PLAN SYMBOLS <br />GROUNDING <br />POWER (CONT) <br />IL GHTING <br />SINGLE LINE <br />® <br />TELEPHONE/POWER POLE <br />REFER TO SHEETS E501 & E502 FOR DETAILED FIXTURE <br />-T-- <br />GROUND CABLE CONNECTION <br />TC <br />TIME CLOCK <br />SCHEDULE WITH SYMBOLS <br />-0- <br />GROUND ROD CONNECTION <br />© <br />CONTACTOR <br />HIGH INTENSITY DISCHARGE (HID) <br />POTENTIAL TRANSFORMER <br />�- <br />GROUND CABLE PIGTAIL <br />® <br />SAINO WALL SWITCH #32116 <br />FIXTURE <br />FLOODLIGHT - WALL MTD. / POLE MTD. <br />2 480:120 QUANTITY & RATIO <br />AS SHOWN <br />-G- <br />GROUND CABLE (UNDERGROUND) <br />POWER RECEPTACLES <br />® <br />CURRENT TRANSFORMER <br />LIGHTING FIXTURE - 2' x 4' LAYIN <br />800:5 <br />QUANTITY & RATIO <br />- G - <br />INSULATED GROUND BUS BAR <br />SEE SHEET E1B & E1C FOR DETAILED RECEPTACLE <br />FLUORESCENT WITH 3 TUBES <br />AS SHOWN <br />SCHEDULE <br />POWER <br />® <br />LIGHTING FIXTURE - 2' x 4' LAYIN <br />A AS <br />AMMETER w/SWITCH <br />MAE <br />PANELBOARD, 208Y/120V, 3 PHASE <br />(® INDICATES SHUNT -TRIP) <br />® <br />POWER OR TELEPHONE OUTLET MOUNTED <br />IN DOUBLE BOX ATTACHED TO UNDER- <br />® <br />FLUORESCENT WITH 4 TUBES <br />LIGHTING FIXTURE - 2' x 2' LAYIN <br />VOLTMETER w/SWITCH <br />® <br />PANELBOARD, 480Y/277V, 3 PHASE <br />SIDE OF RAISED FLOOR. TYPICAL OF <br />FLUORESCENT WITH 2 TUBES <br />© <br />PANELBOARD, 400 HZ, 200Y/115V <br />ALL OUTLET TYPES. REF. DETAILS 1 <br />AND 2, SHEET E538 <br />® <br />LIGHT FIXTURE - 1' x 4' SURFACE OR <br />HM <br />WATTHOUR METER <br />PENDANT FLUORESCENT WITH 2 TUBES <br />PANELBOARD, 28 VDC <br />® <br />OUTLET MOUNTED IN BOX ATTACHED TO <br />C� <br />DC PANEL POWER SUPPLY, SIZE AS NOTED <br />UNDERSIDE OF RAISED FLOOR <br />TYPICAL FOR ALL OUTLET TYPES <br />LIGHTING FIXTURES WIRED IN MASTER/ <br />SLAVE BALLAST CONFIGURATION <br />2-LAMP BALLASTS <br />00 AF <br />OB <br />BUS DUCT <br />WITH BREAKER <br />REF. DETAIL 1, E534 FOR PANELS LOCATED <br />REF. DETAIL 4, SHEET E534 <br />FOR 2 3 FIXTURES) -LAMP <br />(3 <br />00 AT <br />IN RAISED FLOOR AREAS <br />OUTLET MOUNTED IN BOX ON SLAB <br />®® <br />EQUIPMENT IDENTIFICATION <br />TYPICAL FOR ALL OUTLET TEES <br />® OR m <br />LIGHT FIXTURE - FLUORESCENT WITH <br />ALL BALLASTS ON EMERGENCY CIRCUIT <br />Y <br />"X" DENOTES EQUIPMENT NUMBER <br />REF. DETAIL 3, SHEET E534 <br />OR BATTERY PACK. <br />480V OR 480Y/277V <br />"Y" DENOTES HP, KVA OR KW RATING <br />1D10-1 <br />PANELBOARD <br />® <br />CIRCUIT BREAKER ENCLOSURE <br />COMMUNICATIONS <br />�� <br />LIGHT FIXTURE TAP 1/2" FLEXIBLE <br />METAL CONDUIT 4 TWO <br />600 <br />M. �.0. <br />(RATINGS AS <br />NOTED) <br />- #12: PHASE <br />3 3 W <br />Q' <br />CKT. BKR. ENCLOSURE WITH SHUNT <br />I <br />TELEPHONE OUTLET <br />CONDUCTORS, ONE NEUTRAL, ONE GROUND <br />-TRIP <br />PROVIDE 1/2" CONDUIT STUBBED <br />(3 #12 FOR SINGLE OR COMMON BALLAST <br />EY <br />DISCONNECT SWITCH (FUSED OR UNFUSED) <br />BELOW FLOOR OR ABOVE CEILING FOR <br />TWO TWISTED PAIR CAT. 3 CABLE <br />SWITCHING) <br />208V OR 208Y/120V <br />30/20 <br />SWITCH RATING/FUSE RATING <br />UNLESS INDICATED OTHERWISE. <br />INDIRECT LIGHTING FIXTURE <br />1D10-2 <br />225 A <br />PANELBOARD <br />(RATINGS AS <br />®' <br />MOTOR STARTER (COMBINATION) <br />i <br />DUPLEX TELEPHONE OUTLET <br />M. BKR. <br />NOTED) <br />® <br />MANUAL MOTOR STARTER <br />PROVIDE 1/2" CONDUIT STUBBED <br />BELOW FLOOR OR ABOVE CEILING <br />1_0 <br />EXIT SIGN, WALL MOUNTED <br />3PH, 4 W <br />M <br />TRANSFORMER (SIZE AS SHOWN, IN KVA <br />1W <br />WALL MOUNTED TELEPHONE OUTLET <br />PROVIDE 1/2" CONDUIT STUBBED <br />®� <br />EXIT SIGN, CEILING MOUNTED <br />�' <br />400 HZ AC <br />O <br />JUNCTION BOX <br />BELOW FLOOR OR ABOVE CEILING <br />MOUNT AT 60"AFF <br />FIXTURE IDENTIFICATION <br />"X" DENOTES FIXTURE TYPE <br />3C12-2 <br />150 A <br />PANELBOARD <br />(RATINGS AS <br />® <br />EQUIPMENT CONNECTION <br />1F <br />FLOOR MOUNTED TELEPHONE OUTLET <br />"Y" DENOTES TOTAL FIXTURE WATTAGE <br />M.BKR. <br />400 HZ <br />NOTED) <br />(LOCATION DIAGRAMMATIC) <br />© <br />FLUSH MOUNTED SIGNAL BELL <br />® <br />ON -OFF SELECTOR SWITCH ALLEN-BRADLEY <br />M14 K <br />DATA OUTLET, REF. DETAIL 5 <br />$ $a $* <br />TOGGLE SWITCHES -LINE VOLTAGE, <br />SINGLE POLE/ 3-WAY/ 4-WAY. NUMBER <br />+ _ <br />28 VDC <br />80OT-1ZT FLUSH BACK BOX W/ SOOT-R2TC <br />SELECTOR SWITCH W/ "ON -OFF" NAMEPLATE <br />E550, NUMBER INDICATES NUMBER OF <br />OF SWITCHES UNDER COMMON PLATE <br />2C4-1 <br />PANELBOARD <br />(RATINGS AS <br />CAT. 5 PAIR. F INDICATES 4-FIBER. <br />AS INDICATED <br />200 A <br />NOTE <br />❑� <br />MOMENTARY PUSH BUTTON STATION ALLEN- <br />OV <br />VOLUME CONTROL <br />$w 2$W 3$- <br />LOW -VOLTAGE LIGHTING CONTROL <br />M.BKR. <br />X <br />BRADLEYKBOX W/ <br />80OT KTG SERIES EMERGENCYPUSH- <br />® <br />SPEAKER, CEILING MOUNTED <br />SWITCHES. NUMBER SWITCHES UNDER <br />COMMON PLATE AS INDICATED <br />FILTER <br />RF FILTER (SIZE AS NOTED) <br />BUTTON W/ 80OT-N143 GAURD AND <br />REF. DETAIL A