PLAN SYMBOLS
<br />GROUNDING
<br />POWER (CONT)
<br />IL GHTING
<br />SINGLE LINE
<br />®
<br />TELEPHONE/POWER POLE
<br />REFER TO SHEETS E501 & E502 FOR DETAILED FIXTURE
<br />-T--
<br />GROUND CABLE CONNECTION
<br />TC
<br />TIME CLOCK
<br />SCHEDULE WITH SYMBOLS
<br />-0-
<br />GROUND ROD CONNECTION
<br />©
<br />CONTACTOR
<br />HIGH INTENSITY DISCHARGE (HID)
<br />POTENTIAL TRANSFORMER
<br />�-
<br />GROUND CABLE PIGTAIL
<br />®
<br />SAINO WALL SWITCH #32116
<br />FIXTURE
<br />FLOODLIGHT - WALL MTD. / POLE MTD.
<br />2 480:120 QUANTITY & RATIO
<br />AS SHOWN
<br />-G-
<br />GROUND CABLE (UNDERGROUND)
<br />POWER RECEPTACLES
<br />®
<br />CURRENT TRANSFORMER
<br />LIGHTING FIXTURE - 2' x 4' LAYIN
<br />800:5
<br />QUANTITY & RATIO
<br />- G -
<br />INSULATED GROUND BUS BAR
<br />SEE SHEET E1B & E1C FOR DETAILED RECEPTACLE
<br />FLUORESCENT WITH 3 TUBES
<br />AS SHOWN
<br />SCHEDULE
<br />POWER
<br />®
<br />LIGHTING FIXTURE - 2' x 4' LAYIN
<br />A AS
<br />AMMETER w/SWITCH
<br />MAE
<br />PANELBOARD, 208Y/120V, 3 PHASE
<br />(® INDICATES SHUNT -TRIP)
<br />®
<br />POWER OR TELEPHONE OUTLET MOUNTED
<br />IN DOUBLE BOX ATTACHED TO UNDER-
<br />®
<br />FLUORESCENT WITH 4 TUBES
<br />LIGHTING FIXTURE - 2' x 2' LAYIN
<br />VOLTMETER w/SWITCH
<br />®
<br />PANELBOARD, 480Y/277V, 3 PHASE
<br />SIDE OF RAISED FLOOR. TYPICAL OF
<br />FLUORESCENT WITH 2 TUBES
<br />©
<br />PANELBOARD, 400 HZ, 200Y/115V
<br />ALL OUTLET TYPES. REF. DETAILS 1
<br />AND 2, SHEET E538
<br />®
<br />LIGHT FIXTURE - 1' x 4' SURFACE OR
<br />HM
<br />WATTHOUR METER
<br />PENDANT FLUORESCENT WITH 2 TUBES
<br />PANELBOARD, 28 VDC
<br />®
<br />OUTLET MOUNTED IN BOX ATTACHED TO
<br />C�
<br />DC PANEL POWER SUPPLY, SIZE AS NOTED
<br />UNDERSIDE OF RAISED FLOOR
<br />TYPICAL FOR ALL OUTLET TYPES
<br />LIGHTING FIXTURES WIRED IN MASTER/
<br />SLAVE BALLAST CONFIGURATION
<br />2-LAMP BALLASTS
<br />00 AF
<br />OB
<br />BUS DUCT
<br />WITH BREAKER
<br />REF. DETAIL 1, E534 FOR PANELS LOCATED
<br />REF. DETAIL 4, SHEET E534
<br />FOR 2 3 FIXTURES) -LAMP
<br />(3
<br />00 AT
<br />IN RAISED FLOOR AREAS
<br />OUTLET MOUNTED IN BOX ON SLAB
<br />®®
<br />EQUIPMENT IDENTIFICATION
<br />TYPICAL FOR ALL OUTLET TEES
<br />® OR m
<br />LIGHT FIXTURE - FLUORESCENT WITH
<br />ALL BALLASTS ON EMERGENCY CIRCUIT
<br />Y
<br />"X" DENOTES EQUIPMENT NUMBER
<br />REF. DETAIL 3, SHEET E534
<br />OR BATTERY PACK.
<br />480V OR 480Y/277V
<br />"Y" DENOTES HP, KVA OR KW RATING
<br />1D10-1
<br />PANELBOARD
<br />®
<br />CIRCUIT BREAKER ENCLOSURE
<br />COMMUNICATIONS
<br />��
<br />LIGHT FIXTURE TAP 1/2" FLEXIBLE
<br />METAL CONDUIT 4 TWO
<br />600
<br />M. �.0.
