My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD 2021 BLDG 40-32 Plans 2024-05-02
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-32
>
Plans
>
3003 W CASINO RD 2021 BLDG 40-32 Plans 2024-05-02
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2024 9:21:54 AM
Creation date
5/2/2024 9:16:46 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-32
Permit
E2104-152
FA2104-006
Year
2021
Notes
REPLACE SPRINKLER MONITORING PANEL
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1-1:001 <br />122 <br />SV32-1 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1E266 <br />1-1:002 <br />123 <br />SV32-1 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1E266 <br />1-1:003 <br />124 <br />SV32-1 TAMPER <br />OS&Y Sprinkler Valve <br />TNEE266 <br />1-1:004 <br />125 <br />SV323 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1 E266 <br />1-1:005 <br />128 <br />SV32-3 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E266 <br />1-1:006 <br />127 <br />SV32-3 TAMPER <br />OS&Y Sprinkler Valve <br />TNE266 <br />1-1:007 <br />128 <br />SV32-5 WF PRESSURE <br />Waterflow, Pressure Switch with Delay <br />1E267 <br />11:008 <br />129 <br />SV32-5 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E267 <br />1-1:009 <br />12F <br />SV325 TAMPER <br />OS&Y Sprinkler Valve <br />TNE267 <br />1-1:010 <br />12B <br />SV32-7 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1 E267 <br />1-1:011 <br />12C <br />SV32-7 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E267 <br />1-1:012 <br />12D <br />SV32-7 TAMPER <br />OS&Y Sprinkler Valve <br />TNE267 <br />1-1:013 <br />12E <br />SV32-9 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1 E268 <br />1-1:014 <br />130 <br />SV32-9 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E268 <br />L1:015 <br />131 <br />SV32-9 TAMPER <br />OS&Y Sprinkler Valve <br />TNE268 <br />1-1:016 <br />132 <br />SV32-11 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1 E268 <br />1-1:017 <br />133 <br />SV32-11 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E268 <br />11:018 <br />134 <br />SV32-11 TAMPER <br />OS&Y Sprinkler Valve <br />TNE268 <br />1-1:019 <br />135 <br />SV32-13 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />t E268 <br />1-1:020 <br />136 <br />SV32-13 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E266 <br />1-1:021 <br />137 <br />SV32-13 TAMPER <br />OS&Y Sprinkler Valve <br />TNE268 <br />1-1:022 <br />138 <br />SV32-T1 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />TNE266 <br />1-1:023 <br />139 <br />SV32-T1 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />TNE266 <br />1-1:024 <br />13F <br />SV32-T1 TAMPER <br />OS&Y Sprinkler Valve <br />TNE266 <br />1-1:025 <br />13B <br />SV32-T3 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />TNE268 <br />1-1:026 <br />13C <br />SV32-T3 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />TNE268 <br />1-1:027 <br />13D <br />8V32-T3 TAMPER <br />OS&Y Sprinkler Valve <br />TNE268 <br />1-1:028 <br />13E <br />SV33-2 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1 E266 <br />1-1:029 <br />140 <br />SV33-2 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E266 <br />1-1:030 <br />141 <br />SV33-2 TAMPER <br />OS&Y Sprinkler Valve <br />TNE266 <br />1-1:031 <br />142 <br />SV33-4 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1E266 <br />1-1:032 <br />143 <br />SV33-4 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1E266 <br />1-1:033 <br />144 <br />SV33-4 TAMPER <br />OS&Y Sprinkler Valve <br />TNE266 <br />1-1:034 <br />145 <br />SV33-6 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1 E267 <br />L1:035 <br />146 <br />SV33-6 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E267 <br />1-1:036 <br />147 <br />SV33-6 TAMPER <br />OS&Y Sprinkler Valve <br />TNE267 <br />1-1:037 <br />148 <br />SV33-6 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1E267 <br />1-1:038 <br />149 <br />SV33-8 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E267 <br />1-1:039 <br />14F <br />SV33-6 TAMPER <br />OS&Y Sprinkler Valve <br />TNE267 <br />1-1:040 <br />14B <br />SV33-10 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1 E268 <br />1-1:041 <br />14C <br />SV33-10 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E268 <br />1-1:042 <br />14D <br />SV33.10 TAMPER <br />OS&Y Sprinkler Valve <br />TNE268 <br />1-1:043 <br />14E <br />SV33-12 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />1 E268 <br />1-1:044 <br />150 <br />SV33-12 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1 