*SPRINKLER VALVE WATERFLOW ALARM <br /> MONITORING AND WATERFLOW ISOLATION FIRE ALARM ABBREVIATIONS LEGEND <br /> TO SPRINKLERS SUPERVISION EQUIPMENT INSTALLATION <br /> WATERFLOWSEE SHEET EO FOR SYMBOLS AND ABBREVIATIONS. <br /> PRESSURE SWITCH ALT SECONDARY OR ALTERNATE ELEVATOR RECALL NAC NOTIFICATION APPLIANCE CIRCUIT OR POWER SUPPLY <br /> WITH BUILT—IN BEAM DET BEAM DETECTOR OS&Y OUTSIDE SCREW AND YOKE VAVLE G F N F RA L N O T F S <br /> RETARD/DELAY, CDR COMPUTER/NETWORK/DATA/IDF ROOM PD PUMP DISCHARGE VALVE <br /> WFSR-F B COL COLUMN PH PENTHOUSE 1. ELECTRICAL CONTRACTOR SHALL INSTALL <br /> POTTER <br /> # COMM FAIL COMMUNICATION FAILURE PIV POST INDICATOR VALVE ENCLOSURE(S) AND POWER. <br /> (ALARM) CTRL CONTROL POWER FAIL FACP POWER FAILURE <br /> 1 CW CATWALK PREACT PREACTION SYSTEM 2. SPRINKLER RISER PIPING CONFIGURATION SHOWN IS <br /> DMPR DAMPER PRI PRIMARY DIAGRAMMATIC AND DOES NOT NECESSARILY <br /> DD DUCT SMOKE DETECTOR PS PUMP SUPPLY VALVE REPRESENT ANY SPECIFIC INSTALLATION. <br /> DIESEL DIESEL PWR POWER <br /> FP FIRE PUMP RF ROOF CELLULAR COMMUNICATOR EQUIPMENT REPRESENTED <br /> TO WATER ELEC ELECTRICAL; ELECTRICAL ROOM RLY RELAY ON THIS SHEET IS OF A SPECIFIC, APPROVED, <br /> MOTOR GONG ELEV ELEVATOR SEC SECTION VALVE MANUFACTURER AND MODEL. INSTALLATION WILL VARY <br /> WATER PRESSURE GAUGE _ _ J EPP EXCESS PRESSURE PUMP SHUNT SHUNT TRIP DEPENDING ON APPROVED FINAL EQUIPMENT <br /> (SYSTEM PRESSURE) FACP FIRE ALARM CONTROL PANEL SMK SMOKE DETECTOR SELECTIONS. DETAILS AND CONSTRUCTION NOTES <br /> ALARM LINE 1 WATERFLOW ELEV FF HAT LIGHT FIRE FIGHTER HAT LIGHT IN A ELEVATOR STL STALL SHALL APPLY TO ANY EQUIPMENT SELECTED. <br /> ISOLATION ISOLATION FLR FLOOR STROBE STROBE, HORN OR ANY NOTIFICATION DEVICE ® <br /> (OPEN) VALVE, 9 TAMPER SWITCH, FM FIRE MAIN VALVE SUPER SUPPRESSION THIS SPECIFIC EQUIPMENT IS OPTIONAL AND MAY NOT <br /> APOLLO POTTER #RBVS HEAT HEAT DETECTOR SUPV SUPERVISORY NECESSARILY BE REQUIRED. 24VDC POWER MAY BE <br /> BY-PASS LINE #94A-103-27 (SUPERVISORY) INTDEV INTERFACE DEVICE, MONITORING OR CONTROL SV SPRINKLER VALVE DIRECTLY FED FROM THE BUILDING FACP TO THE <br /> L — — — — — ISO ISOLATION VALVE TAMPER TAMPER SWITCH CELLULAR COMMUNICATOR PANEL FOR SPECIFIC <br /> KITCHEN KITCHEN TL300 TL300 TYCO COMMUNICATION DEVICE EQUIPMENT SHOWN. <br /> L BATT LOW BATTERY TRBL TROUBLE <br /> L FUEL LOW FUEL (FIRE PUMP DIESEL TANK IS BELOW 50% FILLED) UV UNIT VALVE 5. ALL WIRING SHALL BE DRESSED AND TRAINED IN A <br /> CHECK VALVE RETARD LEY LOBBY VLV VALVE WORKMANLIKE MANNER. <br /> ° CHAMBER LRD LOW RATE DISCHARGE WF WATERFLOW SWITCH <br /> WATER PRESSURE GAUGE CHECK DRAIN MAN PULL MANUAL PULL STATION ZN ZONE 6. ALL WIRES SHALL BE LABELED WITH WIRE ID. <br /> VALVE MECH MECHANICAL ROOM <br /> (SUPPLY PRESSURE) OPEN (CLOSED) 7. ALL INCOMING POWER WIRING SHALL BE IN CONDUIT. <br /> ® L J B CONSTRUCTION NOTES (CONT. <br /> OS&Y