<br />(RATINGS AS
<br />NOTED)
<br />- #12: PHASE
<br />3 3 W
<br />Q'
<br />CKT. BKR. ENCLOSURE WITH SHUNT
<br />I
<br />TELEPHONE OUTLET
<br />CONDUCTORS, ONE NEUTRAL, ONE GROUND
<br />-TRIP
<br />PROVIDE 1/2" CONDUIT STUBBED
<br />(3 #12 FOR SINGLE OR COMMON BALLAST
<br />EY
<br />DISCONNECT SWITCH (FUSED OR UNFUSED)
<br />BELOW FLOOR OR ABOVE CEILING FOR
<br />TWO TWISTED PAIR CAT. 3 CABLE
<br />SWITCHING)
<br />208V OR 208Y/120V
<br />30/20
<br />SWITCH RATING/FUSE RATING
<br />UNLESS INDICATED OTHERWISE.
<br />INDIRECT LIGHTING FIXTURE
<br />1D10-2
<br />225 A
<br />PANELBOARD
<br />(RATINGS AS
<br />®'
<br />MOTOR STARTER (COMBINATION)
<br />i
<br />DUPLEX TELEPHONE OUTLET
<br />M. BKR.
<br />NOTED)
<br />®
<br />MANUAL MOTOR STARTER
<br />PROVIDE 1/2" CONDUIT STUBBED
<br />BELOW FLOOR OR ABOVE CEILING
<br />1_0
<br />EXIT SIGN, WALL MOUNTED
<br />3PH, 4 W
<br />M
<br />TRANSFORMER (SIZE AS SHOWN, IN KVA
<br />1W
<br />WALL MOUNTED TELEPHONE OUTLET
<br />PROVIDE 1/2" CONDUIT STUBBED
<br />®�
<br />EXIT SIGN, CEILING MOUNTED
<br />�'
<br />400 HZ AC
<br />O
<br />JUNCTION BOX
<br />BELOW FLOOR OR ABOVE CEILING
<br />MOUNT AT 60"AFF
<br />FIXTURE IDENTIFICATION
<br />"X" DENOTES FIXTURE TYPE
<br />3C12-2
<br />150 A
<br />PANELBOARD
<br />(RATINGS AS
<br />®
<br />EQUIPMENT CONNECTION
<br />1F
<br />FLOOR MOUNTED TELEPHONE OUTLET
<br />"Y" DENOTES TOTAL FIXTURE WATTAGE
<br />M.BKR.
<br />400 HZ
<br />NOTED)
<br />(LOCATION DIAGRAMMATIC)
<br />©
<br />FLUSH MOUNTED SIGNAL BELL
<br />®
<br />ON -OFF SELECTOR SWITCH ALLEN-BRADLEY
<br />M14 K
<br />DATA OUTLET, REF. DETAIL 5
<br />$ $a $*
<br />TOGGLE SWITCHES -LINE VOLTAGE,
<br />SINGLE POLE/ 3-WAY/ 4-WAY. NUMBER
<br />+ _
<br />28 VDC
<br />80OT-1ZT FLUSH BACK BOX W/ SOOT-R2TC
<br />SELECTOR SWITCH W/ "ON -OFF" NAMEPLATE
<br />E550, NUMBER INDICATES NUMBER OF
<br />OF SWITCHES UNDER COMMON PLATE
<br />2C4-1
<br />PANELBOARD
<br />(RATINGS AS
<br />CAT. 5 PAIR. F INDICATES 4-FIBER.
<br />AS INDICATED
<br />200 A
<br />NOTE
<br />❑�
<br />MOMENTARY PUSH BUTTON STATION ALLEN-
<br />OV
<br />VOLUME CONTROL
<br />$w 2$W 3$-
<br />LOW -VOLTAGE LIGHTING CONTROL
<br />M.BKR.
<br />X
<br />BRADLEYKBOX W/
<br />80OT KTG SERIES EMERGENCYPUSH-
<br />®
<br />SPEAKER, CEILING MOUNTED
<br />SWITCHES. NUMBER SWITCHES UNDER
<br />COMMON PLATE AS INDICATED
<br />FILTER
<br />RF FILTER (SIZE AS NOTED)
<br />BUTTON W/ 80OT-N143 GAURD AND
<br />REF. DETAIL A SHEET E570
<br />a,b,c
<br />LOWER CASE LETTER INDICATES SWITCHING
<br />"EMERGENCY EXHAUST" RED NAMEPLATE.
