Laserfiche WebLink
20. Elevation difference in Gar& Mud Rm not shown on Detail 9 or Sheet A5.1: <br /> Architect to edit difference in A4.2 and A5.1 details. <br /> 21 . Specify max curb ht detail 1 D/A5. 1: Updated. <br /> 22. Show crawl space min 18':Jsts closer than 18"and Girders < 12"to be PT or natural <br /> resistant wood: 18" min crawl not added. Also Beams or girders < 12" frm ground will <br /> be specified PT. <br /> 23. Deferred statement(roof trusses) to be added to Structural general notes:Note to <br /> include in general structural notes..Engineer-of--record to review the deferred <br /> submittals and verify conformance with the construction documents per IBC. <br /> We have made revisions and updates in response to the extensive Structural comments <br /> dated July 29, 2021 . Thank you for noting some oversight and missing information <br /> which helps us avoid field errors and confusion. We believe the contractor is well <br /> versed in the code and licensed and competent to make reasonable decisions. If <br /> questions or clarity is needed we are available to facilitate resolving them. A <br /> reasonable perspective would conclude that not every code and reference would <br /> necessary be needed to be shown on the plans. We do not have space or time to <br /> rewrite all of the codes. However those regarding specific design decisions or depiction <br /> might warrant more detail as shown. <br /> Note: We are sending a complete updated beam report and also attached details that may be <br /> pertinent for clarity and detail. <br /> )/ o( 1 <br /> Submitted by3,1734 <br /> Dan Parrent, PE -�`;!<ft. <br /> (//L/ <br />