Laserfiche WebLink
• • <br /> tN <br /> Mr. Terri Willey <br /> NW Remodel and Deck, LLC <br /> Plan Check Number: B2109-057, First Building Review <br /> October 12, 2022 <br /> Miscellaneous: <br /> 7o/ <br /> The project includes replacing door and windows. Safety glazing should be specified where <br /> required. See IBC Section 2406.4. <br /> 1/The Kitchen may require the installation of a grease trap. These documents have not been <br /> reviewed for the treatment of oil or grease that may enter the City of Everett sewer system. <br /> Contact Industrial Pretreatment at (425)257-8240 regarding pretreatment or grease removal <br /> requirements. The drawings shall specify the requirement to install a grease trap if required. <br /> See Everett Municipal Code Chapter 14.42. <br /> e Kitchen indicates the presence of a hood and stove. The following comments should be <br /> 41Wddressed: <br /> a. Requirements for commercial kitchen hoods are governed by IMC Section 507. The <br /> expected hood installation (i.e., Type I or Type II) should be specified in the drawings. <br /> b. The type of cooking appliance (e.g., medium duty, heavy duty, etc.) should be clarified. <br /> The type shall be as indicated by the manufacturer's specifications on the appliance. <br /> c. The requirements for grease ducts for commercial kitchens hoods are provided in IMC <br /> Section 506. The requirements for the intended hood shall be specified in the drawings, <br /> /' including but not limited to clearances. The proposed path for the duct should be shown. <br /> 9.The bathrooms should specify non-absorbent floors and walls. See IBC Section 1209.2. <br /> X.The bathrooms include more than one water closet. The bathrooms should specify floor drains. <br /> See UPC-18 Section 418.3(1). <br /> / <br /> 7,,1�.The Laundry room requires a floor drain. See UPC-18 Section 418.3(2). <br /> Structural <br /> The structural drawings do not specify the construction of the deck and exterior stair <br /> diaphragms. Detail 6/S-4.0 states"decking by owner". The deck and exterior stairs are not <br /> laterally stable and require bracing. See IBC Sections 1603.1, 1604.1, 1604.4, and 1613.1, and <br /> ASCE 7-16 12.2.1. <br /> ,2° The proposed construction includes removing an interior wall west of the stairs and constructing <br /> a new shear wall using the south stair shaft wall. The new wall is required to comply with <br /> current code for tributary loading, including the portions south and west that are tributary to <br /> this wall. The connections to the diaphragms are not clear. It appears that drag framing may <br /> be required. Additional details should be included in the drawings. Calculations substantiating <br /> the load path should be submitted for review. See IBC Sections 1604.1, 1604.4, and 1613.1, <br /> and ASCE 7-16 Section 12.10.2. <br /> O3200 Cedar Street 0 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page4of5 <br />