L-Series Specifications <br /> Architect/Engineer Specifications <br /> General <br /> L-Series low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 1/2-inch back box,4-inch octagon back <br /> box,or double-gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/e-inch back box.A universal mounting plate <br /> shall be used for mounting products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series <br /> products,when used with the Sync•Circuit""Module accessory.shall be powered from a non-coded notification appliance circuit output <br /> and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,24-volt-rated notification appliance circuit outputs <br /> shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit(0°C to 49°C)from <br /> a regulated DC or full-wave rectified unfiltered power supply.Low Frequency Sounder strobes shall have field-selectable candela settings <br /> including 15,30,75,95,110, 135, 185.The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone <br /> and have a permanent marking on the housing that reads"low frequency sounder". <br /> Low Frequency Sounder <br /> The low frequency sounder shall be a System Sensor L-Series Model listed to UL 464 and shall be approved for fire protective <br /> service.The low frequency sounder and the Sync•Circuitr"MDL3 Module accessory,if used,shall be powered from a notification appliance <br /> circuit output and shall operate on a nominal 24 volts(includes fire alarm panels with built-in sync).When used with the Sync•Circuit Module <br /> MDL3,24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts.If the notification appliances are not UL <br /> 9th edition listed with the corresponding panel or power supply being used,then refer to the compatibility listing of the panel to determine <br /> maximum devices on a circuit.The low frequency sounder has an option to switch between temporal three or temporal four pattern,non- <br /> temporal(continuous)pattern and coded supply within the frequency range of 520Hz± 10%square wave tone.The low frequency sounder <br /> shall operate on a coded or non-coded power supply with high and low volume settings. <br /> Low Frequency Sounder Strobe Combination <br /> The low frequency sounder strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved <br /> for fire protective service.The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the <br /> Americans with Disabilities Act requirements for visible signaling appliances.flashing at 1 Hz over the strobe's entire operating voltage range. <br /> The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The sounder shall have an option to switch between a <br /> temporal three or temporal four pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The low <br /> frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply with high and low volume settings. <br /> The field selectable tones will sound within the frequency range of 520 Hz±10%square wave tone. <br /> Synchronization Module <br /> The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module <br /> shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three.Also,while operating the strobes,the module shall <br /> silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires.The module shall mount to a 411/1e x <br /> 4t7/16 x 21/8-inch back box.The module shall also control two Class B circuits or one Class A circuit.The module shall synchronize multiple <br /> zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate <br /> on a coded power supply. <br /> Physical/Electrical Specifications <br /> Standard Operating Temperature 32°F to 120°F(0°C to 49°C) <br /> Humidity Range 10 to 93%non-condensing <br /> Frequency Range 520 Hz±10% <br /> Strobe Flash Rate 1 flash per second <br /> Nominal Voltage Low Frequency Sounder Regulated 24 DC/FWR1 <br /> Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR1 <br /> Operating Voltage Range 16 to 33 V(24 V nominal) <br /> Operating Voltage Range MDL3 Sync Module 16.5 to 33 V(24 V nominal) <br /> Input Terminal Wire Gauge 12 to 18 AWG <br /> Dimensions <br /> Wall Sounder Strobe(including lens) 5.6'L x 4.7'W x 1.9"D(142 mm L x 119 mm W x 49 mm D) <br /> Standard Wall Sounder 5.6°L x 4.7"W x 1.5'D(142 mm L x 119 mm W x 38 mm D) <br /> Compact Wall Sounder 5.25'L x 3.46'W x 1.5"D(133mm L x 88mm W x 38mm D) <br /> Ceiling Sounder 6.8°diameter x 1.4'high(173mm diameter x 36mm high) <br /> Standard Wall Sounder with SBBRUSBBWL Surface 5.7"L x 4.8"W x 3.3"D <br /> Mount Back Box (145 mm L x 120 mm W x 87 mm D) <br /> Compact Wall Sounder with SBBGRUSBBGWL Surface 5.4"L x 3.6"W x 3.0"D(137 mmL x 91mm W x 76 mm D) <br /> Mount Back BOX <br /> Low Frequency Ceiling Sounder with SBBCRUSBBCWL 6.9"diameter x 3.9'high(175mm diameter x 99mm high) <br /> Surface Mount Back Box <br /> Notes: <br /> 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. <br /> AVOS916-01•10/1/2019•Page 2 <br />