<br />E]<
<br />LOWBAY SPEAKER,
<br />DUTY
<br />COMBINATION STARTER
<br />PUSHBUTTON STOP -START STATION
<br />HORN TYPE
<br />PROVIDE LOW -VOLTAGE SWITCH CONTROL
<br />WIRING AS 3X #18 AWG IN 1/2" MIN. C
<br />3A
<br />CONTROLLER OR MCC
<br />460 VOLT MOTOR (SIZE AS NOTED)
<br />M
<br />MID HEIGHT SPEAKER
<br />HORN TYPE
<br />FROM EACH LOW VOLTAGE SWITCH
<br />TO THE LIGHTING CONTROL PANEL
<br />T
<br />CUBICLE NUMBER
<br />4
<br />208 VOLT OR 240 V MOTOR
<br />CLUSTER HORNS, REF. DETAILS
<br />UNLESS OTHERWISE NOTED.
<br />_
<br />(SIZE AS NOTED)
<br />ON SHEET E571
<br />2$m $M
<br />MOTION SENSOR SWITCH CONTROL
<br />OR
<br />115 VOLT MOTOR (SIZE AS NOTED)
<br />FIRE ALARM
<br />SYSTEM
<br />REF. DETAIL 1A, SHEET E506
<br />FOR ASSEMBLY
<br />®
<br />POWER FACTOR CORRECTION CAPACITOR
<br />F
<br />ELEVATOR ALARM BELL
<br />$m
<br />LUTRON NTHF-40 HI-LUME FLUORESCENT
<br />2
<br />LDC
<br />400 HZ LINE DROP COMPENSATOR CABINET
<br />9<
<br />FIRE ALARM HORN/STROBE, WALL OR CEILING
<br />DIMMING CONTROL AND BALLAST SYSTEM.
<br />STARTER SIZE
<br />W/O TRANSFORMER
<br />/7\
<br />SMOKE DETECTOR, SUBSCRIPT X:XX = DEVICE ADDRESS, $w
<br />REFERENCE DETAIL 2, SHEET E506.
<br />XLDC
<br />400 HZ LINE DROP COMPENSATOR WITH
<br />"D" = DUCT SMOKE DETECTOR
<br />INCANDESCENT DIMMER LUTRON
<br />STEP DOWN TRANSFORMER
<br />�x:xx
<br />HEAT DETECTOR, SUBSCRIPT X:XX =DEVICE ADDRESS
<br />NTLV 600 SERIES
<br />POWER FACTOR
<br />CORRECTION CAPACITOR
<br />CONDUIT NOT BURIED
<br />(INCLUDING ABOVE SUSPENDED
<br />®x:xx
<br />REMOTE RELAY, SUBSCRIPT X:XX = DEVICE ADDRESS
<br />$�
<br />INCANDESCENT DIMMMER, WATTAGE AS
<br />CEILING & UNDER RAISED FLOOR)
<br />�F xxx
<br />MANUAL STATION, SUBSCRIPT X:XX = DEVICE ADDRESS
<br />NOTED. LUTRON MODEL NUMBERS:
<br />NT-1000
<br />HP
<br />- MOTOR HORSEPOWER
<br />BURIED CONDUIT WIRING
<br />❑wF xz
<br />WATERFLOW SWITCH, SUBSCRIPT X:XX = DEVICE ADDRESS,
<br />NT-1500
<br />(UNDERGROUND & IN FLOOR SLAB)
<br />ox
<br />"P" = PRESSURE TYPE, "PD" = PRESSURE TYPE W/DELAY $uw
<br />MAGNETIC LOW VOLTAGE DIMMER.
<br />�
<br />ELECTRICAL POWER
<br />FLEXIBLE METAL CONDUIT
<br />PS x:xx
<br />HI/LO AIR PRESSURE SWITCH
<br />LUTRON P/N NT-1003
<br />``
<br />FILTER
<br />SUBSCRIPT X:XX = DEVICE ADDRESS
<br />$us
<br />MAGNETIC LOW VOLTAGE TOUCH SWITCH.
