My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2611 ROCKEFELLER AVE 2022 ROCKEFELLER SQUARE 2 Plans 2024-04-26
>
Address Records
>
ROCKEFELLER AVE
>
2611
>
ROCKEFELLER SQUARE 2
>
Plans
>
2611 ROCKEFELLER AVE 2022 ROCKEFELLER SQUARE 2 Plans 2024-04-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2024 9:18:43 AM
Creation date
4/24/2024 7:48:45 AM
Metadata
Fields
Template:
Address Document
Street Name
ROCKEFELLER AVE
Street Number
2611
Tenant Name
ROCKEFELLER SQUARE 2
Permit
FA2205-007
Year
2022
Notes
INSTALL LOW VOLTAGE FIRE ALARM SYSTEM IN NEW (4) STORY BLDG
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SpectrAlert Advance Outdoor Strobe,and Horn Strobe Specifications <br /> Architect/Engineer Specifications <br /> General <br /> SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall <br /> be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. <br /> Also,SpectrAlert Advance products,when used with the Sync•Circuit'"Module accessory,shall be powered from a non-coded notification <br /> appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification <br /> appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between <br /> 16.5 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full- <br /> wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95, <br /> 110,115, 135. 150, 177,and 185. <br /> Strobe <br /> The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and shall be approved for fire protective service. <br /> The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for <br /> visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash <br /> tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved <br /> per UL.The strobe shall be suitable for use in wet environments. <br /> Horn Strobe Combination <br /> The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and UL 464 and shall be approved for <br /> fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with <br /> Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light <br /> shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch <br /> between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch.On four- <br /> wire products,the strobe shall be powered independently of the sounder.The horn strobe on a 2-wire model shall work on a non-coded power <br /> supply. The horn on 4-wire horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with <br /> its weatherproof back box in order to remain outdoor listed per UL. The horn strobe shall be suitable for use in wet environments. <br /> Physical/Electrical Specifications <br /> Operating Temperature -40°F to 151°F(-40°C to 66°C) <br /> Strobe Flash Rate 1 flash per second <br /> Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 • <br /> Operating Voltage Range2 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) <br /> Operating Voltage Range with MDL3 Sync Module 8.5 to 17.5V(12 V nominal)or 16.5 to 33V(24 V nominal) <br /> Input Terminal Wire Gauge 12 to 18 AWG <br /> Ceiling-Mount Dimensions(including lens) 6.8"diameter x 2.5"high(173 mm diameter x 64 mm high) <br /> Strobe/Horn Strobe Dimensions 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mrn W x 33 mm D) <br /> Strobe/Horn Strobe Dimensions with Back Box 5.6"L x 4.7"W x 1.3"D(142 mm L x 119 mm W x 33 mm D) <br /> Ceiling-Mount Weatherproof Back Box Dimensions 7.1"diameter x 2.0"high(180 mm diameter x 51 mm high) <br /> Notes: <br /> 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. <br /> 2.Products will operate at 12 V nominal only for 15 and 15/75 cd. <br /> AVCS11401 <br />
The URL can be used to link to this page
Your browser does not support the video tag.