Laserfiche WebLink
B LEGEND <br /> Z 3 4 SEE SHEET EO FOR LEGEND AND ABBREVIATIONS. <br /> MATCH LINE - FOR CONTINUATION SEE 117260 <br /> -- -- -- - -- -- -- -- - -- -- -- -- -- -- -- -- -- -- --� <br /> I TRANSPORTATION AISLE I I <br /> 11132 <br /> GENERAL NOTES <br /> I <br /> BULK QA AREA <br /> 1281 <br /> \ I <br /> I <br /> 1"C, 10#14 <br /> REFERENCE DRAWINGS <br /> B E506 FIRE ALARM SYSTEM DETAILS <br /> _ B E506-1 FIRE ALARM RISER DIAGRAMS <br /> ----- ------------- <br /> I <br /> I <br /> I 1C I I I <br /> I 2 2 2 <br /> w co <br /> B <br /> o w <br /> CONVEYOR <br /> 11A2 0 ¢ o <br /> DATA ENTRY z I CONSTRUCTION NOTES <br /> 2A1CD I CD PROVIDE FIRE ALARM TERMINAL CABINET IN PLACE OF <br /> ADT FOCUS PANEL. PROVIDE CONNECTIONS BETWEEN <br /> o EXISTING AND NEW FIRE ALARM CIRCUITS. <br /> CONNECT EXISTING DEVICE TO NEW BUILDING FACE. <br /> z UTILIZE EXISTING INFRASTRUCTURE. PROVIDE ADDITIONAL <br /> B CONDUIT AND CONDUCTORS AS REQUIRED. <br /> x <br /> CONVEYOR a <br /> PROVIDE MONITORING DEVICES ON EXISTING SPRINKLER <br /> 11A1 RISER. CONNECT TO NE <br /> BUILDING <br /> WF PRESSURE I NFRASTRUCTURE. PROVIDEADDONALPUTILIZE STING <br /> CONDUIT <br /> 2 SV3-1 2 _1:008 2 I CONDUCTORS AS REQUIRED. SEE DETAIL 1/E506 FOR <br /> WE PRESSURE INSTALLATION NOTES. <br /> 11:002 WF Ph!WF PD 1"C 24#14 <br /> 2 SV3-1 `s vs I A <br /> HI/LO AIR _1:003 1 <br /> /2"C, 2#14 SV3-3 <br /> TO EACH WF ISO TAMPER 3 <br /> o SV3-1 TAMPER L1:009 <br /> _1:001 <br /> SV3-3 TAMPER-< <br /> 1/22C', 2#14�� L1:007 <br /> 1/2"C, 2#14 <br /> I <br /> I <br /> 7' 8 9 111 11 1 12 13 3 14 15 16 17 <br /> E <br /> 1 E260 1E261 1E262 1E263 11264 0 <br /> 5 <br /> C <br /> wo 1E265 1E266 1E267 1E268 1E269 B <br /> I A <br /> PARTIAL PLAN VIEWKEY <br /> KI <br /> SCALE: 1/8" 1'-0" C SCALE:NONE AN <br /> 8 4 0 4 8 16 <br /> SCALE: 1/8" <br /> 3 <br /> O <br /> 3 DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL DATE <br /> ti SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY <br /> ~ A EVERET[ FIRE PANEL REPLACEMENT- XX W2640474 SAZAN/ZO 03.24.23 THIS DESIGN AND/OR <br /> CHECKED <br /> FIRE ALARM SYSTEM PLAN-FIRST FLOOR 30397493 09.19.23 <br /> SPECIFICATION IS APPROVED SHEET SEQUENCE NO. <br /> ENGINEER TITLE 117265 <br /> 8 B SHOP DRAWINGS 30397493 AGOw JS 09.19.23 APPROVED BY DEPT. DATE EVERETT FIRE PANEL REPLACEMENT <br /> o / BOE/A/G \ CHECKED <br /> ZZ APPROVED BUILDING 40-003 <br /> JOB N0. COMP N0. <br /> 30397493 <br /> o APPROVED ELECTRICAL COL. A-C/1-4.5 EVERETT, WA. DWG No. 40-003-1E265 <br />