LEGEND <br /> 7 7 8 9 9 1 0 1 1 1 1 SEE SHEET EO FOR LEGEND AND ABBREVIATIONS. <br /> B <br /> I I I I <br /> II <br /> B I <br /> GENERAL NOTES <br /> UV3-8A TAMPER L1:031 I'> SEE 2/E506-1 FOR ELEVATOR 30 FIRE ALARM RISER <br /> DIAGRAM <br /> I I I <br /> STAIR 1 <br /> J_LL1 <br /> SV3-8 TAMPERS1 <br /> L1:022 <br /> VS <br /> 1/2 C, 2#14 ELEV <br /> E <br /> SV3-6 TAMPER VS SV3-8 1 O S 3 1 <br /> C L1:016 WFWF ISO TAMPER QUIET ROOM 4 <br /> PROJECT ROOM W RKSTATIONS SV3-6 pSP WF PD ° 2D9 SM ANN <br /> EV 30 LEY LVL1 L1:040 1 REFERENCE DRAWING S <br /> L1:024 <br /> 1 7 11D8 WF PRESSURE S6-8GRACE -- I E506 FIRE ALARM SYSTEM DETAILS <br /> CONFERENCE <br /> L1:017 WE PRESSURE 3D9.023 1 5 E506-1 FIRE ALARM RISER DIAGRAMS <br /> 2 SV3-6 HI/LO AIR I13D10 <br /> 1 L1:018 TO EACH <br /> I PROJECTROOMFIN <br /> ANCE <br /> 11 D9 <br /> ° CONF <br /> 14D9 <br /> = I 1/2"C UP i <br /> CONSTRUCTION NOTES <br /> PROJECT ROOM PROVIDE MONITORING DEVICES ON EXISTING SPRINKLER <br /> j 11 D7 PHONE ROOM RISER. CONNECT TO NEW BUILDING FACP. UTILIZE <br /> 16D9 I EXISTING INFRASTRUCTURE. PROVIDE ADDITIONAL CONDUIT <br /> AND CONDUCTORS AS REQUIRED. SEE DETAIL 1/E506 <br /> PHONE ROOM 1/2"C, 6#14 UP FOR INSTALLATION NOTES. <br /> ELEC <br /> CONFERENCE <br /> Fl—5D9 <br /> I REPRO F --1 CAFE <br /> T-Tn TI 14 5D10 I �CONNECT EXISTING DEVICE TO NEW BUILDING FACP. <br /> 1 11 C8 I UTILIZE EXISTING INFRASTRUCTURE. PROVIDE ADDITIONAL <br /> I <br /> EAR PROJECTION 11C9 GALLERY CONDUIT AND CONDUCTORS AS REQUIRED. <br /> ( IIIIIIII I I <br /> 11C7 WORKSTATION L11u111 =J 12D10 PROVIDE DEVICE, TYPE AS SHOWN, AND CONNECTION TO <br /> NEW BUILDING FACP. UTILIZE EXISTING INFRASTRUCTURE. <br /> 12C7 I D PROVIDE ADDITIONAL CONDUIT AND CONDUCTORS AS <br /> w l I N REQUIRED. <br /> I I LIBRARY w <br /> 12C8 w ®PROVIDE ADDRESSABLE SMOKE DETECTOR AND <br /> N CONNECTION TO NEW BUILDING FACP. PROVIDE <br /> o l Z ADDITIONAL CONDUIT AND CONDUCTORS AS REQUIRED. <br /> zUTILIZE EXISTING INFRASTRUCTURE. <br /> z [j::�' PROVIDE REMOTE ANNUNCIATOR, CONDUIT, CONDUCTOR <br /> P JECT ROOM = I o AND CONNECTION TO BUILDING FACP. <br /> U <br /> 0 13C7 <br /> ° CONF ° I o <br /> N w l 3C9 <br /> J CO <br /> ° 2NF <br /> tz <br /> =I ° 12 <br /> I I v <br /> � I = <br /> I <br /> o I <br /> I I <br /> Ile 1 2 3 4 5 5' 6 7 7' 8 9 9'10 11 1 1213 3 14 15 16 17 <br /> __STI o; X-RAY VAULT E <br /> ---- -----a, I <br /> '------ 12610 <br /> ----y - ---- 'r----- 1 1E260 1E261 1E262 1E263 1E264 D <br /> a CONF -_-_-_-;I--_-_-- <br /> c <br /> 5 I <br /> STORAGE ----;----- o WORKSTATIONS r----iL 1 1E265 1E266 1E267 1E268 1E269 B <br /> 14C9 r---- <br /> 14C7 ----iL---- 14C8 - ----o <br /> O i A <br /> , <br /> , <br /> N <br /> - - L - - G KEY PLAN <br /> /2"C, 6#14 0 �I <br /> SCALE:NONE N <br /> 0 <br /> TRANSPORTATION AISLE 8 4 0 4 8 16 <br /> -12B8 <br /> -- -- -- -- -- -- -- -- -- --—FOR -- - -- -- -- -- -- -- -- -- SCALE: 1/8=1'-0.. <br /> MATCH LINE - TI DATION SEE 1 E267 <br /> PARTIAL PLAN <br /> VIEW <br /> SCALE: 1/8" - 1'-0" N <br /> 3 DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ti SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY <br /> ~ A EVERETi FIRE PANEL REPLACEMENT- XX W2640474 SAZAN/ZO 03.24.23 THIS DESIGN AND/OR <br /> QHEQKED FIRE ALARM SYSTEM PLAN-FIRST FLOOR 30397493 09.19.23 <br /> SPECIFICATION IS APPROVED SHEET SEQUENCE NO. <br /> ENGINEER TITLE 1 E262 <br /> 8 B SHOP DRAWINGS 30397493 AGOW/JS 09.19.23 APPROVED BY DEPT. DATE EVERETT FIRE PANEL REPLACEMENT <br /> oBOE/A/G CHECKED <br /> ZZ APPROVED BUILDING 40-003 <br /> JOB N0. COMP N0. <br /> 30397493 <br /> o APPROVED ELECTRICAL COL. C-E/7'-11' EVERETT, WA. Dwc No. 40-003-1E262 <br />