My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-04 2024-06-12
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-04
>
3003 W CASINO RD BLDG 45-04 2024-06-12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2024 11:24:17 AM
Creation date
4/24/2024 11:24:55 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-04
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURAL STEEL OBSERVATIONS REPORT MAYES I lrerracon <br /> Report Number: M7221502.0010 <br /> Service Date: 11/04/22 20225 Cedar Valley Rd Ste 110 <br /> Report Date: 11/08/22 Lynnwood,WA 98036-6365 <br /> 425-742-9360 <br /> Client Project <br /> The Boeing Company Boeing Everett 45-04 Paint Hangar Wing Stands <br /> Attn: Mark Gosnold 2451 100th St SW <br /> PO BOX 3707 Everett,WA <br /> Seattle, WA 98124-2207 <br /> Project Number: M7221502 <br /> Permit No.: Not Applicable <br /> GENERAL INFORMATION <br /> Mayes Terracon performed inspection of fit-up on the Air Damper support steel in Building 45-04 for the replacement of new <br /> ventilation dampers. <br /> Structural drawing M597 showed the basic layout pattern for the new damper support HSS steel sections. <br /> The damper structural frames were in the Upper Level fan rooms of Building 45-04. <br /> Inspection found the fit-up of the first course of two courses in compliance with the structural drawings. <br /> Inspection verified the WABO certification for UMC welder, Craig A Bailey, W07687 and verification of the approved weld <br /> procedure WPS.D11 FCAW-01. <br /> Inspection found the fit-up of these weld joints in compliance with the construction drawings and weld procedures. <br /> COMPLIANCE STATEMENT <br /> To the best of our knowledge, the items inspected today are in conformance with approved plans and specifications. <br /> Services: Special Inspections/Materials Testing <br /> Mayes/Terracon Rep.: Michael Virgilio <br /> Reported To: Skanska USA Building Inc <br /> Contractor: Skanska <br /> Report Distribution: <br /> See attached distribution list. <br /> Reviewed By: <br /> Barry Tuttle <br /> Project Field Manager <br /> The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client <br /> indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to <br /> the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. <br /> CT0001,10-16-13,Rev.10 Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.