TAMPER 8. ALL PENETRATIONS TO FIRE ALARM CONTROL PANEL <br /> SWITCH WATER BY—PASS TEST PROVIDE LINE SIZF BALL VALVE WITH LOCKABLE AND CELLULAR ENCLOSURES SHALL BE IN <br /> (SUPERVISORY) VALVE (CLOSED) STRAINER HANDLE, TYPE AS NOTED, ON ALARM LINE UPSTREAM ACCORDANCE WITH MANUFACTURER'S <br /> DRIP OF ALARM SWITCH. FIELD VERIFY CORRECT SIZE. INSTRUCTIONS. <br /> UP COMM & SIGNAL (PHONE & TRBL CKT) REFERENCE DRAWINGS <br /> I i mil p 10 PROVIDE TAMPER SWITCH ON ISOLATION VALVE AS <br /> FIRE ALARM A EE MONITORED BY JCI AND SHOWN. <br /> CONTROL C SIGNAL SENT TO CENTRALGONSTRUGTION NOTES <br /> PANEL T BOEING FIRE DEPARTMENT WVIDE WATERFLOW PRESSURE SWITCH WITH ADJUSTABLE <br /> DELAY. PROVIDE CELLULAR DIALER, COMPATIBLE WITH AT&T <br /> OS&Y VALVE (FACE) <br /> *TWO SEPARATE PATHWAYS FOR CELLULAR SERVICE, AND MOUNT ADJACENT TO THE <br /> CONTROL (OPEN) D COMM AND POWER, AS SHOWN. 12. CONFIRM SINGLE ISOLATION VALVE IS INSTALLED ON BUILDING FACP. CONFIGURE DIALER TO PROVIDE SOLE <br /> CHECK 24VDC POWER WATERFLOW SENSING LINE, WHERE EXISTING PATH COMMUNICATION. <br /> VALVE FIRE ALARM CABLING INSTALLATIONS HAVE MORE THAN ONE (1) VALVE, <br /> HORNS BELLS COORDINATE REMOVAL OF ADDITIONAL VALVE(S) WITH PROVIDE (1) CONDUIT PENETRATION FOR PHONE AND <br /> S SMOKE DETECTOR, BOEING CONSTRUCTION MANAGER. FIRE ALARM CONNECTIONS. WIRE AS SHOWN. PROVIDE <br /> PULL STATION, WATER & STROBES ADDRESSABLE MODULE AS NECESSARY TO PROVIDE <br /> *NOTE: DRAIN FLOW & TAMPER 13. COORDINATE WITH FIRE SPRINKLER CONTRACTOR FOR GENERAL TROUBLE ALARM FROM CELLULAR DIALER TO <br /> WATER SUPPLY PIPE SWITCHES INSTALLATION OF DEVICES AND PIPING MODIFICATIONS. BUILDING FACP. <br /> LIMIT OF ONE (1) ISOLATION <br /> VALVE ON ALARM SENSING LINE. <br /> 3 PROVIDE (1) CONDUIT PENETRATION FOR 24/12VDC <br /> SPRINKLER RISER WATERFLOW PRESSURE SWITCH WZDELAY DETAIL- � FIRE ALARM SYSTEM SIGNAL- AND COMMUNICATIONS OVERVIEW � POWER SUPPLY. PROVIDDE"POW R AND WIRE SHOW. <br /> SCALE: NONE E506 SCALE: NONE E506 MAINTAIN MANUFACTURER REQUIRED 1/4" SEPARATION <br /> BETWEEN POWER AND COMMUNICATION WIRING. <br /> ® PROVIDE PHENOLIC LABEL, WHITE LETTERING, RED <br /> BACKGROUND, THAT READS: "FIRE ALARM CELLULAR <br /> DIALER" <br /> 6 5 PEM POWER CABLE STEP 1: VERIFY SIGNAL STRENGTH AT PROPOSED LOCATION FOR CELLULAR COMMUNICATOR PANEL WHERE INDICATED 5 PROVIDE CELL ANTENNA AND EVALUATE FIELD SIGNAL <br /> B (SUPPLIED WITH PEM ON DRAWINGS. IF ACCEPTABLE SIGNAL STRENGTH IS ACQUIRED, SKIP TO STEP 5. � <br /> STRENGTH INA ANTENNA <br /> NCL WITH DETAIL FIELD <br /> SI. INSTALL <br /> STEP 2: IF ORIGINALLY PROPOSED LOCATION IS INADEQUATE, FIELD TEST *SIGNAL STRENGTH WITHIN A 20FT RADIUS CONDUIT AND EXTENDED ANTENNA CABLE AS NECESSARY <br /> TO IDENTIFY LOCATIONS) SUITABLE FOR INSTALLATION OF REMOTE/EXTERNAL CELLULAR ANTENNA. TO REMOTE MOUNT ANTENNA IF COVERAGE IS NOT <br /> r � � COORDINATE THE FINAL ANTENNA LOCATION WITH