My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2611 ROCKEFELLER AVE 2022 ROCKEFELLER SQUARE 2 Plans 2024-04-26
>
Address Records
>
ROCKEFELLER AVE
>
2611
>
ROCKEFELLER SQUARE 2
>
Plans
>
2611 ROCKEFELLER AVE 2022 ROCKEFELLER SQUARE 2 Plans 2024-04-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2024 9:18:43 AM
Creation date
4/24/2024 7:48:45 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2611
Tenant Name
ROCKEFELLER SQUARE 2
Permit
FA2205-007
Year
2022
Notes
INSTALL LOW VOLTAGE FIRE ALARM SYSTEM IN NEW (4) STORY BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MS-7S Single Action Station NYC-Plate <br /> The MS-7S single action pull station is used with The NYC-Plate provides the backplate for the manual <br /> conventional fire alarm control panels.It features a set pull station.(See Figure 1). <br /> of single pole contacts and wire leads for connection to <br /> an initiating circuit. <br /> MS-7SP Double Action Station <br /> The MS-7SP is a double action pull station similar to <br /> the MS-7 station.with the additional feature of C I R E <br /> including both English and Spanish instructions r <br /> molded into the unit. 0W,3 <br /> MS-7LR Dual-action Agent Release Station <br /> The MS-7LR is designed for use with the Gamewell-FCISti <br /> fire alarm control panels with releasing capabilities "~` <br /> and Flex Series releasing systems.It features a set of <br /> single pole contacts and screw terminals used to <br /> connect to an initiating circuit. <br /> MS-7LRA Agent Release Station with Abort <br /> Figure 1 NYC-Plate <br /> The MS-7LRA is designed for use with the Gamewell- <br /> FCI fire alarm control panels with releasing capabilities Ordering Information <br /> and Flex Series releasing systems where system abort MS-7:Double action station <br /> capabilities are required.It consists of the following: <br /> MS-7AF**:Velociti addressable double action station <br /> • An MS-7LR mounted on a plate with an abort switch <br /> MS-7ASF**:Velociti addressable single action station <br /> • LED indicators that signal system normal and <br /> MS-7S:Single action station,wire leads <br /> system activated status <br /> MS-7LOB Double Action Station(Listed for Outdoor MS-7SP:Double action station,English and Spanish <br /> instructions <br /> Applications) <br /> The MS-7L0B station must be mounted on a Model MS-7LR:Agent release station,dual action <br /> SB-I/0 backbox.In retrofit applications,the pull MS-7LRA:Agent release station with abort switch, <br /> station is UL Listed for use with the WP-10 backbox.It LED indicators,dual-action <br /> is intended for use with conventional control panels MS-7LOB:Double action station,outdoor use <br /> and has a set of single pole contacts and screw <br /> (Includes SB-I/O-Indoor/outdoor use backbox) <br /> terminals. <br /> SB-I/O:Indoor/outdoor use backbackbox • <br /> Mounting <br /> The MS-7 interior pull stations may be surface SB 10:Surface backbox <br /> mounted or semi-flush mounted on a standard BG12TR:Trim ring for semi-flush mount,plastic <br /> double-gang,or4-inch(10.2 cm)square electrical box. NY-PLATE:NYC backplate for manual pull station <br /> An optional trim ring(BG12TR)may also be used for <br /> semi-flush mounting. *"For use with the Gamewell-FCI analog addressable <br /> control panels only. <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.