<br />1
<br />CONDUIT HASH MARK DESIGNATIONS
<br />�z:xx
<br />TAMPER SWITCH (VALVE SWITCH)
<br />LUTRON P/N NTETS-1
<br />CONDUCTOR
<br />SUBSCRIPT X:XX = DEVICE ADDRESS
<br />SINGLE LINE
<br />FUSED SWITCH
<br />_44��PHASE
<br />NEUTRAL CONDUCTOR
<br />GROUND CONDUCTOR
<br />ISOLATED
<br />FATC
<br />FIRE ALARM TERMINAL CABINET
<br />GREEN GROUND CONDUCTOR
<br />FFA-C-Pl
<br />FIRE ALARM CONTROL PANEL
<br />o ulu
<br />TRANSFORMER (DASHED LINE
<br />DISCONNECT SWITCH
<br />CIRCUIT SOURCE
<br />l
<br />INDICATES ELECTROSTATIC
<br />SHIELD)
<br />Y
<br />P
<br />-�
<br />PANEL/CIRCUIT BREAKER NO.(S)
<br />®
<br />GENERATOR
<br />1D6-1/1,3,5
<br />SURGE ARRESTER
<br />O
<br />CONDUIT TURNS DOWN
<br />TRANSFER SWITCH
<br />- 0
<br />CONDUIT TURNS UP
<br />CIRCUIT BREAKER W/
<br />ELECTRICAL OPERATOR
<br />[3-1
<br />DISCONNECT SWITCH
<br />CONDUIT ONLY
<br />E
<br />LT = LONG T.D. TRIP UNIT
<br />/
<br />ST = SHORT _ INSTANT. T RIPRIP NIT
<br />UNIT
<br />INTERLOCK
<br />-E-
<br />EMERGENCY CIRCUIT
<br />LT
<br />Y ❑
<br />GF = GND. FAULT TRIP UNIT
<br />M=MECHANICAL
<br />E=ELECTRICAL
<br />DIAGRAM SYMBOLS
<br />SCHEMATIC
<br />SCHEMATIC
<br />DISCONNECT SWITCH FLOW SWITCH - N.C.
<br />OPENS ON INCREASE IN FLOW
<br />�-
<br />FUSE
<br />a- FLOW SWITCH - N.O.
<br />- -
<br />CIRCUIT BREAKER CLOSES ON INCREASE IN FLOW
<br />L,j
<br />TRANSFORMER TEMPERATURE SWITCH - N.C.
<br />OPENS ON RISING TEMP
<br />GROUND CONNECTION °- TEMPERATURE SWITCH - N.O.
<br />CLOSES ON RISING TEMP
<br />PILOT LIGHT
<br />* INDICATES COLOR LIMIT SWITCH - N.C.
<br />PUSHBUTTON o-- LIMIT SWITCH - N.O.
<br />__o o-
<br />MOMENTARY CONTACT
<br />NORMALLY OPEN RELAYS & COILS
<br />PUSHBUTTON *=TYPE
<br />MOMENTARY CONTACT M=MOTOR STARTER
<br />NORMALLY CLOSED CR=CONTROL RELAY
<br />C=CONTACTOR
<br />OFFS ON
<br />SELECTOR SWITCH R=TIME DELAY OR TIMING
<br />l"
<br />MAINTAINED CONTACT RELAY
<br />TWO POSITION - I kp__ N.O. CONTACT
<br />2
<br />i
<br />-- N.C. CONTACT
<br />SELECTOR SWITCH
<br />- + - 2
<br />MAINTAINED CONTACT
<br />THREE POSITION N.O. - ON DELAY CONTACT
<br />3
<br />N.C. - ON DELAY CONTACT
<br />SOLENOID VALVE
<br />N.O. - OFF DELAY CONTACT
<br />PRESSURE SWITCH +
<br />- N.C.
<br />OPENS ON RISING PRESSURE
<br />� N.C. -OFF DELAY CONTACT
<br />PRESSURE SWITCH - N.O.
<br />CLOSES ON RISING PRESSURE
<br />FLOAT OR LEVEL SWITCH - N.C.
<br />OPENS ON RISING LEVEL
<br />FLOAT OR LEVEL SWITCH - N.O.