BOEING AND SPACE USERS (IF IMPACTED) FOR APPROVAL SUITABLE AT FRCP LOCATION. UPDATE BOM WITH <br /> 33/4"C - 2#14THHN,1#14G PRIOR TO ROUGH-IN AND SKIP TO STEP 4. SELECTED CABLE LENGTH AND PROVIDE REDLINES TO <br /> 4BOEING ENGINEER. <br /> STEP 3: PROPOSE ALTERNATE LOCATION FOR CELLULAR PANEL. COORDINATE WITH BOEING AND SPACE USERS FOR <br /> ®FACP EVT-FA-40-03 TG-PEM L POTENTIAL LOCATIONS, PREFERABLY NEAR ORIGINAL LOCATION. IF ANTENNA IS REQUIRED FOR ALTERNATE © FOR REMOTE INSTALLATIONS PROVIDE PHENOLIC LABEL, <br /> (BY FIRE ALARM VENDOR) LOCATION GO TO NEXT STEP, OTHERWISE SKIP TO STEP 5. WHITE LETTERING, RED BACKGROUND, THAT READS: "FIRE <br /> L- TG-7 ES STEP 4: LOCATE AND PROVIDE EXTERNAL CELLULAR ANTENNA, EXTERIOR MOUNTING BRACKET AND COAXIAL CABLE ALARM CELLULAR ANTENNA" <br /> FROM CELLULAR COMMUNICATOR PANEL TO THE ANTENNA. THE ANTENNA AND PANEL SHOULD BE LOCATED 7 POST COMMUNICATOR SETTINGS AND CELLUAR PHONE <br /> R WITHIN BOLT OF EACH OTHER. NUMBER INSIDE CELL ENCLOSURE. PROVIDE PRINTED <br /> 3 STEP 5: PROVIDE 24VDC POWER, MONITORING CIRCUIT, AND TELEPHONE LINE TO CELLULAR COMMUNICATOR PANEL LABEL, HANDWRITTEN INFORMATION IS NOT ACCEPTABLE. <br /> T FROM BUILDING FACP. PROVIDE 24VDC:12VDC VOLTAGE REGULATOR AS NECESSARY. PROVIDE SETTINGS AND CELLULAR INFORMATION TO <br /> STEP 6: PROVIDE REQUIRED SET-UP, PROGRAMMING AND TESTING OF CELLULAR COMMUNICATOR EQUIPMENT PER BOEING ENGINEER. <br /> DC STC2 STC1TRIP BATT AC THE MANUFACTURER'S INSTRUCTIONS. CELLULAR DIALER SHALL BE CONFIGURED AND INSTALLED AS A SOLE ® <br /> PATH FOR FIRE COMMUNICATIONS. PROVIDE PHENOLIC LABEL, INSTALL AND CENTER ON <br /> 2 1 2 3 4 5 6 1 2 3 1 2 G UPPER ENCLOSURE DOOR WITH FACP AND POWER <br /> Owl 0� STEP 7: WHERE CELLULAR COMMUNICATOR PANEL IS INSTALLED REMOTELY OF BUILDING FACP, PROVIDE CIRCUIT IDENTIFICATIONS. LABELS SHALL HAVE WHITE <br /> ADDRESSABLE SMOKE DETECTION, MONITORED BY BUILDING FACP, AT THE CELLULAR COMMUNICATOR PANEL. LETTERING AND RED BACKGROUND. <br /> RED EOL(AS NEEDED) <br /> *ACCEPTABLE SIGNAL STRENGTH SHALL BE DETERMINED BY MANUFACTURER'S SPECIFICATIONS AND LOCAL AHJ <br /> ORDINANCES. <br /> AV <br /> 3/4"C — (1) PHONE CABLE, <br /> (1) 2 CONDUCTOR FPL OR �"CELLULAR COMMUNICATOR INSTALLATION SEQUENCE 4Irl <br /> APPROVED EQUAL <br /> E E506 <br /> LIRE ALARM SYSTEM COMMUNICATIONS DETAIL G.O� <br /> SCALE: NONE 2E262 E506 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWNA SUBTITLE CURRENT REVISION SYMBOL DATE <br /> HIS DESIGN AND/OR <br /> CHECKED FIRE ALARM SYSTEM DETAILS 30397493 B 09.19.23 <br /> A EVERETT FIRE PANEL REPLACEMENT— XX W2640474 SAZAN/ZO 03.24.23 S,TlIl DISI IS APPROVED SHEET SEQUENCE Na. <br /> Q�BOE//VG m <br /> B SHOP DRAWINGS 30397493 AGOW/JS 09 1923 APPROVED BY DEPT. DATE NGIUEIR TITLE EVERETT FIRE PANEL REPLACEMENT <br /> CHECKED E506 <br /> APPROVED BUILDING 40-003 <br /> APPROVED ELECTRICAL EVERETT, WA. DWG NO. 40-003—E506 <br />