SHEET E570 <br />a,b,c <br />LOWER CASE LETTER INDICATES SWITCHING <br />"EMERGENCY EXHAUST" RED NAMEPLATE. <br />E]< <br />LOWBAY SPEAKER, <br />DUTY <br />COMBINATION STARTER <br />PUSHBUTTON STOP -START STATION <br />HORN TYPE <br />PROVIDE LOW -VOLTAGE SWITCH CONTROL <br />WIRING AS 3X #18 AWG IN 1/2" MIN. C <br />3A <br />CONTROLLER OR MCC <br />460 VOLT MOTOR (SIZE AS NOTED) <br />M <br />MID HEIGHT SPEAKER <br />HORN TYPE <br />FROM EACH LOW VOLTAGE SWITCH <br />TO THE LIGHTING CONTROL PANEL <br />T <br />CUBICLE NUMBER <br />4 <br />208 VOLT OR 240 V MOTOR <br />CLUSTER HORNS, REF. DETAILS <br />UNLESS OTHERWISE NOTED. <br />_ <br />(SIZE AS NOTED) <br />ON SHEET E571 <br />2$m $M <br />MOTION SENSOR SWITCH CONTROL <br />OR <br />115 VOLT MOTOR (SIZE AS NOTED) <br />FIRE ALARM <br />SYSTEM <br />REF. DETAIL 1A, SHEET E506 <br />FOR ASSEMBLY <br />® <br />POWER FACTOR CORRECTION CAPACITOR <br />F <br />ELEVATOR ALARM BELL <br />$m <br />LUTRON NTHF-40 HI-LUME FLUORESCENT <br />2 <br />LDC <br />400 HZ LINE DROP COMPENSATOR CABINET <br />9< <br />FIRE ALARM HORN/STROBE, WALL OR CEILING <br />DIMMING CONTROL AND BALLAST SYSTEM. <br />STARTER SIZE <br />W/O TRANSFORMER <br />/7\ <br />SMOKE DETECTOR, SUBSCRIPT X:XX = DEVICE ADDRESS, $w <br />REFERENCE DETAIL 2, SHEET E506. <br />XLDC <br />400 HZ LINE DROP COMPENSATOR WITH <br />"D" = DUCT SMOKE DETECTOR <br />INCANDESCENT DIMMER LUTRON <br />STEP DOWN TRANSFORMER <br />�x:xx <br />HEAT DETECTOR, SUBSCRIPT X:XX =DEVICE ADDRESS <br />NTLV 600 SERIES <br />POWER FACTOR <br />CORRECTION CAPACITOR <br />CONDUIT NOT BURIED <br />(INCLUDING ABOVE SUSPENDED <br />®x:xx <br />REMOTE RELAY, SUBSCRIPT X:XX = DEVICE ADDRESS <br />$� <br />INCANDESCENT DIMMMER, WATTAGE AS <br />CEILING & UNDER RAISED FLOOR) <br />�F xxx <br />MANUAL STATION, SUBSCRIPT X:XX = DEVICE ADDRESS <br />NOTED. LUTRON MODEL NUMBERS: <br />NT-1000 <br />HP <br />- MOTOR HORSEPOWER <br />BURIED CONDUIT WIRING <br />❑wF xz <br />WATERFLOW SWITCH, SUBSCRIPT X:XX = DEVICE ADDRESS, <br />NT-1500 <br />(UNDERGROUND & IN FLOOR SLAB) <br />ox <br />"P" = PRESSURE TYPE, "PD" = PRESSURE TYPE W/DELAY $uw <br />MAGNETIC LOW VOLTAGE DIMMER. <br />� <br />ELECTRICAL POWER <br />FLEXIBLE METAL CONDUIT <br />PS x:xx <br />HI/LO AIR PRESSURE SWITCH <br />LUTRON P/N NT-1003 <br />`` <br />FILTER <br />SUBSCRIPT X:XX = DEVICE ADDRESS <br />$us <br />MAGNETIC LOW VOLTAGE TOUCH SWITCH. <br />1 <br />CONDUIT HASH MARK DESIGNATIONS <br />�z:xx <br />TAMPER SWITCH (VALVE SWITCH) <br />LUTRON P/N NTETS-1 <br />CONDUCTOR <br />SUBSCRIPT X:XX = DEVICE ADDRESS <br />SINGLE LINE <br />FUSED SWITCH <br />_44��PHASE <br />NEUTRAL CONDUCTOR <br />GROUND CONDUCTOR <br />ISOLATED <br />FATC <br />FIRE ALARM TERMINAL CABINET <br />GREEN GROUND CONDUCTOR <br />FFA-C-Pl <br />FIRE ALARM CONTROL PANEL <br />o ulu <br />TRANSFORMER (DASHED LINE <br />DISCONNECT SWITCH <br />CIRCUIT SOURCE <br />l <br />INDICATES ELECTROSTATIC <br />SHIELD) <br />Y <br />P <br />-� <br />PANEL/CIRCUIT BREAKER NO.(S) <br />® <br />GENERATOR <br />1D6-1/1,3,5 <br />SURGE ARRESTER <br />O <br />CONDUIT TURNS DOWN <br />TRANSFER SWITCH <br />- 0 <br />CONDUIT TURNS UP <br />CIRCUIT BREAKER W/ <br />ELECTRICAL OPERATOR <br />[3-1 <br />DISCONNECT SWITCH <br />CONDUIT ONLY <br />E <br />LT = LONG T.D. TRIP UNIT <br />/ <br />ST = SHORT _ INSTANT. T RIPRIP NIT <br />UNIT <br />INTERLOCK <br />-E- <br />EMERGENCY CIRCUIT <br />LT <br />Y ❑ <br />GF = GND. FAULT TRIP UNIT <br />M=MECHANICAL <br />E=ELECTRICAL <br />DIAGRAM SYMBOLS <br />SCHEMATIC <br />SCHEMATIC <br />DISCONNECT SWITCH FLOW SWITCH - N.C. <br />OPENS ON INCREASE IN FLOW <br />�- <br />FUSE <br />a- FLOW SWITCH - N.O. <br />- - <br />CIRCUIT BREAKER CLOSES ON INCREASE IN FLOW <br />L,j <br />TRANSFORMER TEMPERATURE SWITCH - N.C. <br />OPENS ON RISING TEMP <br />GROUND CONNECTION °- TEMPERATURE SWITCH - N.O. <br />CLOSES ON RISING TEMP <br />PILOT LIGHT <br />* INDICATES COLOR LIMIT SWITCH - N.C. <br />PUSHBUTTON o-- LIMIT SWITCH - N.O. <br />__o o- <br />MOMENTARY CONTACT <br />NORMALLY OPEN RELAYS & COILS <br />PUSHBUTTON *=TYPE <br />MOMENTARY CONTACT M=MOTOR STARTER <br />NORMALLY CLOSED CR=CONTROL RELAY <br />C=CONTACTOR <br />OFFS ON <br />SELECTOR SWITCH R=TIME DELAY OR TIMING <br />l" <br />MAINTAINED CONTACT RELAY <br />TWO POSITION - I kp__ N.O. CONTACT <br />2 <br />i <br />-- N.C. CONTACT <br />SELECTOR SWITCH <br />- + - 2 <br />MAINTAINED CONTACT <br />THREE POSITION N.O. - ON DELAY CONTACT <br />3 <br />N.C. - ON DELAY CONTACT <br />SOLENOID VALVE <br />N.O. - OFF DELAY CONTACT <br />PRESSURE SWITCH + <br />- N.C. <br />OPENS ON RISING PRESSURE <br />� N.C. -OFF DELAY CONTACT <br />PRESSURE SWITCH - N.O. <br />CLOSES ON RISING PRESSURE <br />FLOAT OR LEVEL SWITCH - N.C. <br />OPENS ON RISING LEVEL <br />FLOAT OR LEVEL SWITCH - N.O. <br />CLOSES ON RISING LEVEL <br />PANEL NOMENCLATURE <br />XE 3 VO <br />-1 U D12-1-D <br />SUFFIX "-D" INDICATES DISTRIBUTION PANEL <br />[�__SUFFIX <br />"-1, -2, -3, ETC." IS USED TO INDICATE MULTIPLE <br />PANELS AT SAME LOCATION WHICH