Laserfiche WebLink
The CA-2 supports a DVC, paging microphone, optional FFT mum. Optional supervision is selected through program- <br /> telephone, and mounting location for an NCA-2 or NFS2- ming. Recommended wiring: 14 to 18 AWG (2.08 to 0.821 <br /> 3030D CPU.The ADDR audio door series can be used when mm2)twisted-pair. <br /> a CA-2 is mounted in the top two rows.The CA-1 supports a • Remote microphone interface(TB9): Recommended wir- <br /> DVC and an optional microphone in a single row. For firefight- ing: 14 to 18 AWG(2.08 to 0.821 mm2)twisted-pair. Power- <br /> ers' telephone applications with a CA-1, the CFFT1 can be limited. Maximum distance between remote microphone <br /> mounted in the row below the CA-1. and DVC: 1000 feet(300 m). <br /> NOTE:For NFS2-640/DVC applications using DAL devices, an • Push-to-talk interface (TB10): Dry contact. Recom- <br /> NCA-2 is required to annunciate DAL device events. mended wiring: 14 to 18 AWG(2.08 to 0.821 mm2)twisted- <br /> Refer to the DVC System Audio Product Application Guide pair. <br /> (part number M-AG-DVC) for more details on DVC applica- • Alarm bus TB12 : Power limited bysource. Recom <br /> tions). ( ) <br /> mended wiring: 14 to 18 AWG(2.08 to 0.821 mm2)twisted- <br /> Specifications pair. <br /> • FFT riser(TB13):Power-limited output.Class A(Style Z)or <br /> • 24 VDC power (TB1): 24 VDC, 1.0 A, non-resettable, Class B (Style Y) operation. Style Y two-wire connections <br /> power-limited by the source. Recommended wiring: 14 to require a 3.9K ohm, 1/2 watt resistor (P/N K-3.9K). Maxi- <br /> 18 AWG(2.08 to 0.821 mm2)twisted-pair. mum wiring resistance (including individual telephone zone <br /> • Digital audio ports, wire media, A and B (TB2, TB3): to last handset)permitted is 50 ohms, 10,000 feet(3048 m) <br /> Maximum distance per segment is 1900 feet(579.12 m)on maximum wiring distance at 12 AWG (3.31 mm2) to last <br /> Belden 5320UJ (18 AWG, TP) FPL cable: 18 AWG (0.821 handset. <br /> mm2)twisted-pair, foil-shielded, power-limited. Consult wir- • Optional DVC-AO analog audio output circuits (TB5, <br /> ing documentation provided in document P/N 52916ADD:C TB6, TB7, and TB8): Supervised, power-limited outputs. <br /> Addendum to DVC and DAA Manuals. Signal strength:+12 Vp-p nominal,+15 Vp-p maximum.Rec- <br /> • Digital audio ports, single- and multi-mode fiber-optic ommended wiring: 18 AWG (0.821 mm2)twisted-pair;max. <br /> media:(See notes below) 14 AWG(2.08 mm2).Maximum impedance:66 ohms. <br /> —DS-FM and DS-SFM fiber option module (no direct <br /> DAA connection): Standards and Codes <br /> • 6.5dB maximum attenuation for multi-mode with 50/125 The Digital Voice Command DVC and DVC-EM comply with <br /> micrometer cable @ 1310 nm. the following standards: <br /> • 10dB maximum attenuation for multi-mode with 62.5/ • NFPA 72 2002 National Fire Alarm Code. <br /> 125 micrometer cable @ 1310 nm. <br /> • 30dB maximum attenuation for single mode with 9/125 • Underwriters Laboratories Standards UL 864, 9th edition, <br /> and UL 2572. <br /> micrometer cable @ 1310 nm. <br /> —DS-SFM(single-mode fiber DAA connection): • Underwriters Laboratories of Canada (ULC) ULC-S527-99 <br /> Standard of Control Units for Fire Alarm Systems. <br /> • 17dB maximum attenuation for single-mode with 9/125 <br /> micrometer cable at 1310 nm going from the DS-SFM Listings and Approvals <br /> to the fiber DAA. <br /> • 4dB maximum attenuation for single-mode with 9/125 The listings and approvals below apply to the DVC and DVC <br /> micrometer cable going from the fiber DAA to the DS- EM Digital Voice Command. In some cases, certain modules <br /> SFM. may not be listed by certain approval agencies,or listing may <br /> • 12dB minimum attenuation going from the DS-SFM to <br /> be in process.Consult factory for latest listing status. <br /> the fiber DAA. • UL Listed:S635. <br /> —DS-RFM(multi-mode fiber DAA connection): • ULC Listed:S635. <br /> • Attenuation going from the fiber DAA to the DS-RFM: • FM Approved. <br /> • 2dB maximum attenuation for multi-mode with 50/125 • CSFM: 7165-0028:0224 (NFS2-3030); 7165-0028:0243 <br /> micrometer cable @ 850 nm for the DS-RFM. (NFS2-640). <br /> • 4dB maximum attenuation for multi-mode with 62/5/125 • FDNY: COA#6114 (NFS2-3030): COA#6085, COA#6121 <br /> micrometer cable @ 850 nm for the DS-RFM. (NFS2-640). <br /> • Attenuation going from the fiber DS-RFM to the fiber • City of Chicago approved: High Rise, Class 1, Class 2 <br /> DAA: (NFS2-3030,NFS2-640,NCA-2). <br /> • 12dB minimum*attenuation, 16dB for both cable types. • City of Denver approved(NFS2-3030). <br /> Notes: • PSB Corporation approved(Singapore)(NFS2-3030). <br /> 1. If the length of the fiber run results in an attenuation of <br /> less than 12dB,a suitable attenuator must be used. Product Line Information <br /> 2.ST®Style connection required at DAA end of any fiber DVC-EM: Digital Voice Command,digital audio processor with <br /> connection. LC style connectors are required for the DS message storage for up to 32 minutes of standard quality (4 <br /> FM,DS-RFM,and DS-SFM. minutes at high quality)`digital audio. Supports twisted-pair <br /> • Auxiliary input A(AUX A,TB4):Signal strength from low- wire media. Options:DS Fiber modules,DVC-RPU. <br /> level analog audio input:maximum 1.0 VRMS,or 1.41 Vp-p. DVC-RPU: Digital Voice Command Remote Paging Unit. <br /> Optional supervision is selectable through programming. Includes the keypad/display.Supports twisted-pair wire media; <br /> Recommended wiring: 18 AWG (0.821 mm2) twisted pair; use DS fiber modules for fiber media. See DN-60726. <br /> max. 14 AWG (2.08 mm2). Auxiliary input must be in the <br /> same room as the DVC. DVC-KD: Keypad for local annunciation and controls; status <br /> • Auxiliary input B (AUX B, TB14): Signal strength from LEDs and 24 user-programmable buttons. <br /> low-level analog audio input: 12 Vp-p nominal, 15 Vp-p maxi- <br /> — — �—e <br /> Page 2 of 4—DN-7045:1.12/20/2013 <br />