Laserfiche WebLink
S- ;� Structural Design Associates <br /> ---' . Engineering Structures to Last <br /> tb`'!.tL a <br /> October 31, 2022 <br /> Subject: Building Official Comments, Plan Check Number: B2109-057 <br /> SDA Job # 9281A <br /> To whom this may concern: <br /> At the request of Terry Willey, this office reviewed the subject project to answer the <br /> building official comments. The following is the answer to those comments. <br /> Structural: <br /> 1) The deck is supported by wood shear walls at the building and cantilevered <br /> timber columns away from the building. The decking is not used as a <br /> diaphragm. The overstrength factor was not used in the original design, design <br /> has been revised to include overstrength. <br /> 2) Collector with connections have been added to the plans, drag strut calculations <br /> and connection design has been added to the calculations. <br /> Please contact me for any questions concerning this letter. <br /> Respectfully, <br /> COV: <br /> At'zorac"° OPrit,1 <br /> Chris Lalonde, EIT 0 <br /> 34383 <br /> NIA. <br /> N. <br /> '+, 202` <br /> '��• NOV 0 4 <br /> 3006 Rucker Avenue Everett, WA 98201 Ph: 425-339-0293 <br /> www.sdaeverett.com <br />