(E) POTTER IPA-4000 <br /> The Symbol of Protection Fire Alarm Control Panel <br /> SLC Features RA-6075R—2 x 16 LCD annunciator with a key pad in a locked <br /> The Potter protocol is a digital protocol with a proven design for metal enclosure. <br /> reliability and noise immunity.The system does not require special RA-6500R(F)—4 x 40 LCD annunciator with a key pad in a locked <br /> cable or conductors for connection of the Signaling Line Circuit metal enclosure.Flush mount version available. <br /> as long as the cable is compliant with NFPA 70 and NFPA 72. LED-16(F)—16 LED annunciator with common indicators in a <br /> The system allows for Class A or Class B installations as well as locked metal enclosure.Flush mount version available. <br /> "T-Taps."Each loop is capable of 127 points,with a max wiring PSN-1000(E)—10 amp,remote intelligent power supply with <br /> distance of 10,000 ft. 6 NACs,2 Inputs and a P-Link repeater.This panel is listed in <br /> Sensor Features conjunction with the IPA-4000 as releasing circuits. <br /> The sensors through the fire alarm control panel provide a real CA-6500—Class A convertor that converts the SLC,NACs and <br /> time status as to the condition of the system.The smoke detector P-Link connection <br /> sensitivity,heat detector temperature level and drift compensation UD-2000—UL listed,Dual line telephone alarm communicator <br /> are all programmable options.The system also allows for a day/night DRV-50—LED driver expander,used to connect up to 50 LEDs in a <br /> mode where the panel automatically adjusts the sensitivity depending graphic display <br /> on the time of day.To assist in the reduction of false alarms,the FCB-1000—Fire communication bridge,provides remote mounting <br /> smoke detectors also have a maintenance warning that sends a trouble of the Ethernet connection <br /> signal when a detector is dirty to the point that it can no longer FIB-1000—Fiber interface module,used to extend P-Link to multi- <br /> maintain the programmed sensitivity. mode fiber(2 required) <br /> User Interface RLY 5—Relay module,provides 5 form C relay contacts rated at 3.0 <br /> The fire alarm control panel has a 4 x 40 LCD display to provide amps 24VDC/125AC <br /> information to the system status.The keypad has navigation keys SPG-1000—Serial parallel gateway,allows for the connection to a <br /> to allow manipulation of the Menu on board the panel.The panel is serial or parallel printer <br /> shipped standard with the following LEDs: The FIB-1000,FCB-1000 and the SPG-1000 may be installed in the <br /> • AC Power-Green stacker bracket or ordered with the optional rack mount enclosure. <br /> • Alarm-Red MC-1000 Multi-Connect allows up to sixty-three IPA series panels to <br /> share a single reporting technology. <br /> • Earth Fault-Amber IDC-6—Initiating device circuit provides 6 programmable inputs <br /> • Supervisory-Amber AE-2—Two card expansion cabinet <br /> • Silenced-Amber AE-8—Eight card expansion cabinet <br /> • Trouble-Amber AE-14—Fourteen card expansion cabinet <br /> • Pre-Release-Amber Ethernet/I.P. Connection <br /> • Release-Red The IPA-4000 is shipped standard with an Ethernet connection. <br /> This connection is the programming port and may be connected <br /> The common buttons include a Silence,Reset,Acknowledge,and to a building Wide Area Network(WAN)or Local Area Network <br /> Drill.All of the buttons are accessible once the locked door is (LAN).Once connected to the Internet,the panel may be selectively <br /> opened. programmed to e-mail alarm conditions,trouble conditions, <br /> P-Link supervisory conditions,test,Event History and detector status.An <br /> e-mail may be sent to the panel and the panel will e-mail the event <br /> The IPA-4000 has a proprietary communication protocol that history,detector status,configuration file or server status to an <br /> communicates through a RS-485 connection to field devices.Up authorized E-mail account.In addition,reminders maybe set to send <br /> to 64 devices may be connected to a single P-Link connection.The <br /> an e-mail for service,testing or other conditions. <br /> P-Link includes the communication terminals and regulated 24 VDC <br /> connection for the field devices.The field devices may be any of the In addition,the Ethernet connection is UL listed as an IP <br /> following: communicator.The IP communicator is listed to report to the UL <br /> PAD100-SLCE-Analog/Addressable loop expansion module listed Sur-Gard III IP receiver.The IP communicator replaces the <br /> (maximum of 31 per IPA-4000) traditional less reliable alarm communicator transmitter that utilized <br /> telephone lines.The IP communicator is an active method of <br /> connection and communication to the monitoring station. <br /> Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br /> 8830102-REV J 5/23 PAGE 4 OF 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.