ARE SAME VOLTAGE, FED <br />FROM SAME VAULT AND LOCATED ON SAME FLOOR <br />NOTE: IF SUFFIX "-A, -B, -C, ETC." IS BEING USED <br />INSTEAD- OF "-1, -2, -3, ETC.", THEN CONTINUE USING <br />SUFFIX LETTERS FOR CLARITY <br />PANEL LOCATION AT NEAREST COLUMN <br />LOCATION OF PANEL WHEN NOT ON FIRST FLOOR: <br />M = MEZZANINE U = 2ND FLOOR <br />P = PENTHOUSE UT = UTIUDOR <br />R = Pt PARKING FLOOR V = 3RD FLOOR <br />S = P2 PARKING FLOOR W = 4TH FLOOR <br />T = TRUSS LEVEL X = 5TH FLOOR <br />TN = TUNNEL <br />SOURCE OF POWER: VAULT NO. <br />FLIGHTLINE EXAMPLE: VS38 FOR SUBSTATION S38 <br />VOLTAGE AND ASSOCIATED PANEL SYMBOL: <br />® 4 = 48OV, 3PH, 3W <br />® 3 = 480Y/277V, 3PH, 4W <br />v 2 = 208Y/12OV, 3PH, 4W OR 120/24OV, 1PH, 3W <br />© 5 = 400 HZ, 575Y/331V, 3PH, 4W <br />© 2 = 400 HZ, 200Y/115V, 3PH, 4W <br />W-1 I = 28 VDC <br />PREFIX: (BLANK) = NORMAL POWER PANEL <br />"I" = ISOLATED GND PANEL <br />"Z" = 400 HZ PANEL <br />"XE" = EMERGENCY PANEL <br />"XL" = LEGALLY REQUIRED STANDBY PANEL <br />"XS" = OPTIONAL STANDBY PANEL <br />GENERAL NOTES <br />1. CONDUIT: 1/2" MINIMUM - TYPE AND SIZE IN ACCORDANCE <br />WITH PLAN DRAWINGS AND THE SPECIFICATIONS. <br />2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER,INSULATION <br />TYPE THHN/THWN, UNLESS OTHERWISE NOTED. <br />3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO <br />NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR <br />TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY <br />INSULATED GROUND CONDUCTORS PER NEC 250-57(b) <br />EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS <br />FOLLOWS: <br />208Y 1 OV 480Y/277V <br />A 0 �LCEEFN7TERJSBUS <br />BIN PNL) BLACK BROWN <br />B 0 IN PNL) RED ORANGE <br />C 0 RIGHT BUS IN PNL) BLUE YELLOW <br />NEUTRAL WHITE GRAY <br />EQUIPMENT GROUND GREEN GREEN <br />ISOLATED GROUND GRN/YEL* GRN/YEL* <br />*GREEN WITH YELLOW TRACER <br />4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH <br />WITH CIRCUIT IDENTIFICATION AS SCHEDULED ON SHEETS E1B <br />& E1C, USING TYPED SCHEDULED ON SHEETS E1B & E1C, <br />USING TYPED LABEL. <br />5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION <br />OF JOB. <br />6. PANELS ARE TO BE IDENTIFIED BY LAMINATED PHENOLIC <br />NAMEPLATES AS DETAILED ON SHEET E1B AND AS SHOWN IN <br />THE SPECIFICATIONS. <br />ABBREVIATIONS <br />AFF <br />ABOVE FINISHED FLOOR <br />AHC <br />ABOVE HUNG CEILING <br />AL <br />ALUMINUM <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />AWG <br />AMERICAN WIRE GAUGE <br />CB <br />CIRCUIT