<br />CLOSES ON RISING LEVEL
<br />PANEL NOMENCLATURE
<br />XE 3 VO
<br />-1 U D12-1-D
<br />SUFFIX "-D" INDICATES DISTRIBUTION PANEL
<br />[�__SUFFIX
<br />"-1, -2, -3, ETC." IS USED TO INDICATE MULTIPLE
<br />PANELS AT SAME LOCATION WHICH ARE SAME VOLTAGE, FED
<br />FROM SAME VAULT AND LOCATED ON SAME FLOOR
<br />NOTE: IF SUFFIX "-A, -B, -C, ETC." IS BEING USED
<br />INSTEAD- OF "-1, -2, -3, ETC.", THEN CONTINUE USING
<br />SUFFIX LETTERS FOR CLARITY
<br />PANEL LOCATION AT NEAREST COLUMN
<br />LOCATION OF PANEL WHEN NOT ON FIRST FLOOR:
<br />M = MEZZANINE U = 2ND FLOOR
<br />P = PENTHOUSE UT = UTIUDOR
<br />R = Pt PARKING FLOOR V = 3RD FLOOR
<br />S = P2 PARKING FLOOR W = 4TH FLOOR
<br />T = TRUSS LEVEL X = 5TH FLOOR
<br />TN = TUNNEL
<br />SOURCE OF POWER: VAULT NO.
<br />FLIGHTLINE EXAMPLE: VS38 FOR SUBSTATION S38
<br />VOLTAGE AND ASSOCIATED PANEL SYMBOL:
<br />® 4 = 48OV, 3PH, 3W
<br />® 3 = 480Y/277V, 3PH, 4W
<br />v 2 = 208Y/12OV, 3PH, 4W OR 120/24OV, 1PH, 3W
<br />© 5 = 400 HZ, 575Y/331V, 3PH, 4W
<br />© 2 = 400 HZ, 200Y/115V, 3PH, 4W
<br />W-1 I = 28 VDC
<br />PREFIX: (BLANK) = NORMAL POWER PANEL
<br />"I" = ISOLATED GND PANEL
<br />"Z" = 400 HZ PANEL
<br />"XE" = EMERGENCY PANEL
<br />"XL" = LEGALLY REQUIRED STANDBY PANEL
<br />"XS" = OPTIONAL STANDBY PANEL
<br />GENERAL NOTES
<br />1. CONDUIT: 1/2" MINIMUM - TYPE AND SIZE IN ACCORDANCE
<br />WITH PLAN DRAWINGS AND THE SPECIFICATIONS.
<br />2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER,INSULATION
<br />TYPE THHN/THWN, UNLESS OTHERWISE NOTED.
<br />3. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS WHICH DO
<br />NOT HAVE APPROPRIATELY COLORED INSULATION WITH COLOR
<br />TAPE WHEREVER CONDUCTORS ARE ACCESSIBLE. IDENTIFY
<br />INSULATED GROUND CONDUCTORS PER NEC 250-57(b)
<br />EXCEPTION #1,b OR c (USING TAPE). COLOR CODE AS
<br />FOLLOWS:
<br />208Y 1 OV 480Y/277V
<br />A 0 �LCEEFN7TERJSBUS
<br />BIN PNL) BLACK BROWN
<br />B 0 IN PNL) RED ORANGE
<br />C 0 RIGHT BUS IN PNL) BLUE YELLOW
<br />NEUTRAL WHITE GRAY
<br />EQUIPMENT GROUND GREEN GREEN
<br />ISOLATED GROUND GRN/YEL* GRN/YEL*
<br />*GREEN WITH YELLOW TRACER
<br />4. LABEL EACH RECEPTACLE, JUNCTION/OUTLET BOX AND SWITCH
<br />WITH CIRCUIT IDENTIFICATION AS SCHEDULED ON SHEETS E1B
<br />& E1C, USING TYPED SCHEDULED ON SHEETS E1B & E1C,
<br />USING TYPED LABEL.
<br />5. INSTALL NEW OR REVISED PANEL SCHEDULES UPON COMPLETION
<br />OF JOB.
<br />6. PANELS ARE TO BE IDENTIFIED BY LAMINATED PHENOLIC
<br />NAMEPLATES AS DETAILED ON SHEET E1B AND AS SHOWN IN
<br />THE SPECIFICATIONS.