E268 <br />L1:045 <br />151 <br />SV33-12 TAMPER <br />OS&Y Sprinkler Valve <br />TNE268 <br />1-1:046 <br />152 <br />SV33-14 WF PRESSURE <br />Waterflow, Pressure Switch with Delay <br />1E268 <br />1-1:047 <br />153 <br />SV33-14 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />1E268 <br />1-1:048 <br />154 <br />SV33-14 TAMPER <br />OS&Y Sprinkler Valve <br />TNE268 <br />1-1:049 <br />155 <br />SV33-T2 WF PRESSURE <br />Waterflow, Pressure Switch with Delay <br />TNE266 <br />1-1:050 <br />156 <br />SV33-T2 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />TNE266 <br />1-1:051 <br />157 <br />SV33-T2 TAMPER <br />OS&Y Sprinkler Valve <br />TNE266 <br />11:052 <br />158 <br />SV33-T4 WF PRESSURE <br />Waterflow Pressure Switch with Delay <br />TNE267 <br />11:053 <br />159 <br />SV33-T4 WF ISO TAMPER <br />Waterflow Isolation Tamper Switch <br />TNE267 <br />1-1:054 <br />15F <br />SV33-T4 TAMPER <br />OS&Y Sprinkler Valve <br />TNE267 <br />1-1:055 <br />15B <br />SMK@FACP <br />E16.5-1E268 <br />1E268 <br />11:056 <br />15C <br />MAN PULL @ FACP <br />E16.5 - 1E268 <br />1E268 <br />1-1:057 <br />15D <br />ELEV 17 FA <br />E.5/13.75 - 1 E267 <br />1 E267 <br />1-1:058 <br />15E <br />ELEV 17 TRBL <br />E.5/13.75 - 1 E267 <br />1 E267 <br />1-1:059 <br />160 <br />ELEV 120-121 FA <br />G/15-40-033-1E262 <br />40-033-1E262 <br />1-1:060 <br />161 <br />ELEV 120-121 TRBL <br />G/1 5 - 40-033-1 E262 <br />40-033-1 E262 <br />1-1:061 <br />162 <br />MAIN VESDA FA <br />E/14-1E267 <br />1E267 <br />1-1:062 <br />163 <br />MAIN VESDA TRBL <br />E/14-1E267 <br />1E267 <br />1-1:063 <br />164 <br />GAYLORD PNL FA <br />F/14.5-1E267 <br />1E267 <br />1-1:064 <br />165 <br />GATLORD PNL TRBL <br />F/14.5 - 1 E267 <br />1 E267 <br />1-1:065 <br />166 <br />RADIO ROOM PNL FA <br />E/13.25 LEVA-4E267 <br />4E267 <br />1-1:066 <br />167 <br />1 RADIO ROOM PNL TRBL <br />E/13.25 LEVA -4E267 <br />4E267 <br />40-32 BUILDING FACP POINTS LIST M <br />SCALE: NONE EEC <br />REVISION BY I APPROVED#OAEVEREIT FIRE PANEL REPLACEMENT W2640474 SAZAN/JW SHOP DRAWINGS AGOW/HG <br />BY I APPROVED I DATE <br />LEGEND <br />FIRE ALARM ABBREVIATIONS SEE SHEET EO FOR SYMBOLS AND ABBREVIATIONS. <br />ALT <br />SECONDARY OR ALTERNATE ELEVATOR RECALL <br />BEAM DET <br />BEAM DETECTOR <br />CDR <br />COMPUTER/NETWORK/DATA/IDF ROOM <br />COL <br />COLUMN <br />COMM FAIL <br />COMMUNICATION FAILURE <br />CTRL <br />CONTROL <br />CW <br />CATWALK <br />DMPR <br />DAMPER <br />DD <br />DUCT SMOKE DETECTOR <br />DIESEL <br />DIESEL <br />FP <br />FIRE PUMP <br />ELEC <br />ELECTRICAL; ELECTRICAL ROOM <br />ELEV <br />ELEVATOR <br />EPP <br />EXCESS PRESSURE PUMP <br />GENERAL NOTES <br />FRCP <br />FIRE ALARM CONTROL PANEL <br />ELEV FF HAT LIGHT <br />FIRE FIGHTER HAT LIGHT IN A ELEVATOR <br />FLR <br />FLOOR <br />FM <br />FIRE MAIN VALVE <br />HEAT <br />HEAT DETECTOR <br />INTDEV <br />INTERFACE DEVICE, MONITORING OR CONTROL <br />ISO <br />ISOLATION VALVE <br />KITCHEN <br />KITCHEN <br />L BATT <br />LOW BATTERY <br />L FUEL <br />LOW FUEL (FIRE PUMP DIESEL TANK IS BELOW 50% FILLED) <br />LBY <br />LOBBY <br />LRD <br />LOW RATE DISCHARGE <br />MAN PULL <br />MANUAL PULL STATION <br />MECH <br />MECHANICAL ROOM <br />NAC <br />NOTIFICATION APPLIANCE CIRCUIT OR POWER SUPPLY <br />&Y <br />PD <br />OUTSIDEYOKEVAVLE <br />PUMP DI CHARGE VALVE <br />REFERENCE <br />REFERENCE DRAWINGS <br />PH <br />PENTHOUSE <br />PIV <br />POST INDICATOR VALVE <br />POWER FAIL <br />FACP POWER FAILURE <br />PREACT <br />PREACTION SYSTEM <br />PRI <br />PRIMARY <br />PS <br />PUMP SUPPLY VALVE <br />PWR <br />POWER <br />RF <br />ROOF <br />RLY <br />RELAY <br />SEC <br />SECTION VALVE <br />SHUNT <br />SHUNT TRIP <br />SMK <br />SMOKE DETECTOR <br />STL <br />STALL <br />STROBE <br />STROBE, HORN OR ANY NOTIFICATION DEVICE <br />SUPPR <br />SUPPRESSION <br />SUPV <br />SUPERVISORY <br />SV <br />SPRINKLER VALVE <br />CONSTRUCTION NOTES <br />TAMPER <br />TAMPER SWITCH <br />TL300 <br />TL300 TYCO COMMUNICATION DEVICE <br />TRBL <br />TROUBLE <br />UV <br />UNIT VALVE <br />VLV <br />VALVE <br />WF <br />WATERFLOW SWITCH <br />ZN <br />ZONE <br />ACCEPTABILITY <br />THIS DESIGN AND OR <br />SPECIFICATION IS AP ROVED <br />APPROVED BY I DEPT.T[ <br />FIRE ALARM SYSTEM DETAILS <br />MASTER <br />BUILDING 40-032 <br />IbIVN I 11"11L "' <br />A 11.13.20 <br />E506 <br />W2640474 COMP N0. <br />40-032-E506 <br />
The URL can be used to link to this page
Your browser does not support the video tag.