadae(NBCC),see listing report ELC-4266 drawn into the expansion element,which is in turn expanded <br /> For evaluation for compliance with codes adopted by' the <br /> against the wall of the drilled hole. <br /> Los Angeles Department of Building and Safety (LADBS). 3.2 Concrete: <br /> see ESR-4266 LABC and LARC Supplement. Normal-weight and lightweight concrete must conforms to <br /> Property evaluated: Sections 1903 and 1905 of the IBC. <br /> Structural, 3.3 Steel Deck Panels: <br /> 2,0 USES Steel deck panels must be in accordance with the <br /> The Hilti Kwik Bolt TZ2 anchor (KB-TZ2) is used as configuration in Figure 5A, Figure 5B, and Figure 5C and <br /> anchorage to resist static, wind, and seismic (Seismic have a minimum base steel thickness of 0.035 inch <br /> Design Categories A through F)tension and shear loads in (0.899 mm, 20 gauge). Seel must comply with ASTM <br /> cracked and uncracked normal-weight concrete and A653/A653M SS Grade 55 and have a minimum yield <br /> lightweight concrete having a specified compressive strength of 55,000 psi(379 MPa). <br /> strength, fc, of 2,500 psi to 8,500 psi 4.0 DESIGN AND INSTALLATION <br /> (17,2 MPa to 58.6 MPa). <br /> 4.1 Strength Design: <br /> The lie-inch-. 3/s-inch-, 1/2-inch-, sfe-inch- and 3 A-inch <br /> diameter(6.4 mm,9.5 mm, 12.7 mm and 15.9 mm)carbon 4.1.1 General:Design strength of anchors complying with <br /> steel KB-TZ2 anchors may be installed in the soffit of the 2018 and 2015 IBC,as well as Section accordance <br /> of the <br /> cracked and uncracked normal-weight or sand-lightweight 2018 and 2015 ChapterRC must be determined in accordance with <br /> concrete over metal deck having a minimum specified ACI 318-14 17 and this report. <br /> compressive strength. Pc.of 3,000 psi(20.7 MPa). Design strength of anchors complying with the 2012 IBC <br /> The anchoring system complies with anchors as as well as Section R301.i.3 of the 2012 IRC. must be <br /> described in Section 1901.3 of the 2018 and 2015 IBC,and determined in accordance with ACl 318-11 Appendix D and <br /> Section 1909 of the 2012 IBC.The anchoring system is an this report. <br /> alternative to cast-in-place anchors described in Section Design parameters provided in Table 4,Table 5, Table 6 <br /> 1908 of the 2012 IBC.The anchors may also be used where and Table 7 of this report are based on the 2018 and 2015 <br /> an engineered design is submitted in accordance with IBC (ACI 318-14) and the 2012 IBC (ACi 318-11) unless <br /> Section R301.1.3 of the!RC. noted otherwise in Sections 4.1,1 through 4.1.12. The <br /> h'va1uottntt Reports ore not to he cot trued asrepresenturg aesthetscc or Ott other a nr thxte,nut t,pc etac,t is.,ddrersed.nor are the)rn he anetrem;1 ;\ <br /> an endorsement aline subject of the report or a r'c"on ntend(tttoo jer to any.There A ott o armtttj�'1 i r C`Evaluation Semi,.E.LC,.:,lpre$t or Invited.rt., pps \ : <br /> ju:darfi Or aka'enr t.er:a thd.s repot',,.r as to any prodaCt t-tt.re f b:the report <br /> Copyright Chi 2020 ICC Evaluation Service,LLC_ All rights reserved. Page 1 of 1$ <br />