BREAKER <br />C.O, CO <br />CONDUIT ONLY <br />CRU <br />COMPUTER ROOM UNIT <br />DED <br />DEDICATED <br />DP <br />DISTRIBUTION PANEL BOARD <br />EF <br />EXHAUST FAN <br />EMCS <br />ENERGY MANAGEMENT CONTROL SYSTEM <br />EMT <br />ELECTRICAL METALLIC TUBING <br />EPO <br />EMERGENCY POWER OFF <br />ES <br />EPO SWITCH <br />FACP <br />FIRE ALARM CONTROL PANEL <br />FAR <br />FIRE ALARM RELAY <br />FATC <br />FIRE ALARM TERMINAL CABINET <br />FDP <br />FIRE DETECTION PANEL <br />FVNR <br />FULL VOLTAGE, NON -REVERSING <br />GFI <br />GROUND FAULT INTERRUPTER <br />GND, G <br />GROUND <br />HP <br />HORSEPOWER <br />IMC <br />INTERMEDIATE METAL CONDUIT <br />LV <br />LOW VOLTAGE <br />M. BKR. <br />MAIN BREAKER <br />MCC <br />MOTOR CONTROL CENTER <br />MCM <br />MILLION CIRCULAR MILS <br />MLO <br />MAIN LUGS ONLY <br />NACB <br />NON -AUTOMATIC CIRCUIT BREAKER <br />NEC <br />NATIONAL ELECTRICAL CODE <br />N/A <br />NOT APPLICABLE <br />NC <br />NORMALLY CLOSED <br />NO <br />NORMALLY OPEN <br />PA <br />PAGING SYSTEM <br />PH <br />PHASE <br />PNL <br />PANEL <br />PVC <br />POLY -VINYL CHLORIDE (CONDUIT) <br />RF <br />RETURN FAN <br />RVNR <br />REDUCED VOLTAGE, NON -REVERSING <br />SRP <br />SMOKE REMOVAL PANEL <br />SWBD <br />SWITCHBOARD <br />SWGR <br />SWTTCHGEAR <br />SF <br />SUPPLY FAN <br />ST <br />SHUNT TRIP CIRCUIT BREAKER <br />01.13.15 <br />TO BE DETERMINED <br />T.D. <br />TIME DELAY <br />THHN <br />WIRE INSULATION TYPE REFER TO N.E.C. <br />THWN <br />WIRE INSULATION TYPE REFER TO N.E.C. <br />T/S <br />TWISTED AND SHIELDED PAIR <br />UH <br />UNIT HEATER <br />WP <br />WEATHER PROTECTED <br />XFMR <br />TRANSFORMER <br />_ AF <br />AMPS -FRAME <br />AT <br />AMPS -RIP <br />*NOTE: SEE SHEET <br />E506 FOR <br />ADDITIONAL FIRE ALARM 1 <br />ABBREVIATIONS. \ <br />/■ <br />REVISION <br />BY <br />I APPROVED <br />DATE <br />ISYM <br />REVISION <br />BY <br />I APPROVED <br />DATE <br />ACCEPTABILITY <br />DRAWN <br />DAlE <br />SUBTITLE <br />EVERETT FIRE PANEL REPLACEMENT W2640474 <br />SAZAN/JW <br />03.04.20 <br />THIS DESIGN AND/OR <br />ELECTRICAL LEGEND & ABBREVIATIONS <br />SHOP DRAWINGS <br />AGOW/HG <br />11.13.20 <br />�OE/A/G ® <br />m <br />SPECIFICATION IS <br />APPROVED <br />I <br />TITLE EVERETT FIRE PANEL REPLACEMENT <br />APPROVED BY <br />DE-1 <br />DATE <br />`G:�n"� <br />CHECKED <br />BUILDING 40-032 <br />i <br />APPROVED <br />ELECTRICAL MASTER EVERETT, WA. <br />MAN <br />GOW <br />DATE <br />A 11.13.20 <br />EO <br />W2640474 <br />40-032-EO <br />