<br />ABBREVIATIONS
<br />AFF
<br />ABOVE FINISHED FLOOR
<br />AHC
<br />ABOVE HUNG CEILING
<br />AL
<br />ALUMINUM
<br />ATS
<br />AUTOMATIC TRANSFER SWITCH
<br />AWG
<br />AMERICAN WIRE GAUGE
<br />CB
<br />CIRCUIT BREAKER
<br />C.O, CO
<br />CONDUIT ONLY
<br />CRU
<br />COMPUTER ROOM UNIT
<br />DED
<br />DEDICATED
<br />DP
<br />DISTRIBUTION PANEL BOARD
<br />EF
<br />EXHAUST FAN
<br />EMCS
<br />ENERGY MANAGEMENT CONTROL SYSTEM
<br />EMT
<br />ELECTRICAL METALLIC TUBING
<br />EPO
<br />EMERGENCY POWER OFF
<br />ES
<br />EPO SWITCH
<br />FACP
<br />FIRE ALARM CONTROL PANEL
<br />FAR
<br />FIRE ALARM RELAY
<br />FATC
<br />FIRE ALARM TERMINAL CABINET
<br />FDP
<br />FIRE DETECTION PANEL
<br />FVNR
<br />FULL VOLTAGE, NON -REVERSING
<br />GFI
<br />GROUND FAULT INTERRUPTER
<br />GND, G
<br />GROUND
<br />HP
<br />HORSEPOWER
<br />IMC
<br />INTERMEDIATE METAL CONDUIT
<br />LV
<br />LOW VOLTAGE
<br />M. BKR.
<br />MAIN BREAKER
<br />MCC
<br />MOTOR CONTROL CENTER
<br />MCM
<br />MILLION CIRCULAR MILS
<br />MLO
<br />MAIN LUGS ONLY
<br />NACB
<br />NON -AUTOMATIC CIRCUIT BREAKER
<br />NEC
<br />NATIONAL ELECTRICAL CODE
<br />N/A
<br />NOT APPLICABLE
<br />NC
<br />NORMALLY CLOSED
<br />NO
<br />NORMALLY OPEN
<br />PA
<br />PAGING SYSTEM
<br />PH
<br />PHASE
<br />PNL
<br />PANEL
<br />PVC
<br />POLY -VINYL CHLORIDE (CONDUIT)
<br />RF
<br />RETURN FAN
<br />RVNR
<br />REDUCED VOLTAGE, NON -REVERSING
<br />SRP
<br />SMOKE REMOVAL PANEL
<br />SWBD
<br />SWITCHBOARD
<br />SWGR
<br />SWTTCHGEAR
<br />SF
<br />SUPPLY FAN
<br />ST
<br />SHUNT TRIP CIRCUIT BREAKER
<br />01.13.15
<br />TO BE DETERMINED
<br />T.D.
<br />TIME DELAY
<br />THHN
<br />WIRE INSULATION TYPE REFER TO N.E.C.
<br />THWN
<br />WIRE INSULATION TYPE REFER TO N.E.C.
<br />T/S
<br />TWISTED AND SHIELDED PAIR
<br />UH
<br />UNIT HEATER
<br />WP
<br />WEATHER PROTECTED
<br />XFMR
<br />TRANSFORMER
<br />_ AF
<br />AMPS -FRAME
<br />AT
<br />AMPS -RIP
<br />*NOTE: SEE SHEET
<br />E506 FOR
<br />ADDITIONAL FIRE ALARM 1
<br />ABBREVIATIONS. \
<br />/■
<br />REVISION
<br />BY
<br />I APPROVED
<br />DATE
<br />ISYM
<br />REVISION
<br />BY
<br />I APPROVED
<br />DATE
<br />ACCEPTABILITY
<br />DRAWN
<br />DAlE
<br />SUBTITLE
<br />EVERETT FIRE PANEL REPLACEMENT W2640474
<br />SAZAN/JW
<br />03.04.20
<br />THIS DESIGN AND/OR
<br />ELECTRICAL LEGEND & ABBREVIATIONS
<br />SHOP DRAWINGS
<br />AGOW/HG
<br />11.13.20
<br />�OE/A/G ®
<br />m
<br />SPECIFICATION IS
<br />APPROVED
<br />I
<br />TITLE EVERETT FIRE PANEL REPLACEMENT
<br />APPROVED BY
<br />DE-1
<br />DATE
<br />`G:�n"�
<br />CHECKED
<br />BUILDING 40-032
<br />i
<br />APPROVED
<br />ELECTRICAL MASTER EVERETT, WA.
<br />MAN
<br />GOW
<br />DATE
<br />A 11.13.20
<br />EO
<br />W2640474
<br />40-032-EO
<br />
|